DOI QR코드

DOI QR Code

Electromagnetic Pulse (EMP) Shielding Effectiveness of Waveguide-Below-Cutoff (WBC) Arrays Installed in Generator Exhaust Chimney and its Effects on Gas Velocity

도파관 배열이 설치된 비상발전기 연도의 유속 예측 및 EMP 차폐평가

  • Pang, Seung-Ki (Department of Architecture, KyungMin College) ;
  • Kim, Jae-Hun (Department of Architecture, KyungMin College) ;
  • Yook, Jong-Gwan (Department of Electrical and Electronic Engineering, Yonsei University) ;
  • Kim, Yuna (Department of Electrical and Electronic Engineering, Yonsei University) ;
  • Kim, Sangin (Department of Electrical and Electronic Engineering, Yonsei University) ;
  • Kim, Suk-Bong (Department of Civil Engineering & Environmental Science, Korea Military Academy)
  • Received : 2015.12.16
  • Accepted : 2016.02.03
  • Published : 2016.03.01

Abstract

Characteristics of exhaust from chimney of electricity generator are analyzed based on CFD when Waveguide-Below-Cutoff (WBC) array is installed in order to achieve the certain level of electromagnetic pulse (EMP) shielding. The main purpose is prediction of average and maximum velocity of exhaust. The results reveal that: 1) When the specification of waveguide is given as 80-diameter, 400-length, and the gap of 20 mm, the shielding effectiveness (SE) is 140dB. The average and maximum velocity of exhaust in the chimney with WBC Array can be represented as exponential functions. 2) As the number of WBC increases, the velocity in the chimney dwindles. 3) Under the situation that WBC with 80 mm diameter is located at intervals of 20 mm, the average velocity can be approximated by $25.5344{\times}e^{(-0.0098{\times}N_{WBC})}$ with input velocity of 15 m/s. In addition, the determination coefficient is 0.915, which is sufficiently high.

Keywords

References

  1. S. K. Pang, Y. T. Chae, J. G. Yook, Yuna Kim, Sangin Kim, 2015, Air Stream around EMP Protective Device for Emergency Power System, Proceedings of the Geothermal Energy Engineers, Vol. 1, Korea Society of Geothermal Energy Engineers, Daejeon, Korea, pp. 41-44.
  2. Military Standard Sheet, 2005, High-Altitude Electromagnetic Pulse (HEMP) Protection for Ground-based C41 Facilities Performing Critical, Time-urgent missions Part 1 Fixed Facilities.
  3. W. A. Bereuter and D. Chang, 1982, Shielding effectiveness of metallic honeycombs, IEEE Transactions on Electromagnetic Compatibility, Vol. EMC-24, no. 1.

Cited by

  1. 수정된 차폐효과 방정식을 이용한 다층 구조 도파관의 EMP 차폐 분석 vol.28, pp.6, 2016, https://doi.org/10.5515/kjkiees.2017.28.6.452