Acknowledgement
Supported by : Australian Research Council
References
- AAMA 501.4 (2009), Recommended Static Testing Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Interstory Drift: Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from a Wall System, American Architectural Manufacturers Association,USA.
- Aldemir, U. (2003), "Optimal control of structures with semiactive-tuned mass dampers", J. Sound Vib., 266(4), 847-874. https://doi.org/10.1016/S0022-460X(03)00191-3
- AS1170.4 (2007), Structural design actions Part 4: Earthquake actions in Australia, Australian/New Zealand Standard, Australia.
- Baird, A., Diaferia, R., Palermo, A. and Pampanin, S. (2011), "Parametric investigation of seismic interaction between precast concrete cladding systems and moment resisting frames", ASCE Structures Congress, Las Vegas, USA, April.
- Behr, R.A. (1998), "Seismic performance of architectural glass in mid-rise curtain wall", J. Architec. Eng., 4(3), 94-98. https://doi.org/10.1061/(ASCE)1076-0431(1998)4:3(94)
- Behr, R.A. and Belarbi, A. (1996), "Seismic test methods for architectural glazing systems", Earthq. Spectra, 12(1), 129-143. https://doi.org/10.1193/1.1585871
- Bupp, R.T., Bernstein, D.S., Chellaboina, V.S. and Haddad, W.M., (2000), "Resetting virtual absorbers for vibration control", J. Vib. Control, 6(1), 61-83. https://doi.org/10.1177/107754630000600104
- Hareer, R.W. (2007), "Seismic response of building facade with energy absorbing connections", Ph.D. Dissertation, Queensland University of Technology, Brisbane, Australia.
- De Matteis, G. (2005), "Effect of lightweight cladding panels on the seismic performance of moment resisting steel frames", Eng. Struct., 27(11), 1662-1676. https://doi.org/10.1016/j.engstruct.2005.06.004
- Fu, T.S. and Johnson, E.A. (2013), "Active control for a distributed mass damper system", J. Eng. Mech., 140(2), 426-429.
- Fu, T.S. and Johnson, E.A. (2010), "Distributed mass damper system for integrating structural and environmental controls in buildings", J. Eng. Mech., 137(3), 205-213.
- Goodno, B.J., Pinelli, J.P and Craig, J.I. (1996), "An Optimal design approach for passive damping of building structures using architectural Cladding", Proceeding of the Eleventh World Conference on Earthquake Engineering, Acapulco, Mexico, June.
- Hunt, J.P. (2010), "Seismic performance assessment and probabilistic repair cost analysis of precast concrete cladding systems for multistory buildings", Ph.D. Dissertation, University of California, Berkeley, USA.
- Ji, H.R., Moon, Y.J., Kim, C.H. and Lee, I.W. (2005), "Structural vibration control using semiactive tuned mass damper", The eighteenth KKCNN Symposium on Civil Engineering-KAIST6, Taiwan, December.
- Li, B., Hutchinson, G.L. and Duffield, C.F. (2011), "The influence of non‐structural components on tall building stiffness", Struct. Des. Tall Spec. Build., 20(7), 853-870. https://doi.org/10.1002/tal.565
- Li, C. and Lio, Y, (2002), "Further characteristics for multiple tuned mass dampers", J. Struct. Eng., 128(10), 1362-1365. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:10(1362)
- Maneetes, H. and Memari, A.M. (2014), "Introduction of an innovative cladding panel system for multistory buildings", Buildings, 4(3), 418-436. https://doi.org/10.3390/buildings4030418
- Moon, K. (2009), "Tall building motion control using double skin façades", J. Architec. Eng., 15(3), 84-90. https://doi.org/10.1061/(ASCE)1076-0431(2009)15:3(84)
- Pinelli, J.P., Craig, J.I. and Goodno, B.J. (1995), "Energy-based seismic design of ductile cladding systems", J. Struct. Eng., 121(3), 567-578. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:3(567)
- Thambiratnam, D. (2010), "Seismic mitigation of building structural systems using passive dampers", Proreeding of the 9th US National and 10th Canadian Conference on Earthquake Engineering, Torento, December.
- Yankelevsky, D.Z., Schwarz, S. and Karinski, Y. (2011), "Theory and practice in reducing the vulnerability of residential buildings subjected to extreme loads-a multi hazard perspective", Appl. Mech. Mater.,82(2), 3-14. https://doi.org/10.4028/www.scientific.net/AMM.82.3