Acknowledgement
Supported by : National Natural Science Foundation of China
References
- An, X.H., Shawky, A.A. and Maekawa, K. (1997), "The collapse mechanism of a subway station during the Great Hanshin Earthquake", Cement Concrete Compos., 19(3), 241-257. https://doi.org/10.1016/S0958-9465(97)00014-0
- Asher, J.W., Hoskere, S.N., Ewing, R.D., Mayes, R.L., Button, M.R. and Van Volkinburg, D.R. (1997), "Performance of seismically isolated structures in the 1994 Northridge and 1995 Kobe earthquakes", Proceedings of Structures Congress XV, Portland, USA, April.
- Bhuiyan, A.R., Razzaq, M.K., Okui, Y., Mitamura, H. and Imai, T. (2009), "A simplified rheology model of natural and lead rubber bearings for seismic analysis", Proceedings of the 64th JSCE Annual Conference, Fukuoka, Japan, September.
- Cao, B.Z., Luo, Q.F., Ma, S. and Liu, J.B. (2002), "Seismic response analysis of Daikai subway station in Hyogoken-Nanbu earthquake", Earthq. Eng. Eng. Vib., 22(4), 102-107. (in Chinese)
- Chopra, A.K. (2007), Dynamics of Structures: Theory and Applications to Earthquake Engineering, 3rd Edition, Pearson Prentice Hall, New Jersey, USA.
- Das, B.M. (2008), Advanced Soil Mechanics, CRC Press, Florida, USA.
- Hashash, Y.M.A., Hook, J.J., Schmidt, B. and Yao, J.I.C (2001), "Seismic design and analysis of underground structures", Tunnel. Underg. Space Tech., 16(4), 247-293. https://doi.org/10.1016/S0886-7798(01)00051-7
- Hu, J.W. (2015), "Response of seismically isolated steel frame buildings with sustainable lead-rubber bearing (LRB) isolator devices subjected to near-fault (NF) ground motions", Sustainab., 7(1), 111-137.
- Huo, H., Bobet, A., Fernandez, G. and Ramirez, J. (2005), "Load transfer mechanisms between underground structure and surrounding ground: evaluation of the failure of the Daikai Station", J. Geotech. Geoenviron. Eng., 131(12), 1522-1533. https://doi.org/10.1061/(ASCE)1090-0241(2005)131:12(1522)
- Hwang, J.S. and Chiou, J.M. (1996), "An equivalent linear model of lead-rubber seismic isolation bearings", Eng. Struct., 18(7), 528-536. https://doi.org/10.1016/0141-0296(95)00132-8
- Iida, H., Hiroto, T., Yoshida, N. and Iwafuji, M. (1996), "Damage to Daikai subway station", Soil. Found., Special Issue, 283-300.
- Islam, A.B.M.S., Hussain, R.R., Jumaat, M.Z. and Rahman, M.A. (2013), "Nonlinear dynamically automated excursions for rubber-steel bearing isolation in multi-storey construction", Auto. Constr., 30, 265-275. https://doi.org/10.1016/j.autcon.2012.11.010
- Jangid, R.S. (2007), "Optimum lead-rubber isolation bearings for near-fault motions", Eng. Struct., 29(10), 2503-2513. https://doi.org/10.1016/j.engstruct.2006.12.010
- Jangid, R.S. (2010), "Stochastic response of building frames isolated by lead-rubber bearings", Struct. Control Health Monit., 17(1), 1-22. https://doi.org/10.1002/stc.266
- JGS-4001-2004 (2006), Principles for Foundation Designs Grounded on a Performance-based Design Concept, Japan.
- Kelly, T.E., Robinson, W.H. and Skinner, R.I. (2006), Seismic Isolation for Designers and Structural Engineers, Robinson Seismic Ltd, Wellington, New Zealand.
- Li, Y., Li, Z.L. and Xu, J. (2013), "Study on optimization of bearing parameters for large-scale LRB-based isolated storage tank", World Earthq. Eng., 29(1), 131-138. (in Chinese)
- Matsagar, V.A. and Jangid, R.S. (2004), "Influence of isolator characteristics on the response of base-isolated structures", Eng. Struct., 26(12), 1735-1749. https://doi.org/10.1016/j.engstruct.2004.06.011
- Mkrtychev, O.V., Dzhinchvelashvili, G.A. and Bunov, A.A. (2014), "Study of lead rubber bearings operation with varying height buildings at earthquake", Procedia Eng., 91, 48-53. https://doi.org/10.1016/j.proeng.2014.12.010
- Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures: from Theory to Practice, John Wiley and Sons, New York, NY, USA.
