References
- American Institute of Steel Construction, Inc. (AISC) (2005), Seismic Provisions for structural steel buildings, Standard ANSI/AISC 341-05, Chicago, IL.
- Arce, G. (2002), "Impact of higher strength steels on local buckling and overstrength of links in eccentrically braced frames", M.Sc. Thesis, Univ. of Texas at Austin, Austin.
- Berman, J.W. and Bruneau, M. (2007), "Experimental and analytical investigation of tubular links for eccentrically braced frames", Eng. Struct., 29(8), 1929-1938. https://doi.org/10.1016/j.engstruct.2006.10.012
- Drolias, A. (2007), "Experiments on link-to-column connections in steel eccentrically braced frames", M.Sc. Thesis, Department of Civil Engineering, University of Texas at Austin, Austin.
- Federal Emergency Management Agency (FEMA) (2000), Recommended seismic design criteria for steel moment-frame buildings, Publication FEMA-350, Washington DC.
- Okazaki, T., Engelhardt, M., Drolias A., Schell, E., Hong, J. and Uang, C. (2009), "Experimental investigation of link-to-column connections in eccentrically braced frames", J. Constr. Steel Res., 65(7), 1401-1412. https://doi.org/10.1016/j.jcsr.2009.02.003
- Okazaki, T. and Engelhardt, M. (2007), "Cyclic loading behavior of EBF links constructed of ASTM A992 steel", J. Constr. Steel Res., 63(6), 751-765. https://doi.org/10.1016/j.jcsr.2006.08.004
- Okazaki, T., Engelhardt, M.D., Nakashima, M. and Suita, K. (2006), "Experimental performance of link-tocolumn connections in eccentrically braced frames", J. Struct. Eng., 132(8), 1201-1211. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:8(1201)
- Okazaki, T., Engelhardt, M., Nakashima, M. and Suita, K. (2004), "Experimental study on link-to-column connection steel eccentrically braced frames", 13th World Conference on Earthquake Engineering, Vancouver, Canada, August.
- Prinz, G.S. and Richards, P. (2009), "Eccentrically braced frame links with reduced web sections", J. Constr. Steel Res., 65(10-11), 1971-1978. https://doi.org/10.1016/j.jcsr.2009.04.017
- Richards, P.W. and Uang, C.M. (2005), "Effect of flange width thickness ratio on eccentrically braced frame link cyclic", J. Struct. Eng., 131(10), 1546-1552. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:10(1546)
- Richards, P. and Uang, C.M. (2004), "Development of testing protocol for links in eccentrically braced frames", 13th World Conference on Earthquake Engineering, Vancouver, Canada, August.
Cited by
- Residual stress effect on link element of eccentrically braced frame vol.128, 2017, https://doi.org/10.1016/j.jcsr.2016.09.006
- Experimental assessment of I-shaped steel beams with longitudinal stiffeners under lateral-torsional buckling vol.85, pp.207, 2018, https://doi.org/10.15446/dyna.v85n207.71892
- Study of the Behavior of Beam-to-Column Moment Connections with Tapered Beams vol.44, pp.suppl1, 2020, https://doi.org/10.1007/s40996-020-00369-x
- Optimized stiffener detailing for shear links in eccentrically braced frames vol.39, pp.1, 2016, https://doi.org/10.12989/scs.2021.39.1.035