DOI QR코드

DOI QR Code

Ultrasound Phantoms to Protect Patients from Novices

  • Kim, Young Hoon (Department of Anesthesiology and Pain Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea)
  • 투고 : 2016.01.06
  • 심사 : 2016.03.14
  • 발행 : 2016.04.01

초록

With the growing use of ultrasound for pain management, we are interested in how to teach and practice ultrasound-guided procedures. Ethically, we should not insert a needle in a patient until after much practice on a phantom. Several types of phantoms have been introduced for ultrasound training, including water, agar/gelatin, elastomeric rubber, and meat phantoms and cadavers. The ideal phantom is similar to human tissue, is readily available and inexpensive, can be used repeatedly, provides tactile feedback, will hold a needle in place, does not generate needle tracks, and is not a health hazard. Several studies have shown the effectiveness of phantoms for improving the proficiency of novices. We hope that the application of phantoms in education leads to improved proficiency and increased patient safety.

키워드

참고문헌

  1. Bellingham GA, Peng PW. A low-cost ultrasound phantom of the lumbosacral spine. Reg Anesth Pain Med 2010; 35: 290-3. https://doi.org/10.1097/AAP.0b013e3181c75a76
  2. Eastwood CB, Moore DL. A simple, inexpensive model for the practice of ultrasound-guided regional anesthesia techniques. Reg Anesth Pain Med 2010; 35: 323-4. https://doi.org/10.1097/AAP.0b013e3181d236c8
  3. Hocking G, Hebard S, Mitchell CH. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia. Reg Anesth Pain Med 2011; 36: 162-70. https://doi.org/10.1097/AAP.0b013e31820d4207
  4. Michalek P, Donaldson W, McAleavey F, Johnston P, Kiska R. Ultrasound imaging of the infraorbital foramen and simulation of the ultrasound-guided infraorbital nerve block using a skull model. Surg Radiol Anat 2013; 35: 319-22. https://doi.org/10.1007/s00276-012-1039-3
  5. Karmakar MK, Li X, Kwok WH, Ho AM, Ngan Kee WD. Sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region. Br J Radiol 2012; 85: e262-9. https://doi.org/10.1259/bjr/93508121
  6. Gibson RN, Gibson KI. A home-made phantom for learning ultrasound-guided invasive techniques. Australas Radiol 1995; 39: 356-7. https://doi.org/10.1111/j.1440-1673.1995.tb00311.x
  7. Di Domenico S, Santori G, Porcile E, Licausi M, Centanaro M, Valente U. Inexpensive homemade models for ultrasoundguided vein cannulation training. J Clin Anesth 2007; 19: 491-6. https://doi.org/10.1016/j.jclinane.2007.05.002
  8. Li JW, Karmakar MK, Li X, Kwok WH, Ngan Kee WD. Gelatin-agar lumbosacral spine phantom: a simple model for learning the basic skills required to perform real-time sonographically guided central neuraxial blocks. J Ultrasound Med 2011; 30: 263-72. https://doi.org/10.7863/jum.2011.30.2.263
  9. Brascher AK, Blunk JA, Bauer K, Feldmann R Jr, Benrath J. Comprehensive curriculum for phantom-based training of ultrasound-guided intercostal nerve and stellate ganglion blocks. Pain Med 2014; 15: 1647-56. https://doi.org/10.1111/pme.12365
  10. Morehouse H, Thaker HP, Persaud C. Addition of Metamucil to gelatin for a realistic breast biopsy phantom. J Ultrasound Med 2007; 26: 1123-6. https://doi.org/10.7863/jum.2007.26.8.1123
  11. Chao SL, Chen KC, Lin LW, Wang TL, Chong CF. Ultrasound phantoms made of gelatin covered with hydrocolloid skin dressing. J Emerg Med 2013; 45: 240-3. https://doi.org/10.1016/j.jemermed.2012.11.022
  12. Hocking G, McIntyre O. Achieving change in practice by using unembalmed cadavers to teach ultrasound-guided regional anaesthesia. Ultrasound 2011; 19: 31-5. https://doi.org/10.1258/ult.2010.010040
  13. West SJ, Mari JM, Khan A, Wan JH, Zhu W, Koutsakos IG, et al. Development of an ultrasound phantom for spinal injections with 3-dimensional printing. Reg Anesth Pain Med 2014; 39: 429-33. https://doi.org/10.1097/AAP.0000000000000136
  14. Mendiratta-Lala M, Williams T, de Quadros N, Bonnett J, Mendiratta V. The use of a simulation center to improve resident proficiency in performing ultrasound-guided procedures. Acad Radiol 2010; 17: 535-40. https://doi.org/10.1016/j.acra.2009.11.010
  15. Moore DL, Ding L, Sadhasivam S. Novel real-time feedback and integrated simulation model for teaching and evaluating ultrasound-guided regional anesthesia skills in pediatric anesthesia trainees. Paediatr Anaesth 2012; 22: 847-53. https://doi.org/10.1111/j.1460-9592.2012.03888.x
  16. Kwon SY, Hong SH, Kim ES, Park HJ, You Y, Kim YH. The efficacy of lumbosacral spine phantom to improve resident proficiency in performing ultrasound-guided spinal procedure. Pain Med 2015; 16: 2284-91. https://doi.org/10.1111/pme.12870

피인용 문헌

  1. A pictorial review of signature patterns living in musculoskeletal ultrasonography vol.29, pp.4, 2016, https://doi.org/10.3344/kjp.2016.29.4.217
  2. Special Ultrasound Phantom for Interventional Training: Construction, Advantages, and Application vol.26, pp.4, 2016, https://doi.org/10.4103/jmu.jmu_40_18
  3. Silicone-based composite materials simulate breast tissue to be used as ultrasonography training phantoms vol.88, pp.None, 2016, https://doi.org/10.1016/j.ultras.2018.03.001
  4. The efficacy of cervical spine phantoms for improving resident proficiency in performing ultrasound-guided cervical medial branch block : A prospective, randomized, comparative study vol.97, pp.51, 2018, https://doi.org/10.1097/md.0000000000013765
  5. Current status of pain medicine training in anesthesiology and pain medicine residency programs in university hospitals of Korea: a survey of residents’ opinions vol.45, pp.4, 2020, https://doi.org/10.1136/rapm-2019-100995
  6. Making a convenient, low‐cost phantom with a previously unreported material for practicing ultrasound‐guided procedures vol.49, pp.9, 2016, https://doi.org/10.1002/jcu.23065