DOI QR코드

DOI QR Code

Effect of Wall Thickness on Thermal Behaviors of RC Walls Under Fire Conditions

  • Kang, Jiyeon (Department of Architectural Engineering, Ewha Womans University) ;
  • Yoon, Hyunah (Department of Architectural Engineering, Ewha Womans University) ;
  • Kim, Woosuk (School of Architecture, Kumoh National Institute of Technology) ;
  • Kodur, Venkatesh (Department of Civil and Environmental Engineering, Michigan State University) ;
  • Shin, Yeongsoo (Department of Architectural Engineering, Ewha Womans University) ;
  • Kim, Heesun (Department of Architectural Engineering, Ewha Womans University)
  • 투고 : 2016.03.22
  • 심사 : 2016.07.11
  • 발행 : 2016.09.30

초록

The objective of this paper is to investigate the effect of thickness and moisture on temperature distributions of reinforced concrete walls under fire conditions. Toward this goal, the first three wall specimens having different thicknesses are heated for 2 h according to ISO standard heating curve and the temperature distribution through the wall thickness is measured. Since the thermal behavior of the tested walls is influenced by thickness, as well as moisture content, three additional walls are prepared and preheated to reduce moisture content and then tested under fire exposure. The experimental results clearly show the temperatures measured close to the fire exposed surface of the thickest wall with 250 mm thickness is the highest in the temperatures measured at the same location of the thinner wall with 150 mm thickness because of the moisture clog that is formed inside the wall with 250 mm of thickness. This prevents heat being transferred to the opposite side of the heated surface. This is also confirmed by the thermal behavior of the preheated walls, showing that the temperature is well distributed in the preheated walls as compared to that in non-preheated walls. Finite element models including moisture clog zone are generated to simulate fire tests with consideration of moisture clog effect. The temperature distributions of the models predicted from the transient heat analyses are compared with experimental results and show good agreements. In addition, parametric studies are performed with various moisture contents in order to investigate effect of moisture contents on the thermal behaviors of the concrete walls.

키워드

참고문헌

  1. ABAQUS. (2010). Theory manual version 6.10-3. Providence, RI: Dassault Systemes Simulia Corp.
  2. ACI committee 318-11. (2011). Building code requirements for structural concrete (ACI 318-11). Farmington Hills, MI: American Concrete Institute.
  3. Bazant, Z. P., & Thonguthai, W. (1979). Pore pressure in heated concrete walls: theoretical prediction. Magazine of Concrete Research, 31(107), 67-76. https://doi.org/10.1680/macr.1979.31.107.67
  4. Beyea, S. D., Balcom, B. J., Bremner, T. W., Prado, P. J., Green, D. P., Armstrong, R. L., & Grattan-Bellew, P. E. (1998). Magnetic resonance imaging and moisture content profiles of drying concrete. Cement and Concrete Research, 28(3), 453-463. https://doi.org/10.1016/S0008-8846(98)00009-X
  5. Choi, J., Haj-Ali, R., & Kim, H. (2012). Integrated fire dynamic and thermomechanical modeling of a bridge under fire. Structural Engineering and Mechanics, 42(6), 815-829. https://doi.org/10.12989/sem.2012.42.6.815
  6. Consolazio, G. R., McVay, M. C., Rish, I. I. I., & J. W., (1998). Measurement and prediction of pore pressures in saturated cement mortar subjected to radiant heating. ACI Structural Journal, 95(5), 525-536.
  7. Crozier, D. A., & Sanjayan, J. G. (2000). Test of load-bearing slender reinforced concrete walls in fire. ACI Structural Journal, 97(2), 243-253.
  8. Dwaikat, M. B., & Kodur, V. K. R. (2009). Hydrothermal model for predicting fire-induced spalling in concrete structural systems. Fire Safety Journal, 44(3), 425-434. https://doi.org/10.1016/j.firesaf.2008.09.001
  9. Eurocode 2. (2006). Design of concrete structure-part 1-2: General rules-structural fire design. BS EN 1992-1-2:2006.
  10. Hamarthy, T. A. (1965). Effect of moisture on the fire endurance of building elements. West Conshohocken, PA: ASTM Publication STP 385, American Society of Testing and Materials.
  11. ISO 834-2012. (2012). ISO fire resistance test-elements of building construction, International Organization of Standardization, Geneva, Switzerland.
  12. Jansson, R. (2004). Measurement of thermal properties at elevated temperatures-Brandforsk project 328-031, SP Swedish National Testing and Research Institute.
  13. KCI design recommendations. (2012). Concrete design code and commentary. Seoul, Korea: Korea Concrete Institute. (in Korean)
  14. Khoylou, N. (1997). Modeling of moisture migration and spalling behavior in non-uniformly heated concrete, Ph.D. Thesis, Imperial College, UK.
  15. Ko, J. W., Ryu, D. W., Lee, M. H., & Lee, S. H. (2007). Study on the behavior of microstructure and spalling mechanism by heat and moisture movement in concrete under fire environment. Journal of the Architectural Institute of Korea Structure & Construction, 23(12), 107-116. (in Korean)
  16. Kodur, V. K. R. (2014). Properties of concrete at elevated temperatures, ISRN Civil engineering.
  17. Kodur, V. K. R., Dwaikat, M. M. S., & Dwaikat, M. B. (2008). High-temperature properties of concrete for fire resistance modeling of structures. ACI Materials Journal, 105(5), 517-527.
  18. Kodur, V. K. R., & Phan, L. (2007). Critical factors governing the fire performance of high strength concrete systems. Fire Safety Journal, 42(6), 482-488. https://doi.org/10.1016/j.firesaf.2006.10.006
  19. Lee, T.-G. (2009). Prediction of moisture migration of concrete including internal vaporization in fire. Journal of Korean Institute of Fire Science & Engineering, 13(5), 17-23.
  20. Lee, S., & Lee, C. (2013). Fire resistance of reinforced concrete bearing walls subjected to all-sided fire exposure. Materials and Structures, 46(6), 943-957. https://doi.org/10.1617/s11527-012-9945-8
  21. Ngo, T., Fragomeni, S., Mendis, P., & Ta, B. (2013). Testing of normal- and high- strength concrete walls subjected to both standard and hydrocarbon fires. ACI Structural Journal, 110(3), 503-510.
  22. NIST. (1997). Spalling phenomena of HPC and OC.
  23. O'Meagher, A. J., & Bennetts, I. D. (1991). Modeling of concrete walls in fire. Fire Safety Journal, 17(4), 315-335. https://doi.org/10.1016/0379-7112(91)90026-U
  24. Regulation for refuge and prevention of fire in building, Korea ministry of land, infrastructure and transport, 2015. (in Korean)
  25. Schneider, U. (1982). Behaviour of concrete at high temperatures, German committee for reinforced concrete (pp. 1-122). Berlin, Germany: Heft 377, Verlag, W. Ernst and Sohn.
  26. Selih, J., Sousa, A. C. M., & Bremner, T. W. (1994). Moisture and heat flow in concrete walls exposed to fire. ASCE Journal of Engineering Mechanics, 120(10), 2028-2043. https://doi.org/10.1061/(ASCE)0733-9399(1994)120:10(2028)
  27. Szoke, S. S. (2006). Resistance to fire and high temperature (pp. 274-287). Arlington, VA: Portland Cement Association, Research & Development Information.

