DOI QR코드

DOI QR Code

Residual drift analyses of realistic self-centering concrete wall systems

  • Henry, Richard S. (Department Civil and Environmental Engineering, University of Auckland) ;
  • Sritharan, Sri (Department Civil, Construction, and Environmental Engineering, Iowa State University) ;
  • Ingham, Jason M. (Department Civil and Environmental Engineering, University of Auckland)
  • 투고 : 2015.03.13
  • 심사 : 2015.09.14
  • 발행 : 2016.02.25

초록

To realise the full benefits of a self-centering seismic resilient system, the designer must ensure that the entire structure does indeed re-center following an earthquake. The idealised flag-shaped hysteresis response that is often used to define the cyclic behaviour of self-centering concrete systems seldom exists and the residual drift of a building subjected to an earthquake is dependent on the realistic cyclic hysteresis response as well as the dynamic loading history. Current methods that are used to ensure that re-centering is achieved during the design of self-centering concrete systems are presented, and a series of cyclic analyses are used to demonstrate the flaws in these current procedures, even when idealised hysteresis models were used. Furthermore, results are presented for 350 time-history analyses that were performed to investigate the expected residual drift of an example self-centering concrete wall system during an earthquake. Based upon the results of these time-history analyses it was concluded that due to dynamic shake-down the residual drifts at the conclusion of the ground motion were significantly less than the maximum possible residual drifts that were observed from the cyclic hysteresis response, and were below acceptable residual drift performance limits established for seismic resilient structures. To estimate the effect of the dynamic shakedown, a residual drift ratio was defined that can be implemented during the design process to ensure that residual drift performance targets are achieved for self-centering concrete wall systems.

키워드

과제정보

연구 과제 주관 기관 : NSF

참고문헌

  1. Aaleti, S. and Sritharan, S. (2009), "A simplified analysis method for characterizing unbonded posttensioned precast wall systems", Eng. Struct., 31(12), 2966-2975. https://doi.org/10.1016/j.engstruct.2009.07.024
  2. ACI Innovation Task Group 5 (2007), "Acceptance criteria for special unbonded post-tensioned precast structural walls based on validation testing (ITG 5.1-07)", American Concrete Institute, Farmington Hills, MI.
  3. ACI Innovation Task Group 5 (2009), "Requirements for Design of a Special Unbonded Post-Tensioned Precast Shear Wall Satisfying ACI ITG-5.1 (ITG 5.2-09)", American Concrete Institute, Farmington Hills, MA.
  4. Carr, A. (2003), RUAUMOKO-Inelastic Dynamic Analysis Program, University of Canterbury, Christchurch, New Zealand.
  5. Chou, C.-C. and Hsu, C.-P. (2008), "Hysteretic model development and seismic response of unbonded posttensioned precast CFT segmental bridge columns", Earthq. Eng. Struct. Dyn., 37(6), 919-934. https://doi.org/10.1002/eqe.796
  6. Christopoulos, C., Filiatrault, A. and Folz, B. (2002), "Seismic response of self-centring hysteretic SDOF systems", Earthq. Eng. Struct. Dyn., 31(5), 1131-1150. https://doi.org/10.1002/eqe.152
  7. Christopoulos, C., Pampanin, S. and Priestley, M.J.N. (2003), "Performance-based seismic response of frame structures including residual deformations. Part I: Single-degree of freedom systems", J. Earthq. Eng., 7(1), 97-118. https://doi.org/10.1080/13632460309350443
  8. Cox, K.E. and Ashford, S.A. (2002), "Characterization of large velocity pulses for laboratory testing", PEER 2002/22, Pacific Earthquake Engineering Research Center, Berkeley, CA.
  9. Eatherton, M.R. and Hajjar, J.F. (2011), "Residual drifts of self-centering systems including effects of ambient building resistance", Earthq. Spectra, 27(3), 719-744. https://doi.org/10.1193/1.3605318
  10. Henry, R.S. (2011), "Self-centering precast concrete walls for buildings in regions with low to high seismicity", Ph.D. thesis, University of Auckland, Auckland.
  11. Henry, R.S., Aaleti, S., Sritharan, S. and Ingham, J.M. (2012), "Seismic analysis of a low-damage Precast Wall with End Columns (PreWEC) including interaction with floor diaphragms", J. Struct. Eng. Soc. NZ. (SESOC), 25(1), 69-81.
  12. Kurama, Y.C. (2002), "Hybrid post-tensioned precast concrete walls for use in seismic regions", PCI J., 47(5), 36-59.
  13. Ma, Q.T. (2010), "The mechanics of rocking structures subjected to ground motions", Ph.D. thesis, University of Auckland, New Zealand.
  14. MacRae, G.A. and Kawashima, K. (1997), "Post-earthquake residual displacements of bilinear oscillator", Earthq. Eng. Struct. Dyn., 26(7), 701-716. https://doi.org/10.1002/(SICI)1096-9845(199707)26:7<701::AID-EQE671>3.0.CO;2-I
  15. NZS 3101:2006 Concrete Structures Standard. Wellington, New Zealand, Standards New Zealand: 646.
  16. Palermo, A., Pampanin, S. and Marriott, D. (2007), "Design, modeling, and experimental response of seismic resistant bridge piers with posttensioned dissipating connections", J. Struct. Eng., 133(11), 1648-1661. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:11(1648)
  17. Palmieri, L., Sagan, E., French, C. and Kreger, M. (1997), "Ductile connections for precast concrete frame systems", Mete A. Sozen Symposium, ACI SP 162, American Concrete Institute, Farmington Hills, MI.
  18. Pampanin, S., Marriott, D. and Palermo, A. (2010), PRESSS design handbook, Auckland, New Zealand Concrete Society.
  19. Pennucci, D., Calvi, G.M. and Sullivan, T.J. (2009), "Displacement-based design of precast walls with additional dampers", J. Earthq. Eng., 13(S1), 40-65. https://doi.org/10.1080/13632460902813265
  20. Perez, F. J., R. Sause and L. W. Lu (2003). "Lateral load tests of unbonded post-tensioned precast concrete walls", ACI Special Publication, 211, 161-182.
  21. Priestley, M.J.N., Calvi, G.M. and Kowalsky, M.J. (2007), Displacement-based seismic design of structures, IUSS Press.
  22. Priestley, M.J.N., Sritharan, S., Conley, J.R. and Pampanin, S. (1999), "Preliminary results and conclusions from the PRESSS five-story precast concrete test building", PCI J., 44(6), 42-67. https://doi.org/10.15554/pcij.11011999.42.67
  23. Rahman, M.A. and Sritharan, S. (2006), "An evaluation of force-based design vs. direct displacement-based design of jointed precast post-tensioned wall systems", Earthq. Eng. Eng. Vib., 5(2), 285-296. https://doi.org/10.1007/s11803-006-0620-3
  24. Rahman, M.A. and Sritharan, S. (2007), "Performance-based seismic evaluation of two five-story precast concrete hybrid frame buildings", J. Struct. Eng., 133(11), 1489-1500. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:11(1489)
  25. Restrepo, J.I. and Rahman, A. (2007), "Seismic performance of self-centering structural walls incorporating energy dissipators", J. Struct. Eng., 133(11), 1560-1570. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:11(1560)
  26. Seismology Committee (1999), Recommended lateral force requirements and commentary (Blue book), Structural Engineers Association of California (SEAOC), 327-421.
  27. Sritharan, S., Aaleti, S., Henry, R.S., Liu, K.Y. and Tsai, K.C. (2015), "Precast concrete wall with end columns (PreWEC) for earthquake resistant design", Earthq. Eng. Struct. Dyn., 44(12), 2075-2092. https://doi.org/10.1002/eqe.2576
  28. Stanton, J., Stone, W.C. and Cheok, G.S. (1997), "A hybrid reinforced precast frame for seismic region", PCI J., 42(2), 20-32.
  29. Wight, G.D., Kowalsky, M.J. and Ingham, J.M. (2004), "Shake table testing of post-tensioned concrete masonry walls", RD-04-04, North Carolina State University, Raleigh, NC, USA.

