DOI QR코드

DOI QR Code

A Study on Freezing Assessment of the Water in the Z-Trap of Sewage Bay

PVC 오수받이 내부 Z형 트랩의 동결성 평가에 관한 연구

  • Lee, Changwoo (Dept. of Fire & Disaster Protection Eng. ineering, Korea Soongsil Cyber Univ.) ;
  • Oh, Seungju (Department of Architecture, University of Kwangwoon)
  • Received : 2016.03.11
  • Accepted : 2016.03.27
  • Published : 2016.03.31

Abstract

This study clarifies the simulation on freezing of remaining water in the Z-trap set up in the PVC sewage bay to control malodor. It made use of commercial FEM LAB program(ver. 3.2) well known as a solution of the problems arising in the flow of various fluid, heat transfer and mass transfer. Simulation results under the temperature $-20^{\circ}C$ outwards show that the water in the Z-trap set up in the sewage bay to control malodor freeze in the 60cm under the ground level after 14 days in the wet ground, and after 17 days in the regular ground. On the other hand, if the soil is dry even after the 42 days does not go down below freezing. Therefore, the water in the Z-trap was confirmed that it does not freeze.

본 연구에서는 PVC 오수받이를 대상으로 상용 프로그램인 FEM LAB(ver. 3.2)을 이용하여 여러 시공 환경조건에서 오수받이 내부에 설치된 악취방지용 Z형 트랩 내부에 잔류하고 있는 물의 겨울철 동결여부를 평가하였다. 시뮬레이션 결과 외부온도 $-20^{\circ}C$가 42일간 지속되더라도 토양이 건조한 상태라면 Z형 트랩에 남아 있는 물이 동결되지 않음을 알 수 있다. 토양이 습윤 상태일 경우 약 14일 정도, 토양이 일반상태의 경우 약 17일 정도가 지나면 Z형 트랩이 위치한 지면으로부터 60cm 지점이 Z형 트랩 내에 동결될 가능성이 있으나, 토양이 건조한 상태에 있을 경우에는 42일이 지나도 지면으로부터 60cm 지점은 영상의 온도를 유지하는 것으로 보아 Z형 트랩 내에 있는 물이 동결되지 않는다는 것을 알 수 있다.

Keywords

References

  1. C. S. Lee, D. S. Shin, H. D. Lee(2015), Study on Seismic Fragility Analysis of Water Supply Facilities, Journal of the Korean Society of Disaster Information, Vol. 11 No.1, pp. 35-43 https://doi.org/10.15683/kosdi.2015.11.1.35
  2. C. H. Choi (2005), A Study on Efficient Maintenance and Management of the Sewage Conduits in Korea, Yonsei University.
  3. D. H. Ahn (2010), The Major Problems and Improvement in Drainage Facility for Sewer Rehabilitation, Gyeongsang National University.
  4. H. J. Park (2011), Improvement for Asset Management of Sewage Treatment Facilities, Journal of the Korean Society of Civil Engineers, 31(2D), pp. 285-293.
  5. K. S. Kim (2000), Consideration for the Performance of Functional Improvement in the Sewer System, Seoul Urban Research, 1(2), pp. 49-64.
  6. Ministry of Environment(MOE) (2005), Practice Guideline for Public Sewer Maintenance & Repair.
  7. Ministry of Environment(MOE) (2010), Standard Output Specification for BTL Sewerage Projects.
  8. Ministry of Public Administration and Security(MOPAS) (2012), Accounting and financial Reporting Regulation for Local Government.
  9. Ministry of Strategy and Finance(MOSF) (2012), Submitting The National Financial Statement of 2011 Fiscal Year to The National Assembly, Press Release of 31th, May, 2012 (in Korean).
  10. S. I. Lim (2000), The Principles, Strategies for Reforming the Budgeting and Accounting System in the Korean Local Governments, the Korea Local Administration Review, 14(1), pp. 1-30.