DOI QR코드

DOI QR Code

Delayed-Onset Methicillin-Resistant Staphylococcus aureus Infection at 18 Months after Absorbable Plate Fixation for Zygomaticomaxillary Complex Fracture

  • Lee, Hyun Rok (Department of Plastic and Reconstructive Surgery, Dongguk University College of Medicine) ;
  • Shin, Hea Kyeong (Department of Plastic and Reconstructive Surgery, Dongguk University College of Medicine) ;
  • Lee, Dong Lark (Department of Plastic and Reconstructive Surgery, Dongguk University College of Medicine) ;
  • Jung, Gyu Yong (Department of Plastic and Reconstructive Surgery, Dongguk University College of Medicine)
  • Received : 2016.04.13
  • Accepted : 2016.08.10
  • Published : 2016.12.20

Abstract

None of the reports of delayed infection mentioned a latent period exceeding 13 months. we report an infection that developed 18 months after implantation of an absorbable plate. A 16-year-old adolescent girl had undergone reduction and fixation with an absorbable plate for Lefort I and zygomaticomaxillary complex fractures 18 months prior at our hospital. In her most recent hospital visit as an outpatient, abscess was observed in periocular area. Computed tomography revealed sinusitis with an abscess above the infraorbital rim. Wound culture yielded methicillin-resistant Staphylococcus aureus. Despite conservative treatments, wound state did not improve. Therefore, our department decided to perform surgery. Absorbable plate had been mostly absorbed but remained a bit. Bony depression of infraorbital rim and mucosal exposure of maxillary sinus anterior wall were observed. After the surgery, the patient recovered. We believe that the reason the wound infection and sinusitis manifested at the same time is because of several factor such as alcohol abuse, smoking, and mucosal exposure of maxillary sinus anterior wall. Absorbable plate takes 9 months to 3 years to be completely absorbed, thus we suggest studies with a follow-up of at least 3 years be undertaken to determine the outcomes of patients with many risk factors.

Keywords

References

  1. Wittwer G, Adeyemo WL, Yerit K, Voracek M, Turhani D, Watzinger F, et al. Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis? Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2006;101:419-25. https://doi.org/10.1016/j.tripleo.2005.07.026
  2. Kwon H, Kim SW, Jung SN, Sohn WI, Moon SH. Cellulitis related to bioabsorbable plate and screws in infraorbital rim fracture. J Craniofac Surg 2011;22:625-7. https://doi.org/10.1097/SCS.0b013e3182085541
  3. Lee JH, Chang JW, Choi MS, Ahn HC. Delayed infection after a zygoma fracture fixation with absorbable plates. J Craniofac Surg 2010;21:2018-9. https://doi.org/10.1097/SCS.0b013e3181f5387c
  4. Tuncer S, Yavuzer R, Kandal S, Demir YH, Ozmen S, Latifoglu O, et al. Reconstruction of traumatic orbital floor fractures with resorbable mesh plate. J Craniofac Surg 2007;18:598-605. https://doi.org/10.1097/01.scs.0000246735.92095.ef
  5. Hollier LH, Rogers N, Berzin E, Stal S. Resorbable mesh in the treatment of orbital floor fractures. J Craniofac Surg 2001;12:242-6. https://doi.org/10.1097/00001665-200105000-00009
  6. Elek SD, Conen PE. The virulence of Staphylococcus pyogenes for man; a study of the problems of wound infection. Br J Exp Pathol 1957;38:573-86.
  7. Ashammakhi N, Peltoniemi H, Waris E, Suuronen R, Serlo W, Kellomaki M, et al. Developments in craniomaxillofacial surgery: use of self-reinforced bioabsorbable osteofixation devices. Plast Reconstr Surg 2001;108:167-80. https://doi.org/10.1097/00006534-200107000-00027
  8. Park CH, Kim HS, Lee JH, Hong SM, Ko YG, Lee OJ. Resorbable skeletal fixation systems for treating maxillofacial bone fractures. Arch Otolaryngol Head Neck Surg 2011;137:125-9. https://doi.org/10.1001/archoto.2010.241
  9. Choi HJ, Kim W, Youn S, Lee JH. Management of delayed infection after insertion of bioresorbable plates at the infraorbital rim. J Craniofac Surg 2012;23:524-5. https://doi.org/10.1097/SCS.0b013e31824cd4de