DOI QR코드

DOI QR Code

A Study on the Control and Level Measurement for a Rainwater Tank

우수 저류조 수위측정 및 제어에 대한 연구

  • Kim, Kee-Hwan (Department of Electronic Engineering, Semyung University)
  • Received : 2016.09.15
  • Accepted : 2016.10.10
  • Published : 2016.12.30

Abstract

In this paper, we propose a system for monitoring and controlling the level of the rainwater tank by installing an underground storage tank as one of ways to increase the utilization rate to solve the water shortage and imbalance. For this purpose, a microprocessor of ATMEL's Atmega 128 is used for the control module, and the sensor capable of measuring the water level uses a float type level sensor which is a kind of tactile sensor. In particular, the level sensor outputs the output in a industry standard dimension, so that the compatibility is improved so as to replace the existing sensor.

본 논문에서는 물 부족, 불균형을 해결하기 위해 우수 이용률을 높이는 방법의 하나로 지하저류조를 설치하여 빗물을 저장하고, 관리하고자 하는 곳을 위한 저류조 수위의 모니터링과 제어에 대한 시스템을 제안하고 이를 구현하였다. 이를 위해 제어를 위한 모듈에는 ATMEL사의 Atmega 128의 마이크로프로세서를 사용하고 수위를 측정할 수 있는 센서는 접촉식 센서의 일종인 부자형태의 레벨센서를 사용하였다. 특히 레벨센서는 출력을 산업체 일반에서 많이 사용하는 크기로 출력하므로 기존의 센서를 대체할 수 있도록 호환성이 높도록 하였다.

Keywords

References

  1. Mi Na Son, "A Study on the Determining the Tank Size of Rainwater Harvesting System for Apartment House," Master Thesis Konkuk University, p. 18, 2010. 8
  2. POSCO, "A study on the Construction Standardization for Apartment Housing Eco-friendly Rainwater Treatment," POSCO 2008.
  3. K. H. Kim, T. G. Lee, "Rainwater Bank Management System by Using JAVA," The Journal of The Institute of Webcasting, Internet Television and Telecommunication, Vol. 6, No. 3, pp. 55-60, 2006.