Abstract
In this study, The watertight damper was designed to improve conventional DN 350A butterfly valve. The FSI(Fluid-Structure Interaction) analysis has performed to investigate the safety factor for the watertight damper. When watertight damper of disk was closed, the disk of pressure value is constant. However depending on the opening angle of disk, the flow velocity and pressure are changed. The maximum velocity was appeared at the end of disk on the small outlet area of duct. When the opening angel of disk is $90^{\circ}$, the maximum velocity was appeared at the center of ending disk. So we were found the opening angle of disk is bigger, the flow rate is increased and velocity is also increased from the result of FSI analysis. We can find the least deformation and stress when the opening angel of damper is $90^{\circ}$. When the $45^{\circ}$ opening angle of disk, the largest deformation and stress was found and the minimum safety factor 1.3 was calculated. As a result, we found that the structure of watertight damper is safe enough irrespective of opening angel.