DOI QR코드

DOI QR Code

Trend of Fire Outbreaks in Ghana and Ways to Prevent These Incidents

  • Addai, Emmanuel K. (Department of Plant Design and Process Safety, University of Magdeburg) ;
  • Tulashie, Samuel K. (Department of Chemistry, Industrial Chemistry Unit, University of Cape Coast) ;
  • Annan, Joe-Steve (Sekondi Palm Lands) ;
  • Yeboah, Isaac (Department of Chemical Engineering, Norwegian University of Science and Technology (NTNU))
  • Received : 2015.10.06
  • Accepted : 2016.02.16
  • Published : 2016.12.30

Abstract

Background: In Ghana, fire incidents have become a regular occurrence, with thousands of lives and millions of dollars lost every year. Hardly a day passes without news of a fire outbreak in some part of Ghana, causing fear and panic among the people. This generates much discussion centering on rumors relating to politics, sabotage, misfortune, religious differences, etc. This article seeks to discuss the trend of fire incidents occurring in Ghana from 2000 to 2013 and the different ways to prevent these incidents. Methods: The pattern of fire incidence in Ghana as a whole as well as in each region is discussed. The study took into consideration the causes, mechanisms, as well as preventive measures against the fire menace. Data were obtained from the head office of Ghana's national fire service. Results: It was noticed that in general the rate of fire incidence increased each year. This increase was attributed to several factors: rate of population growth and industrialization, unstable electricity, urbanization, negligence, illegal electrical connection, etc. The cause of fire was categorized into domestic, industrial, vehicular, institutional, electrical, commercial, bush, and others. Among these causes, domestic fire accounted for 41% of the total number of fire incidents in the country. Conclusion: Finally, this study presents several recommendations to help prevent and mitigate fire incidents in Ghana.

Keywords

References

  1. Barnett JR. Fire. Microsoft Student 2009 (DVD). Redmond (WA): Microsoft Corporation; 2008.
  2. Ayarkwa J, Danso AK, Adinyira E. Incidence of domestic fire outbreaks in Ghana: causes and prevention. Ghana Surveyor 2010;4:1-13.
  3. Occupational Safety and Health Administration, U.S. Department of Labor. Combustible dust [Internet]. 2016 [cited 2016 Mar 14]. Available from: https://www.osha.gov/dsg/combustibledust/index.html.
  4. Addai EK, Gabel D, Krause U. Lower explosion limit of hybrid mixtures of burnable gas and dust. J Loss Prevent Process Ind 2015;36:497-504. https://doi.org/10.1016/j.jlp.2015.02.014
  5. Addai EK, Gabel D, Krause U. Explosion characteristics of three component hybrid mixtures. Process Saf Environ Protect 2015;9:72-81.
  6. Addai EK, Gabel D, Krause U. Experimental investigation on the minimum ignition temperature of hybrid mixtures of dusts and gases or solvents. J Hazard Mater 2016;301:314-26. https://doi.org/10.1016/j.jhazmat.2015.09.006
  7. Nolan DP. Handbook of fire and explosion protection engineering principles. 3rd ed. Kidlington (UK): William Andrew; 2014. 496 p.
  8. Swetnam TW. Fire history and climate change in giant sequoia groves. Science 1993;262:885-9. https://doi.org/10.1126/science.262.5135.885
  9. Sam-Okyere E. Infernos in our offices; demystifying the facts. The Chronicle. 2010 Feb 25; p. 3.
  10. Gakpe BK, Mahama PY. Reportage of stories on fire outbreaks in Ghana: an analysis of the Daily Graphic and the Chronicle. New Media Mass Commun 2014;24:1-11.
  11. Ghana National Fire Service Ghana National Fire Service Act, 1997 [Internet]. 2014 [cited 2014 Jan 6]. Available from: http://www.epa.gov.gh/ghanalex/acts/Acts/GHANA%20NATIONAL%20FIRE%20SERVICE%20ACT,1997.pdf.
  12. Annan J-S, Addai EK, Tulashie SK. A call for action to improve occupational health and safety in Ghana and a critical look at the existing legal requirement and legislation. Saf Health Work 2015;6:146-50. https://doi.org/10.1016/j.shaw.2014.12.002
  13. Tulashie SK, Addai EK, Annan J-S. Exposure assessment, a preventive process in managing workplace safety and health, challenges in Ghana. Saf Sci 2016;84:210-5. https://doi.org/10.1016/j.ssci.2015.12.023
  14. Simpson DE. Fire protection and safety. A presentation of Ghana National Fire Service (GNFS). Ashanti Regional office at a Symposium of Building Technology Students Society (BTSS) Week celebration, Kwame Nkrumah University of Science and Technology (KNUST), Kumasi, 24-27 March 2010.
  15. Anaglatey PB. Accra continues to record fire outbreaks. The Chronicle. 2013 Jul 30.
  16. Boateng W. Electricity company of Ghana explains causes of fire outbreaks. Ghanaian Times. 2013 Jan 24.
  17. Abu J. Smoking is number one cause of fire outbreak in Ghana. Ghana News Agency. 2013 March 18.
  18. Madrzykowski D. Fire dynamics: the science of fire fighting. Int Fire Service J Leadership Manage 2013;7:7-15.
  19. Twum-Barima LM. An assessment of the awareness of fire insurance in the informal sector: a case study of Kumasi central market in Ghana. Int J Hum Soc Sci Educ (IJHSSE) 2014;1:41-7.
  20. Owusu-Ansah D. Population distribution. In: La Verle B, editor. A country study: Ghana. Library of Congress Federal Research Division; November 1994 [This article incorporates text from this source, which is in the public domain.].
  21. Ghana Statistical Service. 2010 Population & housing census. Summary report of final results [Internet]. Accra (Ghana): Ghana Statistical Service; 2012. Available from: http://www.statsghana.gov.gh/docfiles/2010phc/Census2010_Summary_report_of_final_results.pdf.
  22. Sarpong AO. Fire risk vulnerability in informal settlements the case of Ashaiman. MS thesis. Accra (Ghana): University of Ghana; 2013.
  23. Asian Disaster Preparedness Center (ADPC). Reducing fire threat to homes: piloting community-based fire risk assessment in Ban Hatsady Village. Safer Cities 2004;9.
  24. Lamm W. Hydrant color codes and markings [Internet]. 2000 [cited 2015 Mar 31]. Available from: http://www.firehydrant.org/info/design07.html.

