Abstract

In this study, we investigated the operating method of a driver for an air conditioning system according to the temperature difference between the indoor and outdoor environments of a car parked outside during the summer. Researchers of this study suggest the comfort mode of a car air conditioner to improve the thermal comfort of the driver, thereby maintaining longer comfort. This study separately, analyzed temperatures on a cloudy day and sunny day. The results showed the car indoor heat environment and physiological results (EEG, ECG) of the subject. It showed a difference of the car indoor heat environment by weather with the difference also appearing in the physiological response of the subject. In conclusion, in this paper, on the basis of the physiological response of a subject, a comfortable algorithm of automobile air conditioner is being suggested.

Keywords

References

  1. Ministry of Land, Infrastructure and Transport, Korea.
  2. Seo, J. W., 2013, Numerical study on the assessment of inoor environmental quality in automotive cabin. Ph.D Thesis, Ajou University.
  3. Seo, D. C. and Oh, P. K., 2003, A automobile air conditioning system computer simulation which uses CFD, Proceeding of SAREK, pp. 143-146.
  4. Seo, J. W., Park, J. H., and Choi, Y. H., 2012, Evaluation of thermal comfort and cooldown performance inside automotive cabin according to air-conditioning vent location, Int. Transactions of KSAE, Vol. 20, No. 5, pp. 120-129.
  5. Kim, B. S., Min, B. C., Kim, J. H., and Min, Y. K., 2011, Driving performance and Heart-rate change of middle-aged drivers in left-turn situation, Int. Journal of the Ergonomics Society of Korea, Vol. 30, No. 1, pp. 213-220. https://doi.org/10.5143/JESK.2011.30.1.213
  6. Kim, Y. K., Yang, J. S., Baek, J. H., Kim, K. C., and Ji, H. S., 2010, Numerical analysis on the initial cooldown performance inside an automobile for the evaluation of passenger's thermal comfort, Int. Transactions of KSAE, Vol. 18, No. 5, pp. 115-123.
  7. Hardy, J. D. and Dubois, E. F., 1938, The technique of measuring radiation and convection, Journal of Nutrition, Vol. 15, No. 5, pp. 461-475. https://doi.org/10.1093/jn/15.5.461
  8. Kim, M. S., Kim, D. G., Lee, G. D., and Kum, J. S., 2014, Comfort control algorithm development of car air conditioner using thermal comfort evaluation of driver: Part I-Air-conditioning operating preference of driver, Int. Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 26, No. 6, pp. 294-300. https://doi.org/10.6110/KJACR.2014.26.6.294