DOI QR코드

DOI QR Code

Volumetric modulated arc therapy for carotid sparing in the management of early glottic cancer

  • Kim, Young Suk (Department of Radiation Oncology, Jeju National University Hospital, Jeju National University School of Medicine) ;
  • Lee, Jaegi (Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University) ;
  • Park, Jong In (Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University) ;
  • Sung, Wonmo (Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University) ;
  • Lee, Sol Min (Department of Radiation Oncology, Jeju National University Hospital, Jeju National University School of Medicine) ;
  • Kim, Gwi Eon (Department of Radiation Oncology, Jeju National University Hospital, Jeju National University School of Medicine)
  • 투고 : 2015.09.10
  • 심사 : 2015.11.17
  • 발행 : 2016.03.31

초록

Purpose: Radiotherapy of the neck is known to cause carotid artery stenosis. We compared the carotid artery dose received between volumetric modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (IMRT) plans in patients with early glottic cancer. Materials and Methods: Twenty-one early glottic cancer patients who previously underwent definitive radiotherapy were selected for this study. For each patient, double arc VMAT, 8-field IMRT, 3-dimensional conformal radiotherapy (3DCRT), and lateral parallel-opposed photon field radiotherapy (LPRT) plans were created. The 3DCRT plan was generated using lateral parallel-opposed photon fields plus an anterior photon field. VMAT and IMRT treatment plan optimization was performed under standardized conditions to obtain adequate target volume coverage and spare the carotid artery. Dose-volume specifications for the VMAT, IMRT, 3DCRT, and LPRT plans were calculated with radiotherapy planning system. Monitor units (MUs) and delivery time were measured to evaluate treatment efficiency. Results: Target volume coverage and homogeneity results were comparable between VMAT and IMRT; however, VMAT was superior to IMRT for carotid artery dose sparing. The mean dose to the carotid arteries in double arc VMAT was reduced by 6.8% compared to fixed-field IMRT (p < 0.001). The MUs for VMAT and IMRT were not significantly different (p = 0.089). VMAT allowed an approximately two-fold reduction in treatment delivery time in comparison to IMRT (3 to 5 minutes vs. 5 to 10 minutes). Conclusion: VMAT resulted in a lower carotid artery dose compared to conventional fixed-field IMRT, and maintained good target coverage in patients with early glottic cancer.

