DOI QR코드

DOI QR Code

An Experimental Study on the Fatigue Behavior of T-Type Tension Joints with High Tension Bolt

고장력볼트 T-인장이음의 피로거동에 관한 실험적 연구

  • Lee, Seung Yong (Dept. of Civil Engineering, Korea National University of Transportation) ;
  • Choi, Jun Hyeok (Dept. of Civil Engineering, Bucheon University)
  • Received : 2016.10.11
  • Accepted : 2016.11.01
  • Published : 2016.12.27

Abstract

In this paper, it was performed the fatigue test to examine the effect of cyclic loading for the simple T-joint. Axial force of bolt by clamping and the change of the force by applied load were measured in the joint. And the bolt force, the failure mode and the fatigue strength under cyclic loading were investigated. The parameters of the tension joint were set to be the flange thickness and the diameter of bolt to a different stiffness of the joint in response to the combination. From the fatigue test, failure mode of tensile joints under cyclic loading could be evaluated using a static ultimate load of the specific failure mode in EC3. The fatigue strength of the tension joints was considerably higher than the fatigue strength of the EC3(36) that does not consider a lever action. However, the additional axial force by lever action occurs to an increase in the axial force of the bolt it requires a careful evaluation of the fatigue strength.

본 연구에서는 인장이음에 대한 반복하중의 영향을 파악하기 위하여 단순 인장이음을 대상으로 피로시험을 수행하였다. 인장이음의 볼트체결에 따른 축력과 작용하중에 의한 축력의 변화를 측정하였고 반복하중에 의한 볼트의 축력과 파괴양상, 이음의 피로강도를 조사하였다. 인장이음의 구조 상세 변수는 플랜지 두께와 고장력 볼트의 직경으로서 이들의 조합에 따라 볼트와 연결부의 강성이 달라지도록 하였다. 피로시험결과, 반복하중을 받는 인장이음의 파괴모드는 EC3에서 제시하고 있는 정적 파괴모드별 극한하중을 이용하여 평가될 수 있었다. 인장이음의 피로강도는 지레작용을 고려하지 않은 EC3(36)의 피로강도보다 상당히 안전측의 결과로 나타났다. 그러나, 지레작용에 의한 부가축력은 볼트 축력의 증가를 일으키기 때문에 피로강도에 대한 신중한 평가가 필요하다.

Keywords

References

  1. Struik, J.H.A. (1969) Tests on Bolted T-stubs with Respect to a Bolted Beam-to-column Connections, Report 6-69-13, Stevin Laboratory, Deft University of Technology, Delft, the Netherlands.
  2. Fisher, J.W. and Struik, J.H.A. (1973) Guide to Design Criteria for Bolted and Riveted Joints, John Wiley & Sons, pp.257-280.
  3. Kulak, G.L., Fisher, J.W., and Struik, J.H.A. (1987) Guide to Design Criteria for Bolted and Riveted Joints, 2nd Edition, John Wiley & Sons, pp.268-288.
  4. AASHTO (1998) AASHTO LRFD Bridge Design Specification, Second edition, SI units.
  5. AISC (1980) Manual of steel construction, part 4, connections, pp.4-88-4-93.
  6. Eurocode (1992), Design of steel structures.
  7. 최혜경, 최성모, 김진호(2003) 고력볼트 Split Tee 접합부의 인장내력, 한국강구조학회 논문집, 한국강구조학회, 제15권, 제5호, pp.541-549. Choi, H.K., Choi, S.M., and Kim, J.H. (2003) Structural Tensile Capacities of Split-Tee Connection with High Stength Bolts, Journal of Korean Society of Steel Construction, KSSC, Vol.15, No.5, pp.541-549 (In Korean).
  8. 최성모, 이성희, 김진호(2004) 고력볼트 스플릿-티 인장접합부의 구조성능에 관한 실험적 연구, 한국강구조학회 논문집, 한국강구조학회, 제16권, 제6호, pp.737-745. Choi, S.M., Lee, S.H., and Kim, J.H.(2004) An Experimental Study on the Structural Characteristics of Tension Joints with High- Stength Bolted Split-Tee Connection, Journal of Korean Society of Steel Construction, KSSC, Vol.16, No.6, pp.737-745 (In Korean).
  9. 양재근, 백민창(2013) 고력볼트로 체결된 T-sub의 지레작용력 및 부재 접촉력 예측모델, 한국강구조학회논문집, 한국강구조학회, 제25권, 제4호, pp.409-419. Yang, J.G. and Baek, M.C. (2013) Prediction Models for the Prying Action Force and Contact Force of a T-stub Fastened by High-Strength Bolts, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.4, pp.409-419 (in Korean).