Development of Handpiece Moving System (HMS) for Cutting Performance Evaluation of Dental Ultrasonic Surgery Unit

치과용 초음파 수술기의 절삭성능 평가를 위한 핸드피스 이송 시스템 구축

  • Sa, Min-Woo (Department of Mechanical Engineering, Andong National University) ;
  • Shim, Hae-Ri (Department of Mechanical Engineering, Andong National University) ;
  • Ko, Tae-Jo (Department of Mechanical Engineering, Yeungnam University) ;
  • Lee, Jong-Min (R&D Center, Micro-NX, Co., Ltd.) ;
  • Kim, Jong Young (Department of Mechanical Engineering, Andong National University)
  • Received : 2015.09.30
  • Accepted : 2016.03.21
  • Published : 2016.05.01

Abstract

Recently, research on bone fracture and osteoplasty using ultrasonic bone surgery unit has been ongoing in the fields of dentistry, plastic surgery, and otorhinolaryngology. However, detailed data evaluation with ultrasonic bone surgery unit has not been conducted to date. In this study, we developed handpiece moving system (HMS) for cutting performance evaluation. In the experimental setup of HMS, a handpiece was immobilized, and bone samples from cortical bone of bovine leg were prepared. Also, the experimental process was described in detail, and a basic experiment was carried out to evaluate the cutting performance. Future study is required on all experimental process conditions by HMS.

Keywords

References

  1. Ministry of Food and Drug Safety, "2014 International Medical Device Product Results," http://www.mfds.go.kr/index.do (Accessed 22 April 2016)
  2. Dmetec, "Introduction to Dental Medical Technology," http://www.dmetec.com/ (Accessed 22 April 2016)
  3. Vercellotti, T., "Technological Characteristics and Clinical Indications of Piezoelectric Bone Surgery," Minerva Stomatologica, Vol. 53, No. 5, pp. 207-214, 2004.
  4. Lee, J.-H., Oh, J.-M., Hong, Y., Kim, S., Paik, J., et al., "Design and Evaluation of Ultrasonic Bone Surgical Instruments for Dental Application," Journal of the Korean Institute of Electrical and Electronic Material Engineers, Vol. 25, No. 12, pp. 990-995, 2012. https://doi.org/10.4313/JKEM.2012.25.12.990
  5. Harder, S., Wolfart, S., Mehl, C., and Kern, M., "Performance of Ultrasonic Devices for Bone Surgery and Associated Intraosseous Temperature Development," International Journal of Oral & Maxillofacial Implants, Vol. 24, No. 3, pp. 484-490, 2009.
  6. Khambay, B. and Walmsley, A., "Investigations into the Use of an Ultrasonic Chisel to Cut Bone. Part 2: Cutting Ability," Journal of Dentistry, Vol. 28, No. 1, pp. 39-44, 2000. https://doi.org/10.1016/S0300-5712(99)00044-5
  7. Hong, J. W., "Effect of Wear on Tooth Surface and Efficiency of New Ultrasonic Scaler Tip," M.Sc. Thesis, School of Dentistry, Seoul National University, 2013.
  8. Cottle, E., Kulild, J. C., and Walker, M. P., "A Comparison of Dentin Cutting Efficiency of 4 Round-Tipped Ultrasonic Instruments," Journal of Endodontics, Vol. 39, No. 8, pp. 1051-1053, 2013. https://doi.org/10.1016/j.joen.2013.03.005
  9. Baek, S. H., Shon, W. J., Bae, K. S., Kum, K. Y., Lee, W. C., et al., "Evaluation of the Safety and Efficiency of Novel Metallic Ultrasonic Scaler Tip on Titanium Surfaces," Clinical Oral Implants Research, Vol. 23, No. 11, pp. 1269-1274, 2012. https://doi.org/10.1111/j.1600-0501.2011.02302.x
  10. Cardoni, A., MacBeath, A., and Lucas, M., "Methods for Reducing Cutting Temperature in Ultrasonic Cutting of Bone," Ultrasonics, Vol. 44, pp. e37-e42, 2006. https://doi.org/10.1016/j.ultras.2006.06.046