키워드

참고문헌

  1. Mendenhall WM, Werning JW, Hinerman RW, Amdur RJ, Villaret DB. Management of T1-T2 glottic carcinomas. Cancer 2004;100:1786-92. https://doi.org/10.1002/cncr.20181
  2. Riegel AC, Antone J, Schwartz DL. Comparative dosimetry of volumetric modulated arc therapy and limited-angle static intensity-modulated radiation therapy for early-stage larynx cancer. Med Dosim 2013;38:66-9. https://doi.org/10.1016/j.meddos.2012.07.002
  3. Janssen S, Glanzmann C, Huber G, Studer G. Risk-adapted partial larynx and/or carotid artery sparing modulated radiation therapy of glottic cancer. Radiat Oncol 2014;9:136. https://doi.org/10.1186/1748-717X-9-136
  4. Cheng SW, Ting AC, Wu LL. Ultrasonic analysis of plaque characteristics and intimal-medial thickness in radiationinduced atherosclerotic carotid arteries. Eur J Vasc Endovasc Surg 2002;24:499-504. https://doi.org/10.1053/ejvs.2002.1752
  5. Kim JH, Jenrow KA, Brown SL. Mechanisms of radiationinduced normal tissue toxicity and implications for future clinical trials. Radiat Oncol J 2014;32:103-15. https://doi.org/10.3857/roj.2014.32.3.103
  6. Martin JD, Buckley AR, Graeb D, Walman B, Salvian A, Hay JH. Carotid artery stenosis in asymptomatic patients who have received unilateral head-and-neck irradiation. Int J Radiat Oncol Biol Phys 2005;63:1197-205. https://doi.org/10.1016/j.ijrobp.2005.04.017
  7. Wilbers J, Dorresteijn LD, Haast R, et al. Progression of carotid intima media thickness after radiotherapy: a long-term prospective cohort study. Radiother Oncol 2014;113:359-63. https://doi.org/10.1016/j.radonc.2014.10.012
  8. Kim ES, Yeo SG. Volumetric modulated arc radiotherapy sparing the thyroid gland for early-stage glottic cancer: a dosimetrical analysis. Oncol Lett 2014;7:1987-91. https://doi.org/10.3892/ol.2014.2039
  9. Matthiesen C, Herman Tde L, Singh H, et al. Dosimetric and radiobiologic comparison of 3D conformal, IMRT, VMAT and proton therapy for the treatment of early-stage glottic cancer. J Med Imaging Radiat Oncol 2015;59:221-8. https://doi.org/10.1111/1754-9485.12227
  10. Chera BS, Amdur RJ, Morris CG, Mendenhall WM. Carotidsparing intensity-modulated radiotherapy for early-stage squamous cell carcinoma of the true vocal cord. Int J Radiat Oncol Biol Phys 2010;77:1380-5. https://doi.org/10.1016/j.ijrobp.2009.07.1687
  11. Camingue P, Christian R, Ng D, Williams P, Amin M, Roniger DL. Comparison of external beam treatment techniques for T1-2, N0, M0 glottic cancers. Med Dosim 2012;37:221-4. https://doi.org/10.1016/j.meddos.2011.08.002
  12. Atalar B, Gungor G, Caglar H, Aydin G, Yapici B, Ozyar E. Use of volumetric modulated arc radiotherapy in patients with early stage glottic cancer. Tumori 2012;98:331-6. https://doi.org/10.1177/030089161209800309
  13. Gomez D, Cahlon O, Mechalakos J, Lee N. An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer. Radiat Oncol 2010;5:74. https://doi.org/10.1186/1748-717X-5-74
  14. Osman SO, Astreinidou E, de Boer HC, et al. IMRT for imageguided single vocal cord irradiation. Int J Radiat Oncol Biol Phys 2012;82:989-97. https://doi.org/10.1016/j.ijrobp.2010.12.022
  15. Osman SO, Astreinidou E, Levendag PC, Heijmen BJ. Impact of geometric variations on delivered dose in highly focused single vocal cord IMRT. Acta Oncol 2014;53:278-85. https://doi.org/10.3109/0284186X.2013.812793
  16. Kim TH, Kim MS, Choi SH, et al. Postoperative radiotherapy in salivary ductal carcinoma: a single institution experience. Radiat Oncol J 2014;32:125-31. https://doi.org/10.3857/roj.2014.32.3.125
  17. Ang KK, Garden AS. Radiotherapy for head and neck cancers: indications and techniques. 3rd ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2006.
  18. Zhang P, Happersett L, Hunt M, Jackson A, Zelefsky M, Mageras G. Volumetric modulated arc therapy: planning and evaluation for prostate cancer cases. Int J Radiat Oncol Biol Phys 2010;76:1456-62. https://doi.org/10.1016/j.ijrobp.2009.03.033
  19. White P, Chan KC, Cheng KW, Chan KY, Chau MC. Volumetric intensity-modulated arc therapy vs conventional intensitymodulated radiation therapy in nasopharyngeal carcinoma: a dosimetric study. J Radiat Res 2013;54:532-45. https://doi.org/10.1093/jrr/rrs111
  20. Scorsetti M, Bignardi M, Clivio A, et al. Volumetric modulation arc radiotherapy compared with static gantry intensitymodulated radiotherapy for malignant pleural mesothelioma tumor: a feasibility study. Int J Radiat Oncol Biol Phys 2010;77:942-9. https://doi.org/10.1016/j.ijrobp.2009.09.053
  21. Rosenthal DI, Fuller CD, Barker JL Jr, et al. Simple carotidsparing intensity-modulated radiotherapy technique and preliminary experience for T1-2 glottic cancer. Int J Radiat Oncol Biol Phys 2010;77:455-61. https://doi.org/10.1016/j.ijrobp.2009.04.061
  22. Clivio A, Fogliata A, Franzetti-Pellanda A, et al. Volumetricmodulated arc radiotherapy for carcinomas of the anal canal: a treatment planning comparison with fixed field IMRT. Radiother Oncol 2009;92:118-24. https://doi.org/10.1016/j.radonc.2008.12.020
  23. Abayomi OK. Neck irradiation, carotid injury and its consequences. Oral Oncol 2004;40:872-8. https://doi.org/10.1016/j.oraloncology.2003.12.005
  24. Ackerman LV. The pathology of radiation effect of normal and neoplastic tissue. Am J Roentgenol Radium Ther Nucl Med 1972;114:447-59.
  25. Hopewell JW, Campling D, Calvo W, Reinhold HS, Wilkinson JH, Yeung TK. Vascular irradiation damage: its cellular basis and likely consequences. Br J Cancer Suppl 1986;7:181-91.
  26. Rotman M, Seidenberg B, Rubin I, Botstein C, Bosniak M. Aortic arch syndrome secondary to radiation in childhood. Arch Intern Med 1969;124:87-90. https://doi.org/10.1001/archinte.1969.00300170089017
  27. Vanetti E, Clivio A, Nicolini G, et al. Volumetric modulated arc radiotherapy for carcinomas of the oro-pharynx, hypopharynx and larynx: a treatment planning comparison with fixed field IMRT. Radiother Oncol 2009;92:111-7. https://doi.org/10.1016/j.radonc.2008.12.008
  28. Verbakel WF, Cuijpers JP, Hoffmans D, Bieker M, Slotman BJ, Senan S. Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study. Int J Radiat Oncol Biol Phys 2009;74:252-9. https://doi.org/10.1016/j.ijrobp.2008.12.033

