DOI QR코드

DOI QR Code

Seismic performance of prefabricated bridge columns with combination of continuous mild reinforcements and partially unbonded tendons

  • Koem, Chandara (Department of Civil Engineering, Chung-Ang University) ;
  • Shim, Chang-Su (Department of Civil Engineering, Chung-Ang University) ;
  • Park, Sung-Jun (Department of Civil Engineering, Chung-Ang University)
  • 투고 : 2015.11.19
  • 심사 : 2016.02.17
  • 발행 : 2016.04.25

초록

Prefabricated bridge substructures provide new possibility for designers in terms of efficiency of creativity, fast construction, geometry control and cost. Even though prefabricated bridge columns are widely adopted as a substructure system in the bridge construction project recently, lack of deeper understanding of the seismic behavior of prefabricated bridge substructures cause much concern on their performance in high seismic zones. In this paper, experimental research works are presented to verify enhanced design concepts of prefabricated bridge piers. Integration of precast segments was done with continuity of axial prestressing tendons and mild reinforcing bars throughout the construction joints. Cyclic tests were conducted to investigate the effects of the design parameters on seismic performance. An analytical method for moment-curvature analysis of prefabricated bridge columns is conducted in this study. The method is validated through comparison with experimental results and the fiber model analysis. A parametric study is conducted to observe the seismic behavior of prefabricated bridge columns using the analytical study based on strain compatibility method. The effects of continuity of axial steel and tendon, and initial prestressing level on the load-displacement response characteristics, i.e., the strain of axial mild steels and posttensioned tendon at fracture and concrete crushing strain at the extreme compression fiber are investigated. The analytical study shows the layout of axial mild steels and posttensioned tendons in this experiment is the optimized arrangement for seismic performance.

키워드

과제정보

연구 과제번호 : 부분 조립 및 교체가 가능한 지능형 급속시공 기술 개발

참고문헌

  1. AASHTO. (2007), AASHTO LRFD bridge specification (4th Ed.).
  2. Billington, S., Barnes, R. and Breen, J. (2001), "Alternate substructure systems for standard highway bridges", J. Bridge Eng.-ASCE, 6(2), 87-94. https://doi.org/10.1061/(ASCE)1084-0702(2001)6:2(87)
  3. Billington, S. and Yoon, J. (2004), "Cyclic response of unbonded posttensioned precast columns with ductile fiber-reinforced concrete", J. Bridge Eng.-ASCE, 9(4), 353-363. https://doi.org/10.1061/(ASCE)1084-0702(2004)9:4(353)
  4. Bu, Z.Y. and Ou, Y.C. (2013), Simplified Analytical Pushover Method for Precast.
  5. Chiewanichakorn, M. and Aref, A. (2006), "Finite element simulations of seismic response of precast concrete segmental columns", Struct. Cong.-ASCE, 1-9.
  6. Eurocode 2 (prEN 1992-1-1), "Design of reinforced concrete structure", CEN-European Committee for standardization.
  7. Hewes, J.T. and Priestly, M.J.N. (2002), Seismic design and performance of segmental precast concrete column, Report No. SSRP-2001/25, University of California, San Diego, CA.
  8. Moon, D.Y., Roh, H. and Cimellaro, G.P. (2015), "Seismic performance of segmental rocking column connection with NITI Martensitic SMA bars", Adv. Struct. Eng., 18(4), 571-584. https://doi.org/10.1260/1369-4332.18.4.571
  9. Nikbakht, E., Rashida, K., Hejazib, K. and Osmana, S.A. (2014), "A numerical study on seismic response of self-centering precast segmental columns at different post-tensioning forces", Latin Am. J. Solids Struct., 864-883.
  10. Ou, Y.C., Chiewanichakorn, M., Aref, A.J. and Lee, G.C. (2007), "Seismic performance of segmental precast unbonded posttensioned concrete bridge columns", J. Struct. Eng.-ASCE, 133(11), 1636-1647. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:11(1636)
  11. Ou, Y.C., Wang, P.H., Chang, K.C. and Lee, G.C. (2010), "Large-scale experimental study of precast segmental unbonded posttensioned concrete bridge columns for seismic regions", J. Struct, Eng.-ASCE, 136(3), 255-264. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000110
  12. Shim, C.S., Chung, C.S. and Kim, H.H. (2008), "Experimental evaluation of seismic performance of precast segmental bridge piers with a circular solid section", Eng. Struct., 30(12), 3782-3792. https://doi.org/10.1016/j.engstruct.2008.07.005
  13. Shim, C.S., Chung, Y.S. and Han, J.H. (2008), "Cyclic response of Concrete-encased composite columns with low steel ratio", Structure and buildings, Proc. Of the institution of Civil Engineers, 161, Issue SB2, 2008, 77-89.
  14. Shim, C.S., Chung, Y.S. and Yoon, J.Y. (2011), "Cyclic behavior of prefabricated circular composite columns with low steel ratio", Eng. Struct., 30(11), 2525-2534.
  15. Shim, C.S., Kim, D.W. and Kong, D. (2012), "Structural performance of precast segmental composite pier cap", Proceedings of the 18th Congress of International Association for Bridge and Structural Engineering.
  16. Shim, C.S., Park, S.J, Lee, S.Y. and Keom, C. (2015), "Enhanced design of precast concrete columns by optimal axial steels", Earthquake Resistant Engineering Structure X, (152), 267-273
  17. Shim, C.S., Lee, S.Y., Park, S.Y. and Koem, C. (2015), "Cyclic tests on prefabricated bridge piers", Proceedings of the advances in structural Engineering and Mechanics (ASEM15).
  18. Sideris, P., Aref, A.J. and Filiatrault, A. (2014a), "Quasi-static cyclic testing of a large-scale hybrid sliding-rocking segmental column with slip-dominant joints", J. Bridge Eng.-ASCE, 19(10), 04014036. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000605
  19. Sideris, P., Aref, A.J. and Filiatrault, A. (2014b), "Large-scale seismic testing of a hybrid sliding-rocking Posttensioned segmental bridge system", J. Struct, Eng.-ASCE, 140(6), 04014025. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000961
  20. Sideris, P., Aref, A.J. and Filiatrault, A. (2015), "Experimental seismic performance of a hybrid sliding-rocking bridge for various specimen configurations and seismic loading conditions", J. Bridge Eng.-ASCE, 20(11), 04015009. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000742

피인용 문헌

  1. Experiments on prefabricated segmental bridge piers with continuous longitudinal reinforcing bars vol.132, 2017, https://doi.org/10.1016/j.engstruct.2016.11.070
  2. Seismic performance of repaired severely damaged precast columns with high-fiber reinforced cementitious composites 2018, https://doi.org/10.1007/s12205-017-1414-z
  3. Quantitative Definition of Seismic Performance Levels for Precast Bridge Piers with Continuous Reinforcement vol.2020, pp.None, 2016, https://doi.org/10.1155/2020/4087532