참고문헌
- Architectural Institute of Korea (2009) Korean Building Code and Commentary.
- Architectural Institute of Japan (2000) Damping in Building.
- Cho, J.E., You, K.P., Kim, Y.M. (2006) The Evaluation in Wind Vibration Response of Tapered Tall Buildings, J. Archit. Inst. Korea, 22(5), pp.81-88.
- Cho, K.P., Lee, O.J. (2009) Wind-excited Motions of Tall Buildings with Geometrical Shapes, J. Archit. Inst. Korea, 25(6), pp.21-32.
- Cho, J.E., You, J.P., Kim, J.S., Kim, Y.M. (2005) The Evaluation in Displacement Response of Tapered Tall Buildings to Wind Load, J. Korean Assoc. Spat. Struct., 5(4), pp.101-108.
- Cole, H.A. (1968) On-the-line Analysis of Random Vibration, AIAA paper, No.68-288.
- Cole, H.A. (1973) On-line Failure Detection and Damping Measurements of Aerospace Structures by Random Decrement Signature, NASA CR-2205.
- Chung, Y.B. (2001) Reducing Effect of Wind-Induced Vibration on Rectangular Model of Super-Highrise Building with Length of Corners Cutting, J. Korean Soc. Steel Const. 13(3), pp.301-311.
- ESDU 83009 (2012) Damping of Structures, Part 1: Tall Buildings, ESDU International plc, 27 Corsham Street, London N1 6UA.
- Ha, Y.C., Kim, D.W., Jung, P.S. (2002) Wind Tunnel Test Study On The Effective Elevation and Plan Shapes of Super High-Rise Building Resisting Wind-Induced Response-Focused on the Variations of Openings for Building, J. Archit. Inst. Korea, 18(9), pp.93-100.
- Kawai, H. (1998) Effect of Corner Modifications on Aeroelastic Instabilities of Tall Builidng, J. Wind Eng. Ind. Aerodyn. 74-76, pp.719-729. https://doi.org/10.1016/S0167-6105(98)00065-8
- Kim, D.W., Ha, Y.C. (2004) Aerodynamic Methods for Mitigating the Wind-induced Forces on the Tall Buildings, J. Archit. Inst. Korea, 20(11), pp.3-10.
- Kim, W., Kim, Y.C. (2015) Dynamic Responses of Super-tall Buildings Exposed to Various Incident Flows, J. Archit. Inst. Korea, 31(8), pp.19-26.
- Kim, W., Yoshida, A., Tamura, Y. (2015) Correlation Analysis of Aerodynamic Forces Acting onTall Buildings with Various Side Ratios, J. Comput. Struct. Eng. Inst. Korea, 28(2), pp.153-160. https://doi.org/10.7734/COSEIK.2015.28.2.153
- Kim, Y.C. (2012) Evaluation of Wind-induced Responses of Tapered and Setback Tall Buildings, J. Archit. Inst. Korea, 28(12), pp.37-44.
- Kim, Y.C. (2014) Aerodynamic Damping Ratio of Super-Tall Buildings, J. Archit. Inst. Korea, 30(8), pp.29-36.
- Kwok, K.C.S., Wilhelm, P.A., Wilkie, B.G. (1988) Effect of Edge Configuration on Wind-induced Response of Tall Buildings, Eng. Struct,. 10(2), pp.135-140. https://doi.org/10.1016/0141-0296(88)90039-9
- Marukawa, H., Kato, N., Fujii, K., Tamura, Y. (1996) Experimental Evaluation of Aerodynamic Dampnig of Tall Building, J. Wind Eng. Ind. Aerodyn. 59, pp.177-190. https://doi.org/10.1016/0167-6105(96)00006-2
- Quan, Y., Gu, M., Tamura, Y. (2005) Experimental Evaluation of Aerodynamic Damping of Square Super High-rise Buildings, Wind & Struct., 8(5), pp.309-324. https://doi.org/10.12989/was.2005.8.5.309
- Rodrigues, J., Brincker, R. (2005) Application of the Random Decrement Technique in Operational Modal Analysis, Proceedings of the 1st International Operational Modal Analysis Conference, pp.191-200.
- Tamura, Y., Suganuma, S.Y. (1996) Evaluation of Amplitude-Dependent Damping and Naturanl Frequency of Buildings during Strong Winds, J. Wind Eng. Ind. Aerodyn. 59, pp.179-191.
- Tanaka H., Tamura, Y., Ohtake K., Nakai, M., Kim, Y.C. (2012) Experimental Investigation of Aerodynamic Forces and Wind Pressures Acting on Tall Buildings with Various Unconventional Configurations, J. Wind Eng. Ind. Aerodyn. 107-108, pp.179-191. https://doi.org/10.1016/j.jweia.2012.04.014
- Tanaka H., Tamura, Y., Ohtake K., Nakai, M., Kim, Y.C. (2011) Wind Force Characteristics of Tall Buildings with Unconventional Configurations (part 4) Aerodynamic and Response Characteristics of Buildings with Composite Configurations, Annual Meeting of Architectural Institute of Japan, pp.41-42 (in Japanese).
- Vandiver, J.K., Dunwoody, A.B., Campbell, R.B., Cook, M.F. (1982) A mathematical Basis for the Random Decrement Vibration Signature Analysis Technique, J. Mech. Design, 104(2), pp.307-313. https://doi.org/10.1115/1.3256341
- Watanabe, Y., Isyumov, N., Davenport, A.G. (1997) Empirical Aerodynamic Damping Function for Tall Building, J. Wind Eng. Ind. Aerodyn., 72, pp.313-321. https://doi.org/10.1016/S0167-6105(97)00260-2
- You, K.P. (2005) Aerodynamic Across-wind Response of Tapered Tall Building according to Variation of Damping Ratios under Wind Load, J. Archit. Inst. Korea, 21(3), pp.95-101.