DOI QR코드

DOI QR Code

Inelastic Seismic Response Control of the RC Framed Apartment Building Structures Using Exterior-Installed Kagome Damping System

외부접합형 카고메 감쇠시스템을 사용한 철근콘크리트 라멘조 공동주택 비탄성 지진 응답 제어

  • Received : 2016.01.05
  • Accepted : 2016.04.14
  • Published : 2016.05.01

Abstract

Various passive energy dissipation systems have been proposed and widely applied to real building structures under seismic load due to their high energy-dissipation potential and low cost for installation and maintenance. This paper presents nonlinear dynamic analysis results of the effectiveness of exterior-installed Kagome damping system(EKDS) in passively reducing seismic response. Kagome damping system proposed by previous studies has isotropic and bi-linear hysteretic characteristics and the installation configuration is newly presented in this study. The 15 and 20 story RC framed apartment buildings are used for verifying the effectiveness of the EKDS. The stiffness ratio of the damper supporting column to the original building, the number of the dampers, and the installed stories were considered as design parameters. Numerical results demonstrated that the EKDS were very effective in reducing both the two horizontal directional seismic responses by just using smaller number of exterior-installed damping system when compared to the traditional one-directional inter-story installed damping systems.

이 논문은 지진응답을 감소시키기 위해 외부설치형 카고메 감쇠시스템의 유효성을 비선형 동적 해석 결과를 통해 나타내었다. 이전의 연구에 의해 제안된 카고메 감쇠시스템을 활용하여 본 연구에서는 등방성, 이선형 이력특성 및 설치구성이 새롭게 제안하였다. 또한, 외부접합형 카고메 감쇠시스템의 여러 가지 효과를 15층 및 20층 철근콘크리트 라멘조 아파트를 대상으로 검증하였다. 원구조물에 대한 감쇠장치 지지구조물의 강성비, 감쇠장치의 수량 및 설치 층수는 설계변수로 고려하였다. 수치해석결과, EKDS는 기존의 한 방향 층간에 설치되는 감쇠시스템과 비교할 때 더 작은 수를 적용하여도 두 방향의 지진하중을 감소시키는데 매우 효과적임을 입증되었다.

Keywords

References

  1. AIK (2015), Guidelines for Performance-Based Seismic Design of Residential Buildings, Architectural Institute of Korea.
  2. Applied Technology Council (2005), Improvement of Static Seismic Analysis Procedures, FEMA 440 Report.
  3. ASCE (2010), ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures, Reston: American Society. of Civil Engineers, 179-197.
  4. Federal Emergency Management Agency (2000), Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA 356 Report.
  5. Hur, M. W., Lee, S. H., Chun, Y. S. (2015), Vibration Control Effect of the Framed Building Structures according to the Stiffness Ratio of Exo-type Damping System and Damper Device Yield Ratio, Journal of Korea institute for Structural Maintenance Inspection, 19(5), 38-44. https://doi.org/10.11112/jksmi.2015.19.5.038
  6. Hur, M. W., Lee, S. H., Chun, Y. S., (2015), Vibration Control of the Framed Building Structures Using KGDS System with Isotropic Damping Devices, Journal of Korea institute for Structural Maintenance Inspection, 19(2), 52-59. https://doi.org/10.11112/jksmi.2015.19.2.052
  7. Hwang, J. S., Park, S. C., Kang, K. J. (2013), A Study on the Hysteresis properties and Mathematical Model of Kagome Truss Damper, Architectural Institute of Korea, 29(9), 21-29.
  8. KBC, Korean Building and Commentary (2009), Architectural Institute of Korea, 88-90.
  9. Lee, H. H., Kim, S. I. (2010), Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures, Journal of Korea institute for Structural Maintenance Inspection, 14(3), 123-130.
  10. Lee, H. H., Kim, S. I. (2012), Hysteretic Behaviors of Metallic Dampers with the Various Slit Shape, Journal of Korea institute for Structural Maintenance Inspection, 16(2), 206-207.
  11. Oh, S. H., (2012), Optimal vibration control Design Methodology of Apartments, LH technology seminar.
  12. Oh, S. H., Kim, Y. J., Ryu, H, S., Choi, H. B., Kang, C. H. (2005), Hystersis Behavior of Beam-to-Column Connections with Elasto-Plastic Hysteretic Dampers, Architectural Institute of Korea, 25(1), 635-638.