DOI QR코드

DOI QR Code

Analytical Study for Performance Evaluation of Studs for Steel Plate Concrete (SC) Walls subjected to Forced Vibration

강제진동을 받는 강판 콘크리트 (SC) 벽체에서 스터드의 성능평가를 위한 해석적 연구

  • 이성태 (인하공업전문대학 토목환경과)
  • Received : 2016.01.15
  • Accepted : 2016.02.15
  • Published : 2016.05.01

Abstract

This study analytically reviewed the behavior of steel plate concrete (SC) walls subjected to forced vibration to investigate the effects of shape and arrangement spacing of studs on the behavior spacing of studs in SC wall were carried out. From the analyses, it was noted that the damping ratio obtained from the time history analyses showed overall high value in Half-power Bandwidth method and the lowest value in Fitted Exponential Curve method. And, in half of the design strength, the damping ratio presented approximately 3.0~4.2% and, in the design strength, it was approximately 4.1~5.2%. When the developed studs were used, the damping ratio was reduced slightly and it did not show consistent results between DS1 and DS2. When the distance between the studs increases more than necessary, it was also confirmed that the natural frequency was reduced and the damping ratio was increased.

이 연구에서는 SC 전단벽의 전단 연결재인 스터드의 배치와 형상이 SC 전단벽의 거동에 미치는 영향을 살펴보기 위해 전단벽체가 강제진동을 받을 때의 거동을 해석적으로 검토하였다. 이를 위해 서로 다른 배치간격과 형상의 스터드가 배열된 SC 전단벽을 대상으로 유한요소해석을 수행하였다. 그 결과, 시간이력해석으로부터 구한 감쇠비가 파워반감대역폭법이 전반적으로 높게 그리고 적합지수함수법이 가장 낮은 수준으로 산정했으며 설계강도 절반정도에서의 감쇠비는 3.0~4.2%로, 설계강도에서는 4.1~5.2%로 나타남을 알 수 있었다. 또한, 개선된 스터드를 사용할 때, 감쇠비가 약간 감소하였고 DS1과 DS2 간에는 일관된 결과가 나타나지 않았다. 스터드의 간격이 필요이상 증가할 경우, 고유진동수가 감소하고 감쇠비가 증가함을 확인하였다.

Keywords

References

  1. Akiyama, H., Sekimoto, H., Tanaka, M., Inoue, K., Fukihara, M., and Okuda, (1989), Y., 1/10th Scale Model Test of Inner Concrete Structure Composed of Concrete Filled Steel Bearing Wall", 10th SMiRT, 73-78.
  2. Baltay, P. and Gjelsvik, A. (1990), Coefficient of Friction for Steel on Concrete at High Normal Stress" Journal of Materials in Civil Engineering, 2(1), 46-49. https://doi.org/10.1061/(ASCE)0899-1561(1990)2:1(46)
  3. Carreira, D. J. and Chu, K. H. (1985), Stress-strain Relationship for Plain Concrete in Compression, ACI Journal, American Concrete Institute, 82(6), 797-804.
  4. Cho, S. G., Lim, J. S., Jeong, Y. D., and Yi, S. T. (2014), Analytical Study for Performance Improvement of Studs for Steel Plate Concrete(SC) Walls subjected to Bending Moment, Journal of the Korea Institute for Structural Maintenance and Inspection, KSMI, 18(2), 74-81. (in Korean, with English abstract). https://doi.org/10.11112/jksmi.2014.18.2.074
  5. Cho, S. G., So, G. H., Kim, D. K., and Han, S. M. (2015), Structural Damping Ratio of Steel Plate Concrete(SC) Shear Wall at the Low Stress Level Identified by Vibration Test, Journal of the Korean Society of Civil Engineers, 35(2), 255-264 (in Korean, with English abstract). https://doi.org/10.12652/Ksce.2015.35.2.0255
  6. Chung, C. H., Kim, N. S., Lee, J. W., Moon, I. W., and Kim, T. I. (2013), Numerical Simulation of SC Shear Wall Vibration Test Using Explicit Dynamic Analysis Method, Proceeding of The KSNVE 2013 Annual Conference, 89-90 (in Korean, with English abstract).
  7. Evans, R. H. and Marathe, M. S. (1967), Microcracking and Stress-strain Curves for Concrete in Tension, Materials and Structures, 1(1), 61-64.
  8. Jankowiak, T. and Lodygowski, T. (2005), Identification of Parameters of Concrete Damage Plasticity Constitutive Model, Foundation of Civil and Environmental Engineering, No. 6, Poznan University of Technology, Poland, 53-69.
  9. Korea Concrete Institute(KCI) (2012), The Korean Concrete Structure Design Code, Korea Concrete Institute (in Korean).
  10. Korea Electric Association(KEA), (2010), Nuclear Safety Related Structures : Steel-Plate Concrete Structure, KEPIC-SNG, Korea Electric Association.
  11. Lee, S. J. and Kim, W. K. (2010), Damping Ratios for Seismic Design of SC Structures, Korean Society of Steel Construction, 22(5), 487-496 (in Korean, with English abstract).
  12. Lim, J. S., Jeong, Y. D., and Yi, S. T. (2015), Analytical Study for Performance Evaluation of Studs for Steel Plate Concrete(SC) Walls subjected to Cyclic Loads, Journal of the Korea Institute for Structural Maintenance and Inspection, KSMI, 19(4), 35-42 (in Korean, with English abstract).
  13. Prakash, A., Anandavalli, N., Madheswaran, C. K., Rajasankar, J., and Lakshmanan, N. (2011), Three Dimensional FE Model of Stud Connected Steel-Concrete Composite Girders Subjected to Monotonic Loading, International Journal of Mechanics and Applications, 1(1), 1-11.
  14. US NRC, Damping Values for Seismic Design of Nuclear Power Plants, Regulatory Guide 1.61, 2007.

Cited by

  1. Natural frequency and damping ratio of steel plate–concrete walls with inclined studs under forced oscillation vol.70, pp.14, 2018, https://doi.org/10.1680/jmacr.17.00207