참고문헌
- Chang, S.M. (2015). A Study on the Influence of the Exterior Waterproofing Method in the Condensation Environment of the Below-Grade Structure, Department of Energy and Environmental Engineering, Graduate School, Seoul National University of Science and Technology [in Korean].
- Choi, I.H., Lee, J.H., Kim, Y.R., Kim, U.J. (2011). "An experimental study on the improvement for quality of waterproofing method for underground parking lot," Annual Conference Journal of the Architectural Institute of Korea, 31(1), 119-120 [in Korean].
- Choi, S.M. (2015). Effect of application and case study of water liquid in below-grade structure of apartment house, Journal of the Architectural Institute of Korea, 59(9), 58-62 [in Korean].
- Choi, S.M., Kim, M.J., Jang, S.M., Jang, D.B., Oh, S.K. (2014). "Consideration for the necessity of the exterior waterproofing on the below grade parking lot of the apartment house," Annual Conference Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, 222-223 [in Korean].
- Eom, T.H., Kim, Y.S., Shin, H.C., Kim, Y.G. (2015). "A study on the quality standard and basic physical properties for underground structure outer side waterproofing," Developmental Direction for Synthetic Polymer Seal Waterproofing Materials for the Underground Exterior Wall, Annual Conference Jourmal of Korea Recycled Construction Resource Institute, 15(1), 367-370 [in Korean].
- Kang, C.H., Kim, Y.S. (2001). "The current status and case studies on the waterproofing defects in the underground parking lot of apartment buildings," Annual Conference Journal of the Architectural Institute of Korea, 21(2), 503-506 [in Korean].
- Kim, Y.G. (2002). A Study on the Defect of Waterproofing and Repair Method in Apartment Housing, Master's Thesis, Yonsei University [in Korean].
- Ma, S.J., Han, Y.J., Lee, J.H., Song, J.Y., Oh, S.K. (2015). "Technical applicability of exterior waterproofing method used in domestic underground structures," Annual Conference Journal of the Korean Recycled Construction Resources Institute, 15(2), 298-299 [in Korean].
- Min, B.Y., Kim, S.W., Lee, M.H., Lee, J.H., Kwon, K.J. (1994). Improvement of underground waterproof for RC structures, Journal of Korea Concrete Institute, 6(1) [in Korean].
- Oh, S.K. (2015). The necessity of water-leakage prevention system status and design criterion for apartment house underground structure, Journal of the Architectural Institute of Korea, 59(9), 52-57 [in Korean].
- Oh, S.K., Choi, S.M., Song, J.Y. (2014). Analysis of the cause of waterleakage in residential apartment underground parking ground and the review of the repare methods, Journal of the Korean Recycled Construction Resources Institute, 2(3), 255-264 [in Korean]. https://doi.org/10.14190/JRCR.2014.2.3.255