참고문헌
- Garber DA, Belser UC. Restoration-driven implant placement with restoration-generated site development. Compend Contin Educ Dent 1995;16:796, 798-802, 804.
- Becker CM, Kaiser DA. Surgical guide for dental implant placement. J Prosthet Dent 2000;83:248-51. https://doi.org/10.1016/S0022-3913(00)80018-9
- D'Souza KM, Aras MA. Types of implant surgical guides in dentistry: a review. J Oral Implantol 2012;38:643-52. https://doi.org/10.1563/AAID-JOI-D-11-00018
- Marchack CB. CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient. J Prosthet Dent 2007;97:389-94. https://doi.org/10.1016/S0022-3913(07)60028-6
- Park C, Raigrodski AJ, Rosen J, Spiekerman C, London RM. Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study. J Prosthet Dent 2009;101:372-81. https://doi.org/10.1016/S0022-3913(09)60080-9
- Lee SL, Kim HJ, Son MK, Chung CH. Anthropometric analysis of maxillary anterior buccal bone of Korean adults using cone-beam CT. J Adv Prosthodont 2010;2:92-6. https://doi.org/10.4047/jap.2010.2.3.92
- Koop R, Vercruyssen M, Vermeulen K, Quirynen M. Tolerance within the sleeve inserts of different surgical guides for guided implant surgery. Clin Oral Implants Res 2013;24:630-4. https://doi.org/10.1111/j.1600-0501.2012.02436.x
- Aalam AA, Nowzari H, Krivitsky A. Functional restoration of implants on the day of surgical placement in the fully edentulous mandible: a case series. Clin Implant Dent Relat Res 2005;7:10-6. https://doi.org/10.1111/j.1708-8208.2005.tb00041.x
- Barone A, Rispoli L, Vozza I, Quaranta A, Covani U. Immediate restoration of single implants placed immediately after tooth extraction. J Periodontol 2006;77:1914-20. https://doi.org/10.1902/jop.2006.060072
- Holst S, Blatz MB, Eitner S. Precision for computer-guided implant placement: using 3D planning software and fixed intraoral reference points. J Oral Maxillofac Surg 2007;65:393-9. https://doi.org/10.1016/j.joms.2006.10.050
- Youk SY, Lee JH, Park JM, Heo SJ, Roh HK, Park EJ, Shin IH. A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template. J Adv Prosthodont 2014;6:395-405. https://doi.org/10.4047/jap.2014.6.5.395
- Stumpel LJ 3rd. Cast-based guided implant placement: a novel technique. J Prosthet Dent 2008;100:61-9. https://doi.org/10.1016/S0022-3913(08)60140-7
- Noharet R, Pettersson A, Bourgeois D. Accuracy of implant placement in the posterior maxilla as related to 2 types of surgical guides: a pilot study in the human cadaver. J Prosthet Dent 2014;112:526-32. https://doi.org/10.1016/j.prosdent.2013.12.013
- Cassetta M, Di Mambro A, Di Giorgio G, Stefanelli LV, Barbato E. The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study. Clin Implant Dent Relat Res 2015;17:580-8. https://doi.org/10.1111/cid.12120
- Van Assche N, Quirynen M. Tolerance within a surgical guide. Clin Oral Implants Res 2010;21:455-8. https://doi.org/10.1111/j.1600-0501.2009.01836.x
- Widmann G, Bale RJ. Accuracy in computer-aided implant surgery-a review. Int J Oral Maxillofac Implants 2006;21:305-13.
- D'haese J, Van De Velde T, Elaut L, De Bruyn H. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. Clin Implant Dent Relat Res 2012;14:293-303. https://doi.org/10.1111/j.1708-8208.2009.00255.x
- Block MS, Chandler C. Computed tomography-guided surgery: complications associated with scanning, processing, surgery, and prosthetics. J Oral Maxillofac Surg 2009;67:13-22.
- Vercruyssen M, Hultin M, Van Assche N, Svensson K, Naert I, Quirynen M. Guided surgery: accuracy and efficacy. Periodontol 2000 2014;66:228-46. https://doi.org/10.1111/prd.12046
- Cassetta M, Di Mambro A, Giansanti M, Stefanelli LV, Cavallini C. The intrinsic error of a stereolithographic surgical template in implant guided surgery. Int J Oral Maxillofac Surg 2013;42:264-75. https://doi.org/10.1016/j.ijom.2012.06.010
- Verhamme LM, Meijer GJ, Boumans T, de Haan AF, Berge SJ, Maal TJ. A clinically relevant accuracy study of computer-planned implant placement in the edentulous maxilla using mucosa-supported surgical templates. Clin Implant Dent Relat Res 2015;17:343-52. https://doi.org/10.1111/cid.12112
- Van de Wiele G, Teughels W, Vercruyssen M, Coucke W, Temmerman A, Quirynen M. The accuracy of guided surgery via mucosa-supported stereolithographic surgical templates in the hands of surgeons with little experience. Clin Oral Implants Res 2015;26:1489-94. https://doi.org/10.1111/clr.12494
- Van Assche N, Vercruyssen M, Coucke W, Teughels W, Jacobs R, Quirynen M. Accuracy of computer-aided implant placement. Clin Oral Implants Res 2012;23:112-23. https://doi.org/10.1111/j.1600-0501.2012.02552.x
- Verhamme LM, Meijer GJ, Boumans T, Schutyser F, Berge SJ, Maal TJ. A clinically relevant validation method for implant placement after virtual planning. Clin Oral Implants Res 2013;24:1265-72.
