DOI QR코드

DOI QR Code

Design of a Three-Axis Force Sensor for Finger Force Measuring System

손가락 힘측정장치의 3축 힘센서 설계

  • Lee, Kyeong-Jun (Department of Control & Instrumentation Engineering, ERI, Gyeongsang National Unversity) ;
  • Kim, Gab-Soon (Department of Control & Instrumentation Engineering, ERI, Gyeongsang National Unversity)
  • Received : 2015.11.01
  • Accepted : 2016.01.19
  • Published : 2016.03.31

Abstract

This paper describes the design and fabrication of a three-axis force sensor with three parallel plate structures(PPSs) for measuring force in a finger force measuring system for a spherical object catch. The three-axis force sensor is composed of a Fx force sensor, Fy force sensor and a Fz force sensor, and the elements of Fx force sensor and Fy force sensor are a parallel plate structure(PPS) respectively and Fz force sensor is two PPS. The three-axis force sensor was designed using FEM(Finite Element Method), and manufactured using strain-gages. The characteristics test of the three-axis force sensor was carried out. As a test results, the interference error of the three-axis force sensor was less than 1.32%, the repeatability error of each sensor was less than 0.04%, and the non-linearity was less than 0.04%.

Keywords

References

  1. H.M Kim, G.S. Kim, "Judgment method of the rehabilitation extent using a spherical type digital finger force measuring system", Korean Society Precision Engineering, Vol. 31, No. 8, pp. 729-735, 2014. https://doi.org/10.7736/KSPE.2014.31.8.729
  2. G.S. Kim, "Development of a hook-ype finger force measuring system with force sensors", Journal of Institute of Control, Robotics and Systems, Vol. 20, No. 6, pp. 663-668, 2014. https://doi.org/10.5302/J.ICROS.2014.13.1978
  3. G.S. Kim, "Quantitative Evaluation of rehabilitation therapy based on a two-finger force measurement system", Journal of Sensor Science and Technology, Vol. 23, No. 6, pp. 357-361, 2014. https://doi.org/10.5369/JSST.2014.23.6.357
  4. G.S. Kim, "Development of finger-force measuring system of a cylindrical-type", Journal of Sensor Science and Technology, Vol. 19, No. 5, pp.349-355, 2010. https://doi.org/10.5369/JSST.2010.19.5.349
  5. G.S. Kim, "Development of cylindrical-type finger force measuring system using two-axis force/moment sensor and its characteristic evaluation", Journal of Institute of Control, Robotics and Systems, Vol. 17, No. 5, pp.484-489, 2011. https://doi.org/10.5302/J.ICROS.2011.17.5.484
  6. L. Pan, A. Song, G. Xu, H. Li, H. Zeng and B. Xu, "Safety supervisory strategy for an upper-limb rehabilitation robot based on impedance control", Int. J. Adv. Robot. Syst., Vol. 10, pp. 1-12, 2013. https://doi.org/10.5772/52938
  7. P. R. Culmer, A. E. Jackson, S. Makower, R. Richardson, J. A. Cozens, M. C. Levesley, and B. B. Bhakta, "A control strategy for upper limb robotic rehabilitation with a dual robot system", IEEE-ASME Trans. Mechatron., Vol. 15, No. 4, pp. 575-585, 2010. https://doi.org/10.1109/TMECH.2009.2030796
  8. H. C. Kim, L. M. Miller, I. Fedulow, M. Simkins, G. M. Abrams, N. Byl, and J. Rosen, "Kinematic data analysis for post-stroke patients following bilateral versus unilateral rehabilitation with an upper limb wearable robotic system", IEEE Trans. Neural Syst. Rehabil. Eng., Vol. 21, No. 2, 2013.
  9. C. Li, Y. Inoue, T. Liu, K. Shibata and K. Oka, "A self-controlled robot for upper limb rehabilitation", Proceedings of the 2010 IEEE International Conference on Information and Automation(ICIA), pp. 115-118, 2010. June 20-23, Harbin, China
  10. K. Nagai, Y. Ito, M. Yazaki, K. Higuchi and S. Abe, "Development of a small Six-component force/torque sensor based on the double-cross structure", Adv. Robot., Vol. 22, No. 3, pp. 361-369, 2004.
  11. ATI Industrial Automation, "Multi-axis force/torque sensor", ATI Industrial Automation, pp. 4-45, 2005.
  12. G. S. Kim and J. W. Yoon, "Development of calibration system for multi-axis force/moment sensor and its uncertainty evaluation", Int. J. Precis. Eng. Mannt., Vol. 24, No. 10, pp. 91-98, 2007.