피인용 문헌

  1. Seismic Capacity Design and Retrofit of Reinforced Concrete Staggered Wall Structures vol.11, pp.2, 2016, https://doi.org/10.1007/s40069-017-0192-9
  2. 폭발 후 화재하중 시나리오에 따른 2방향 프리스트레스트 콘크리트 패널부재의 손상도 평가 vol.29, pp.3, 2016, https://doi.org/10.4334/jkci.2017.29.3.237
  3. Behavior of High-Strength Polypropylene Fiber-Reinforced Self-Compacting Concrete Exposed to High Temperatures vol.30, pp.11, 2016, https://doi.org/10.1061/(asce)mt.1943-5533.0002491
  4. Briefing: Non-destructive evaluation and contrasts of concrete overheated and abruptly cooled vol.171, pp.6, 2016, https://doi.org/10.1680/jstbu.17.00027
  5. An experimental study for the thermal behavior of composite concrete beam with slab compared with isolated beam under fire vol.431, pp.None, 2016, https://doi.org/10.1088/1757-899x/431/11/112004
  6. Effect of Mixture Ratios on Thermal Behaviours of High Strength Concrete Walls Exposed to Fire on Foreside vol.431, pp.None, 2018, https://doi.org/10.1088/1757-899x/431/4/042010
  7. Effect of Loading and Beam Sizes on the Structural Behaviors of Reinforced Concrete Beams Under and After Fire vol.12, pp.1, 2016, https://doi.org/10.1186/s40069-018-0280-5
  8. Fire Resistance Investigation of Simple Supported RC Beams with Varying Reinforcement Configurations vol.2019, pp.None, 2016, https://doi.org/10.1155/2019/8625360
  9. Analytical studies for the effect of thickness and axial load on load bearing capacity of fire damaged concrete walls with different sizes vol.4, pp.2, 2019, https://doi.org/10.1080/24705314.2019.1603189
  10. Experimental investigation on the compressive strength of PFGP-covered concretes exposed to high temperature vol.10, pp.4, 2016, https://doi.org/10.1108/jsfe-11-2018-0033
  11. A review on research of fire-induced progressive collapse on structures vol.12, pp.3, 2016, https://doi.org/10.1108/jsfe-07-2020-0023
  12. Fire resistance of bi-directionally prestressed concrete under extreme fire loading vol.174, pp.9, 2016, https://doi.org/10.1680/jstbu.20.00075