Cited by

  1. Repair of The Bracket and Clutch Mechanism On Centrifugal Pump For Firefighter Motorcycle vol.218, pp.None, 2016, https://doi.org/10.1051/matecconf/201821804009
  2. Experimental study of thermal radiation from jet flame vol.105, pp.None, 2016, https://doi.org/10.1088/1755-1315/105/1/012085
  3. Assessing Social Vulnerability to Fire Hazards at the Kumasi Central Market, Ghana : vol.9, pp.4, 2016, https://doi.org/10.4018/ijagr.2018100104
  4. Technical, human, and organizational factors affecting failures of firefighting systems (FSs) of atmospheric storage tanks: Providing a risk assessment approach using Fuzzy Bayesian Network (FBN) and vol.65, pp.None, 2016, https://doi.org/10.1016/j.jlp.2020.104157
  5. Adoption Determinants of Agricultural Extension Communication Channels in Emergency and Non-emergency Situations in Ghana vol.7, pp.1, 2016, https://doi.org/10.1080/23311932.2021.1872193
  6. Impacts of Electricity Outages in Urban Households in Developing Countries: A Case of Accra, Ghana vol.14, pp.12, 2016, https://doi.org/10.3390/en14123676
  7. Business continuity and disaster recovery in Ghana-a literature review vol.3, pp.2, 2021, https://doi.org/10.1108/crr-03-2021-0006
  8. PRIORITIZATION OF FOREST FIRE HAZARD RISK SIMULATION USING HYBRID GREY RELATIVITY ANALYSIS (HGRA) AND FUZZY ANALYTICAL HIERARCHY PROCESS (FAHP) COUPLED WITH MULTICRITERIA DECISION ANALYSIS (MCDA) TECH vol.47, pp.3, 2021, https://doi.org/10.3846/gac.2021.13028
  9. Africa: Taking fire safety forwards vol.45, pp.8, 2016, https://doi.org/10.1002/fam.2894