피인용 문헌

  1. Seismic behavior of self-centering reinforced concrete wall enabled by superelastic shape memory alloy bars vol.16, pp.1, 2018, https://doi.org/10.1007/s10518-017-0213-8
  2. Rocking Response Analysis of Self-Centering Walls under Ground Excitations vol.2018, pp.1563-5147, 2018, https://doi.org/10.1155/2018/4371585
  3. Study of Interaction between a PreWEC System and Surrounding Structure vol.115, pp.5, 2018, https://doi.org/10.14359/51702248
  4. Dynamic Evaluation of PreWEC Systems with Varying Hysteretic Energy Dissipation vol.144, pp.10, 2018, https://doi.org/10.1061/(ASCE)ST.1943-541X.0002169
  5. High Performance Damage-Resistant Seismic Resistant Structural Systems for Sustainable and Resilient City: A Review vol.2018, pp.1875-9203, 2018, https://doi.org/10.1155/2018/8703697
  6. ROCKING PERFORMANCE AND ULTIMATE FLEXURAL CAPACITY OF UNBONDED PRECAST POST-TENSIONED WALLS WITH ENERGY DISSIPATING ELEMENTS vol.83, pp.754, 2016, https://doi.org/10.3130/aijs.83.1855
  7. Seismic response analysis of RC frame core-tube building with self-centering braces vol.5, pp.2, 2016, https://doi.org/10.12989/smm.2018.5.2.189
  8. Snap back testing of unbonded post-tensioned concrete wall systems vol.16, pp.2, 2016, https://doi.org/10.12989/eas.2019.16.2.209
  9. Behavior of ductile steel X-braced RC frames in seismic zones vol.18, pp.4, 2016, https://doi.org/10.1007/s11803-019-0539-0
  10. Stochastic Response of SDOF Self-Centering System vol.20, pp.5, 2016, https://doi.org/10.1142/s0219455420500625
  11. Seismic retrofit of a structure using self-centring precast concrete frames with enlarged beam ends vol.72, pp.22, 2016, https://doi.org/10.1680/jmacr.19.00012
  12. Seismic fragility and post-earthquake reparability of circular reinforced concrete bridge columns with low-bond high-strength reinforcements vol.34, pp.None, 2016, https://doi.org/10.1016/j.istruc.2021.08.021
  13. Influence of connection properties on seismic performance of post-tensioned self-centering concrete frames vol.46, pp.None, 2016, https://doi.org/10.1016/j.jobe.2021.103761
  14. Parametric analysis of slotted concrete shear walls reinforced with shape memory alloy bars vol.16, pp.None, 2016, https://doi.org/10.1016/j.cscm.2021.e00806