- Lee JH, Park JM, Kim SM, Kim MJ, Lee JH, Kim MJ. An assessment of template-guided implant surgery in terms of accuracy and related factors. J Adv Prosthodont 2013;5:440-7. https://doi.org/10.4047/jap.2013.5.4.440
- Koyanagi K. Development and clinical application of a surgical guide for optimal implant placement. J Prosthet Dent 2002;88:548-52. https://doi.org/10.1067/mpr.2002.129377
- De Kok IJ, Thalji G, Bryington M, Cooper LF. Radiographic stents: integrating treatment planning and implant placement. Dent Clin North Am 2014;58:181-92. https://doi.org/10.1016/j.cden.2013.09.008
- Greenstein G, Greenstein B, Desai RN. Using drill stops on twist drills to promote safety and efficiency when creating osteotomies for dental implants. J Am Dent Assoc 2014;145:371-5. https://doi.org/10.14219/jada.2014.10
- Schwarz L, Pommer B, Bijak M, Watzek G, Unger E. Auto-stop drilling device for implant site preparation: in vitro test of eccentric sensor position. Int J Oral Maxillofac Implants 2015;30:1041-6. https://doi.org/10.11607/jomi.3953
- Juodzbalys G, Wang HL, Sabalys G, Sidlauskas A, Galindo-Moreno P. Inferior alveolar nerve injury associated with implant surgery. Clin Oral Implants Res 2013;24:183-90. https://doi.org/10.1111/j.1600-0501.2011.02314.x
- Nelogi S, Rao BS, Naveen HC, Porwal A, Nelogi M. A surgical guide for optimal placement and immediate restoration of implant. J Oral Implantol 2014;40:623-6. https://doi.org/10.1563/AAID-JOI-D-12-00005
피인용 문헌
- Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol vol.2017, pp.1687-8736, 2017, https://doi.org/10.1155/2017/4292081
- Unilateral Spinous Process Noncovering Hook Type Patient-specific Drill Template for Thoracic Pedicle Screw Fixation vol.42, pp.18, 2017, https://doi.org/10.1097/BRS.0000000000002067
- The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis vol.29, pp.09057161, 2018, https://doi.org/10.1111/clr.13346
- Flapless dental implant surgery and use of cone beam computer tomography guided surgery vol.224, pp.8, 2018, https://doi.org/10.1038/sj.bdj.2018.268
- CAD/CAM implant surgical guides: maximum errors in implant positioning attributable to the properties of the metal sleeve/osteotomy drill combination vol.4, pp.None, 2016, https://doi.org/10.1186/s40729-018-0146-2
- 임플란트 수술용 가이드를 사용한 부분 유도 임플란트 수술의 정확도 평가: 증례보고 vol.57, pp.2, 2016, https://doi.org/10.4047/jkap.2019.57.2.150
- Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery vol.57, pp.3, 2016, https://doi.org/10.4047/jkap.2019.57.3.219
- Impact of Matching Point Selections on Image Registration Accuracy between Optical Scan and Computed Tomography vol.2020, pp.None, 2016, https://doi.org/10.1155/2020/3285431
- Accuracy of the Point-Based Image Registration Method in Integrating Radiographic and Optical Scan Images: A Pilot Study vol.13, pp.1, 2020, https://doi.org/10.5856/jkds.2020.13.1.28
- Does a fully digital workflow improve the accuracy of computer‐assisted implant surgery in partially edentulous patients? A systematic review of clinical trials vol.22, pp.6, 2016, https://doi.org/10.1111/cid.12937
- Accuracy, Labor-Time and Patient-Reported Outcomes with Partially versus Fully Digital Workflow for Flapless Guided Dental Implants Insertion-A Randomized Clinical Trial with One-Year Follow-Up vol.10, pp.5, 2016, https://doi.org/10.3390/jcm10051102
- Clinical and radiographic evaluation of implants placed with fully guided versus partially guided tissue-supported surgical guides: A split-mouth clinical study vol.126, pp.1, 2016, https://doi.org/10.1016/j.prosdent.2020.05.009
- 술자의 영상정합의 경험이 컴퓨터 단층촬영과 광학스캔 영상 간의 정합 정확성과 작업시간에 미치는 영향 vol.59, pp.3, 2016, https://doi.org/10.4047/jkap.2021.59.3.299
- Comparison of the accuracy of implant placement using different drilling systems for static COMPUTER‐ASSISTED implant surgery: A simulation‐based experimental study vol.23, pp.4, 2016, https://doi.org/10.1111/cid.13032