Abstract

To find the buried pipes and cavities, GPR detection were proceed by the type and depth of underground pipes and cavities buried in the Chamber. In the case of asphalt pavement and non-pavement, the exploration of buried pipe were easy than the concrete and reinforced concrete pavement. In the case of air cavity, the buried depth of 1 m was evaluated as the detection was possible.

본 연구에서는 토조에 설치한 관의 종류 및 매립 깊이, 공동 깊이 및 포장 조건 등에 대한 GPR(Ground Penetrating Radar) 탐사를 진행하여 매립관의 종류 및 공동 탐사 능력을 실험적으로 규명하였다. 아스팔트 포장 및 비포장의 경우, 콘크리트 포장 및 철근 콘크리트 포장 대비 매립관의 탐사가 용이한 것으로 평가되었다. 또한 공기 공동의 경우, 매립 깊이 1 m에서는 탐지가 가능한 것으로 평가되었다.

Keywords

References

  1. Gaballahun, M., and Sato. M. (2009), A New Approach to Enhancement of Ground Penetrating Radar Target Signals by Pulse Compression, Exploration Geophysics, CSIRO., 40, 77-84. https://doi.org/10.1071/EG08120
  2. Geophycical Survey Systems, Inc (2011), SIR System-300 Manual, Geophycical Survey Systems, Inc.
  3. Hyun, S. Y., and Kim. S. Y. (2012), Eigenimage-Based Signal Processing for Subsurface Inhomogeneous Clutter Reduction in Ground-Penetrating Rada Images, Journal of Korean Institute of Electromagnetic Engineering and Science, KIEES., 23(11), 1307-1314. https://doi.org/10.5515/KJKIEES.2012.23.11.1307
  4. Jung, H. C., Hwang, W. K., Kim, W. D., and Han, S. J. (2007), The porosity detection aside of pipewall using GPR, Joint proceedings of 2007 KSWW & KSWERA Symposium, Korean Society of Water and Wastewater and Korean Society on Water Environment, B58-B63.
  5. Park, I. C., and Cho, W. C. (2006), Detection of the pipe leak for water distribution system using ground penetration radar, Proceedings of 2006 KWRA Symposium, Korea Water Resources Association, 1271-1274.
  6. Yoo, Y. S., Lee, D. Y., Oh, D. W., Kong, S. M., and Lee. Y. J. (2015), Numerical study on application of pseudo-plastic backfill to cavity and relaxed zone around old sewerage, KSCE 2015 Convention of Civil EXPO & Conference, Korea Society of Civil Engineers, 125-126.