Abstract

In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

Keywords

References

  1. Franz, M., Werner, W., and Monika, S. -D., Solar Heat Worldwide: Markets and Contribution to the Energy Supply 2014, IEA Solar Heating & Cooling Programme, 2016.
  2. NEW & RENEWABLE ENERGY Statistics 2014, Korea Energy Agency New & Renewable Energy Center, 2015.
  3. http://www.koenergy.co.kr/news/articleView.html?idxno=71591
  4. Sohn, J. -G., Performance Analysis of Solar Heating System for High Solar Fraction using TRNSYS, Journal of the Korean Solar Energy Society, Vol. 32, No. 3, pp. 59-67, 2012. https://doi.org/10.7836/kses.2012.32.3.059
  5. Baek, N. -C., Han, S. -H., Lee, W. -J., Shin, U. -C., An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 27, No. 11, pp. 581-586, 2015. https://doi.org/10.6110/KJACR.2015.27.11.581
  6. Stephen, H. and Cynthia A. C., A Review of Strategies for the Control of High Temperature Stagnation in Solar Collectors and Systems, Energy Procedia, Vol. 30, pp. 793-804, 2012. https://doi.org/10.1016/j.egypro.2012.11.090
  7. Autodesk, Ecotect Analysis, 2011.
  8. Yoo, J. -H., Hwang, H. -J., and Lee, J. -E., A Comprehensive Validation for Energy Performance of Houses through the Occupant Behavior 1st The Evaluation of Energy consumption and Derive of Reference housing model, Land & Housing Institute, 2016.