DOI QR코드

DOI QR Code

Charge Copy Method for Reduction of Cross Regulation in SIDO Boost Converter

SIDO boost converter에서 크로스 레귤레이션을 줄이기 위한 전하 복사방법

  • Hwang, Wonjune (Dept. of Electrical and Electronics Engineering, Chung-Ang University) ;
  • Kim, Ju Eon (Dept. of Electrical and Electronics Engineering, Chung-Ang University) ;
  • Baek, Kwang-Hyun (Dept. of Electrical and Electronics Engineering, Chung-Ang University)
  • Received : 2016.12.22
  • Accepted : 2016.12.27
  • Published : 2016.12.31

Abstract

In conventional SIDO(Single Inductor Dual Output) boost converter, charging time is changed by load power consumption. In this case, if the power consumption of one load is changed to such a degree that switching frequency of the boost converter must be changed, another load charge time is also changed, which this causes cross regulation. In this paper, the charge copy technique is proposed to reduce cross regulation. When the switching frequency is changed to an integer ratio, another load charge time is also changed to integer ratio. Simulation result shows that proposed method reduces the 10.24mV cross regulation and 39.118us recover-time compared with conventional method.

기존 SIDO(Single Inductor Dual Output) boost converter에서는 전력 사용량의 변화에 맞게 부하에 전하를 공급하는 시간을 바꾸게 된다. 이 때 boost converter의 스위칭 주파수가 변해야 할 정도로 어느 한 부하의 전력 사용량이 크게 바뀔 경우, 나머지 부하에 전하를 공급하는 시간도 바뀌게 된다. 이로 인해 크로스 레귤레이션이 일어난다. 따라서 본 논문에서는 어느 한 부하의 전력 사용량의 변화로 스위칭 주파수가 정수 비로 바뀔 때 나머지 부하에 전하를 공급하는 시간도 같은 정수 비로 변화 시킨다. 이 방법을 전하 복사기법(charge copy)이라 하며 이 효과로 인하여 크로스 레귤레이션이 감소한다. 제안하는 방법의 시뮬레이션 결과로 크로스 레귤레이션이 기존의 방법보다 10.42mV/A 만큼 감소하고, 복원 시간은 39.118us 만큼 작아지는 결과를 보였다.

Keywords

References

  1. Xiaochen Jing, Philip K. T. Mok, M.C.Lee "Awide-Load-Range Constant-Charge Auto Hopping Control single-Inductor-Dual-Output Boost Regulator With Minimized Cross-Regulation," IEEE J. Solid-State Circuits, vol.46, no.10, pp.2350-2362,Oct.2011. https://doi.org/10.1109/JSSC.2011.2162188