피인용 문헌

  1. Defining the Optimal Time of Adaptive Replanning in Prostate Cancer Patients with Weight Change during Volumetric Arc Radiotherapy: A Dosimetric and Mathematical Analysis Using the Gamma Index vol.2017, pp.None, 2016, https://doi.org/10.1155/2017/4149591
  2. Primary lung sarcoma treated with stereotactic ablative radiotherapy: a case report vol.10, pp.None, 2016, https://doi.org/10.2147/ott.s138595
  3. Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR vol.90, pp.1070, 2017, https://doi.org/10.1259/bjr.20160652
  4. Dosimetric effects of sectional adjustments of collimator angles on volumetric modulated arc therapy for irregularly-shaped targets vol.12, pp.4, 2016, https://doi.org/10.1371/journal.pone.0174924
  5. Dosimetric effects of sectional adjustments of collimator angles on volumetric modulated arc therapy for irregularly-shaped targets vol.12, pp.4, 2016, https://doi.org/10.1371/journal.pone.0174924
  6. Gamma analysis with a gamma criterion of 2%/1 mm for stereotactic ablative radiotherapy delivered with volumetric modulated arc therapy technique: a single institution experience vol.8, pp.44, 2017, https://doi.org/10.18632/oncotarget.18530
  7. Study design and early result of a phase I study of SABR for early-stage glottic cancer : SABR for Early Glottic Cancer vol.128, pp.11, 2018, https://doi.org/10.1002/lary.27226
  8. Optimal collimator rotation based on the outline of multiple brain targets in VMAT vol.13, pp.None, 2016, https://doi.org/10.1186/s13014-018-1039-5
  9. Comparison of Significant Carotid Stenosis for Nasopharyngeal Carcinoma between Intensity-Modulated Radiotherapy and Conventional Two-Dimensional Radiotherapy vol.8, pp.None, 2018, https://doi.org/10.1038/s41598-018-32398-y
  10. Hypofractionated radiotherapy for early glottic cancer: a retrospective interim analysis of a single institution vol.37, pp.2, 2019, https://doi.org/10.3857/roj.2019.00143
  11. Significant Reduction in Vertebral Artery Dose by Intensity Modulated Proton Therapy: A Pilot Study for Nasopharyngeal Carcinoma vol.11, pp.8, 2021, https://doi.org/10.3390/jpm11080822