Acknowledgement
Supported by : Ministry of Education, Culture, Sports, Science and Technology of Japan
References
- ASTM (American Society for Testing Materials) E 519-10. (2010), Standard test method for diagonal tension (shear) in masonry assemblages, Annual Book of ASTM Standards, ASTM International, West Conshohocken PA.
- Araujo, A.S., Oliveira, D.V. and Lourenco, P.B. (2014), "Numerical study on the performance of improved masonry-to-timber connections in traditional masonry buildings", Eng. Struct., 80, 501-513. https://doi.org/10.1016/j.engstruct.2014.09.027
- Benjamin, J.R. (1988), A criterion for determining exceedance of the operating basis earthquake, Report No. EPRI NP-5930, Electrical Power Research Institute, Palo Alto, California, USA.
- British Standards Institution (1999), BS EN 1052-1:1999, Methods of test for masonry-Part 1: Determination of compressive strength, BSI, London, UK.
- British Standards Institution (2002), BS EN 1052-3:2002, Methods of test for masonry-part 3: determination of initial shear strength, BSI, London, UK.
- International Conference of Building Officials (ICBO) (1997), Uniform Building Code, ICBO, Whittier, CA, USA.
- Lourenco, P.B., Mendes, N., Ramos, L.F. and Oliveira, D.V. (2011), "Analysis of masonry structures without box behavior", Int. J. Architec. Herit.: Conserv., Anal. Rest., 5(4-5), 369-382. https://doi.org/10.1080/15583058.2010.528824
- Magenes, G., Penna, A., Senaldi, I.E., Galasco, A. and Rota, M. (2013), "Experimental investigation on the effect of diaphragm in-plane stiffness on the seismic response of masonry buildings", 12th Canadian Masonry Symposium, Vancouver B.C., Canada.
- Magenes. G., Penna, A., Senaldi, I.E., Rota, M. and Galasco, A. (2014), "Shaking table test of a strengthened full scale stone masonry building with flexible diaphragms", Int. J. Architec. Herit., 8(3), 349-375. https://doi.org/10.1080/15583058.2013.826299
- Rota, M., Penna, A., Strobbia, C. and Magenes, G. (2011), "Typological seismic risk maps for Italy", Earthq. Spectra, 27(3), 907-926. https://doi.org/10.1193/1.3609850
- Sathiparan, N., Mayorca, P., Nesheli, N., Ramesh, G. and Meguro, K. (2005), "In-Plane and Out-of-Plane behavior of PP-band retrofitted masonry wallettes",4th International Symposium on New Technologies for Urban Safety of Mega Cities in Asia, Nanyang Technological University, Singapore.
- Sathiparan, N., Mayorca, P. and Meguro, K. (2012), "Shaking table test on one-quarter scale models of masonry houses retrofitted with PP-band mesh", Earthq. Spectra, 28(1), 277-299. https://doi.org/10.1193/1.3675357
- Sathiparan, N. and Meguro, K. (2012), "Seismic behavior of low earthquake-resistant arch-shaped roof masonry houses retrofitted by PP-band meshes", Practice Period. Struct. Des. Constr., 17(2), 54-64. https://doi.org/10.1061/(ASCE)SC.1943-5576.0000113
- Senaldi, I., Magenes, G., Penna, A., Galasco, A. and Rota, M. (2013), "The effect of stiffened floor and roof diaphragms on the experimental seismic response of a full scale unreinforced stone masonry building", J. Earthq. Eng., 18(3), 407-443. https://doi.org/10.1080/13632469.2013.876946
- Simsir C.C., Aschheim, M.A. and Abrams, D.P. (2004), "Out-of-plane dynamic response of unreinforced masonry bearing walls attached to flexible diaphragms", 13th World Conference on Earthquake Engineering, Vancouver B.C., Canada.
- Tomazevic, M., Velechovsky, T. and Weiss, P. (1992), "The effect of interventions in the floor structural system on the seismic resistance of historic stone-masonry buildings: An experimental study", 10th World Conference on Earthquake Engineering, Madrid, Spain.
Cited by
- Role of diaphragm flexibility modelling in seismic analysis of existing masonry structures vol.11, 2017, https://doi.org/10.1016/j.istruc.2017.04.001
- Classification and seismic fragility assessment of confined masonry school buildings vol.19, pp.5, 2016, https://doi.org/10.1007/s10518-021-01061-9