DOI QR코드

DOI QR Code

Influence of special plaster on the out-of-plane behavior of masonry walls

  • Donduren, Mahmut Sami (Department of Civil Engineering, Faculty of Engineering, Selcuk University) ;
  • Kanit, Recep (Department of Civil Engineering, Faculty of Technology, Gazi University) ;
  • Kalkan, Ilker (Department of Civil Engineering, Faculty of Engineering, Kirikkale University) ;
  • Gencel, Osman (Department of Civil Engineering, Faculty of Engineering, Bartin University)
  • Received : 2014.12.24
  • Accepted : 2015.12.16
  • Published : 2016.04.25

Abstract

The present study aimed at investigating the effect of a special plaster on the out-of-plane behavior of masonry walls. A reference specimen, plastered with conventional plaster, and a specimen plastered with a special plastered were tested under reversed cyclic lateral loading. The specimens were identical in dimensions and material properties. The special plaster contained an additive, which increased the adherence strength of the plaster to the wall. The amount of the additive in the mortar was adjusted based on the preliminary material tests. The influence of the plaster on the wall behavior was evaluated according to the initial cracking load, type of failure, energy absorption capacity (modulus of toughness), and crack pattern of the wall. Despite having limited contribution to the ductility, the special plaster increased the ultimate load capacity of the wall about 25%. The failure mode of the wall with special plaster resembled the plastic failure mechanism of a reinforced concrete slab in the formation of yielding lines along the wall. The deflection at failure and the modulus of toughness of the wall with special plaster were measured to be in order of 60% and 75% of the corresponding values of the reference wall.

Keywords

Acknowledgement

Supported by : Selcuk University

References

  1. ASTM E519/E519M-10 (2010), Standard Test Method for Diagonal Tension (shear) in Masonry Assemblages, American Society for Testing and Materials, West Conshocken, Pennsylvania, USA.
  2. Augenti, N., Parisi, F., Prota, A. and Manfredi, G. (2011), "In-plane lateral response of a full-scale masonry subassemblage with and without an inorganic matrix-grid strengthening system", J. Compos. Constr., 15(4), 578-590. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000193
  3. Babaeidarabad, S., Caso, F. and Nanni, A. (2014), "Out-of-plane behavior of URM walls strengthened with fabric-reinforced cementitious matrix composite", J. Compos. Constr., 18(4), doi: 10.1061/(ASCE)CC.1943-5614.0000457.
  4. Babaeidarabad, S. and Nanni, A. (2015), "Out-of-plane strengthening of URM walls with Fabric-Reinforced-Cementitious-Matrix (FRCM)", ACI Spec. Pub., 299, 1-12.
  5. Basaran, H., Demira, A., Bagci, M. and Ergun, S. (2015), "Experimental and numerical investigation of walls strengthened with fiber plaster", Struct. Eng. Mech., 56(2), 189-200. https://doi.org/10.12989/sem.2015.56.2.189
  6. BS EN 772-1:2000 (2000), Methods of Test for Masonry Units. Determination of compressive strength, British Standards Institute, London, UK.
  7. De Felice, G., De Santis, S., Garmendia, L., Ghiassi, B., Larrinaga, P., Lourenco, P.B., Oliveira, D.V., Paolacci, F. and Papanicolaou, C.G. (2014), "Mortar-based systems for externally bonded strengthening of masonry", Mater. Struct., 47(12), 2021-2037. https://doi.org/10.1617/s11527-014-0360-1
  8. Dizhur, D., Derakhshan, H., Lumantarna, R., Griffth, M. and Ingham, J. (2010a), "Out-of-plane strengthening of unreinforced masonry walls using near surface mounted fibre reinforced polymer strips", J. Struct. Eng. Soc. NZ. Inc., 23(2), 91-103.
  9. Dizhur, D., Derakhshan, H., Lumantarna, R. and Ingham, J.M. (2010b), "In-situ out-of-plane testing of unreinforced masonry wall segment in Wintec Block F building", 2010 New Zealand Society for Earthquake Engineering Technical Conference, Wellington, New Zealand.
  10. Dizhur, D., Lumantarna, R., Derakhshan, H. and Ingham, J.M. (2010c), "In-situ testing of a residential unreinforced masonry building in Wellington, New Zealand", 8th International Masonry Conference, Dresden, Germany.
  11. Durham, A.S. (2002), "Influence of confinement plates on the seismic performance of reinforced clay brick masonry walls", M.Sc. Thesis, North Carolina State University, Raleigh, North Carolina, USA.
  12. Ehsani, M., Saadatmanesh, H. and Velazquez-Dimas, J. (1999), "Behavior of retrofitted URM walls under simulated earthquake loading", J. Compos. Constr., 3(3), 134-142. https://doi.org/10.1061/(ASCE)1090-0268(1999)3:3(134)
  13. Erdal, M. (2010), "Improving out-of-plane strength and ductility of unreinforced masonry walls in low-rise buildings by centrally applied FRP strip", Int. J. Phys. Sci., 5(2), 116-131.
  14. Ghobarah, A. and El Mandooh Galal K. (2004), "Out-of-plane strengthening of unreinforced masonry walls with openings", J. Compos. Constr., 8(4), 298-305. https://doi.org/10.1061/(ASCE)1090-0268(2004)8:4(298)
  15. Haddad, M.A., Shaheen, E., Parsekian, G.A., Tilleman, D. and Shrive, N.G. (2010), "Strengthening of a concrete masonry wall subject to lateral load with sprayed glass-fibre-reinforced polymer", Can J. Civ. Eng., 37(10), 1315-1330. https://doi.org/10.1139/L10-074
  16. Hamilton III H.R. and Dolan, C. (2001), "Flexural capacity of glass FRP strengthened concrete masonry walls", J. Compos. Constr., 5(3), 170-178. https://doi.org/10.1061/(ASCE)1090-0268(2001)5:3(170)
  17. Hamoush, S.A., McGinley, M.W., Mlakar, P., Scott, D. and Kenneth, M. (2001), "Out-of-plane strengthening of masonry walls with reinforced composites", J. Compos. Constr., 5(3), 139-145. https://doi.org/10.1061/(ASCE)1090-0268(2001)5:3(139)
  18. Ismail, N., Laursen, P.T., Schultz, A.E. and Ingham, J. M. (2011), "Cyclic out-of-plane behaviour of posttensioned clay brick masonry", The Eleventh North American Masonry Conference, Minneapolis, Minnesota, USA.
  19. Kanit, R. and Atimtay, E. (2006), "Experimental assessment of the seismic behavior of load-bearing masonry walls loaded out-of-plane", Turkish J. Eng. Envir. Sci., 30(2), 101-113.
  20. Papanicolaou, C., Triantafillou, T. and Lekka, M. (2011), "Externally bonded grids as strengthening and seismic retrofitting materials of masonry panels", Constr. Build. Mater., 25(2), 504-514. https://doi.org/10.1016/j.conbuildmat.2010.07.018
  21. Prota, A., Marcari, G., Fabbrocino, G., Manfredi, G. and Aldea, C. (2006), "Experimental in-plane behavior of tuff masonry strengthened with cementitious matrix-grid composites", J. Compos. Constr., 10(3), 91-103. https://doi.org/10.1061/(ASCE)1090-0268(2006)10:2(91)
  22. TEC-2007 Turkish Earthquake Code (2007), Regulations on Structures Constructed in Disaster Regions, Ministry of Public Works and Settlement, Ankara, Turkey.
  23. Turkish Standard TS 498 (1997), Design Loads for Buildings, Turkish Standards Institutions, Ankara, Turkey.