- Nagarajaiah, S. and Sun, X.H. (2000), "Response of base-isolated USC hospital building in Northridge earthquake", J. Struct. Eng., 126(10), 1177-1186. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:10(1177)
- Park, J.G. and Otsuka, H. (1999), "Optimal yield level of bilinear seismic isolation devices", Earthq. Eng. Struct. Dyn., 28(9), 941-955. https://doi.org/10.1002/(SICI)1096-9845(199909)28:9<941::AID-EQE848>3.0.CO;2-5
- Parra-Montesinos, G.J., Bobet, A. and Ramirez, J.A. (2006), "Evaluation of soil-structure interaction and structural collapse in Daikai subway station during Kobe earthquake", ACI Struct. J., 103(1), 113-122.
- Providakis, C.P. (2008), "Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations", Eng. Struct., 30(5), 1187-1198. https://doi.org/10.1016/j.engstruct.2007.07.020
- Ryan, K.L., Kelly, J.M. and Chopra, A.K. (2005), "Nonlinear model for lead-rubber bearings including axial-load effects", J. Eng. Mech., 131(12), 1270-1278. https://doi.org/10.1061/(ASCE)0733-9399(2005)131:12(1270)
- Soong, T.T. and Spencer, B.F. (2002), "Supplemental energy dissipation: state-of-the-art and state-of-thepractice", Eng. Struct., 24(3), 243-259. https://doi.org/10.1016/S0141-0296(01)00092-X
- Yamato, T., Umehara, T., Aoki, H., Nakamura, S., Ezaki, J. and Suetomi, I. (1996), "Damage to Daikai subway station of Kobe rapid transit system and estimation of its reason during the 1995 Hyogoken-Nanbu earthquake", Proceedings of JSCE, 537, 303-320. (in Japanese)
- Zordan, T., Liu, T., Briseghella, B. and Zhang, Q.L. (2014), "Improved equivalent viscous damping model for base-isolated structures with lead rubber bearing", Eng. Struct., 75, 340-352. https://doi.org/10.1016/j.engstruct.2014.05.044
Cited by
- Design approach of high damping rubber bearing for seismic isolation vol.20, pp.3, 2016, https://doi.org/10.12989/sss.2017.20.3.303
- Seismic response variation of multistory base-isolated buildings applying lead rubber bearings vol.21, pp.5, 2016, https://doi.org/10.12989/cac.2018.21.5.495
- Deformation and failure mechanism exploration of surrounding rock in huge underground cavern vol.72, pp.2, 2016, https://doi.org/10.12989/sem.2019.72.2.275
- Investigation of rotation and shear behaviours of complex steel spherical hinged bearings subject to axial tensile load vol.73, pp.2, 2020, https://doi.org/10.12989/sem.2020.73.2.123
- Seismic Control Strategy of a Multi-Story Subway Station Based on Probability Density Evolution Method vol.17, pp.5, 2016, https://doi.org/10.1142/s0219876219400140
- A Novel Negative Stiffness Amplification System Based Isolation Method for the Vibration Control of Underground Structures vol.10, pp.16, 2016, https://doi.org/10.3390/app10165421
- Seismic Reduction Effectiveness of Friction Pendulum Bearings in Underground Station Structures vol.18, pp.3, 2021, https://doi.org/10.1142/s021987622041008x
- Sensitivity analysis to determine seismic retrofitting column location in reinforced concrete buildings vol.78, pp.1, 2021, https://doi.org/10.12989/sem.2021.78.1.077
- Research on Seismic Reduction and Isolation Measures for Urban Underground Station Structure vol.15, pp.3, 2016, https://doi.org/10.1142/s1793431121500123
- A resilient column with angular friction damper for seismic performance upgrading of underground structures vol.116, pp.None, 2016, https://doi.org/10.1016/j.tust.2021.104085
- Novel seismic design solution for underground structures. Case study of a 2-story 3-bay subway station vol.153, pp.None, 2016, https://doi.org/10.1016/j.soildyn.2021.107087
- Upgrading seismic performance of underground frame structures based on potential failure modes vol.153, pp.None, 2022, https://doi.org/10.1016/j.soildyn.2021.107116