DOI QR코드

DOI QR Code

공공하수처리시설에서 수질오염물질 유입 및 배출 특성 고찰 - 산업폐수 및 매립지 침출수 연계처리 시설을 중심으로 -

A study on characteristics of influent and effluent pollutants in public sewage treatment works combined with industrial wastewater and landfill leachate

  • 정동환 (국립환경과학원 상하수도연구과) ;
  • 조양석 (국립환경과학원 상하수도연구과) ;
  • 안경희 (국립환경과학원 상하수도연구과) ;
  • 김은석 (국립환경과학원 상하수도연구과) ;
  • 김창수 (국립환경과학원 상하수도연구과) ;
  • 정현미 (국립환경과학원 상하수도연구과)
  • 투고 : 2016.08.03
  • 심사 : 2016.10.30
  • 발행 : 2016.12.23

초록

In this study, we investigated influent and effluent water pollutants in 53 Public Sewage Treatment Works (PSTWs) where industrial wastewater or landfill leachate is combined four times for two years from 2014 to 2015. Also, we analyzed the characteristics of heavy metals and volatile organic carbons at influent and effluent of these PSTWs caused by sewage treatment combined with industrial wastewater or landfill leachate. As a result, six heavy metals such as barium, copper, iron, manganese, nickel and zinc, and four volatile organic carbons (VOCs) including phenols, di(2-)ethylhexyl phthalate (DEHP), formaldehyde and toluene were observed above detection limits in most of PSTWs. Also, it was revealed that six heavy metals such as hexavalent chromium, mercury, cadmium, chromium, nickel and selenium, and four VOCs including 1,1-dichloroethylene, vinyl chloride, naphthalene, and epichlorohydrin were observed more frequently according to precipitation. As a result of reviewing the monitoring data on "Water Quality Monitoring Networks" in lower watersheds of PSTWs, both heavy metals and VOCs were below detection limits, indicating that the effluent water had little influence on the watershed. Nevertheless for the better management of influent and effluent pollutants in PSTWs, it is necessary to establish the advanced management plans for water pollutants in PSTWs, which include a list of priority substances management, monitoring plans, and guidelines for industrial wastewater and landfill leachate combined in PSTWs.

키워드

참고문헌

  1. European Commission of Environment(EC) (2003) Achievements and obstacles in the implementation of council directive 76/464/EEC on aquatic pollution control of dangerous substances(1976-2002).
  2. European Union(EU) (2013) Directive 2013/39/EU of the european parliament and of the council of 12 August 2013 amending Directive 2000/60/EC and 2008/105/EC as regards priority substances in the field of water policy.
  3. Federal Ministry for the Environment, Nature Conservation and Nuclear Safety(FMENCN) (2004) Promulgation of the new version of the ordinance on requirements for the discharge of wastewater into waters.
  4. Ministry of Environment(MOE) (2011) Guideline for industrial wastewater co-treated public sewage treatment works.
  5. Ministry of Environment (2014a) Guideline for operation and management of public sewage system.
  6. Ministry of Environment (2014b) http://hasudoinfo.or.kr (Integrated information management system for sewer system).
  7. Ministry of Environment (2016) The raw for water quality and water ecosystem preservation.
  8. National Institute of Environmental Research(NIER) (2011) A study on appropriate treatment and management of the public sewage treatment works receiving the industrial wastewater.
  9. Reglement de Service D'assainissement(RSD) (2012) Syndicat D'agglomeration Nouvelle de Marne-la-Vallee, Val Maubuee, France.
  10. US EPA (2010) National Pollutant Discharge Elimination System(NPDES) permit writers' manual.

피인용 문헌

  1. 하수처리장에서의 연계처리수 요금 개선에 따른 경제성 분석 vol.22, pp.2, 2016, https://doi.org/10.17663/jwr.2020.22.2.139
  2. 하수처리 모델링을 이용한 연계처리 시나리오별 운전조건 최적화 vol.23, pp.1, 2016, https://doi.org/10.17663/jwr.2021.23.1.7