참고문헌
- Kim SJ, Yoo J, Kim YS, Shin SW. Temperature change in pig rib bone during implant site preparation by low-speed drilling. J Appl Oral Sci 2010;18:522-7. https://doi.org/10.1590/S1678-77572010000500016
- Giro G, Marin C, Granato R, Bonfante EA, Suzuki M, Janal MN, et al. Effect of drilling technique on the early integration of plateau root form endosteal implants: an experimental study in dogs. J Oral Maxillofac Surg 2011;69:2158-63. https://doi.org/10.1016/j.joms.2011.01.029
- Gaspar J, Borrecho G, Oliveira P, Salvado F, Martins dos Santos J. Osteotomy at low-speed drilling without irrigation versus highspeed drilling with irrigation: an experimental study. Acta Med Port 2013;26:231-6.
- Misir AF, Sumer M, Yenisey M, Ergioglu E. Effect of surgical drill guide on heat generated from implant drilling. J Oral Maxillofac Surg 2009;67:2663-8. https://doi.org/10.1016/j.joms.2009.07.056
- Jeong SM, Yoo JH, Fang Y, Choi BH, Son JS, Oh JH. The effect of guided flapless implant procedure on heat generation from implant drilling. J Craniomaxillofac Surg 2014;42:725-9. https://doi.org/10.1016/j.jcms.2013.11.002
- Anitua E, Carda C, Andia I. A novel drilling procedure and subsequent bone autograft preparation: a technical note. Int J Oral Maxillofac Implants 2007;22:138-45.
- Eriksson RA, Albrektsson T. The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber. J Oral Maxillofac Surg 1984;42:705-11. https://doi.org/10.1016/0278-2391(84)90417-8
- Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 1986;44:4-7. https://doi.org/10.1016/0278-2391(86)90006-6
- Harris BH, Kohles SS. Effects of mechanical and thermal fatigue on dental drill performance. Int J Oral Maxillofac Implants 2001;16:819-26.
- Chacon GE, Bower DL, Larsen PE, McGlumphy EA, Beck FM. Heat production by 3 implant drill systems after repeated drilling and sterilization. J Oral Maxillofac Surg 2006;64:265-9. https://doi.org/10.1016/j.joms.2005.10.011
- Sharawy M, Misch CE, Weller N, Tehemar S. Heat generation during implant drilling: the significance of motor speed. J Oral Maxillofac Surg 2002;60:1160-9. https://doi.org/10.1053/joms.2002.34992
- Carvalho AC, Queiroz TP, Okamoto R, Margonar R, Garcia IR Jr, Magro Filho O. Evaluation of bone heating, immediate bone cell viability, and wear of high-resistance drills after the creation of implant osteotomies in rabbit tibias. Int J Oral Maxillofac Implants 2011;26:1193-201.
피인용 문헌
- Effect of pre-drilling on intraosseous temperature during self-drilling mini-implant placement in a porcine mandible model vol.59, pp.1, 2016, https://doi.org/10.2334/josnusd.16-0316
- The Influence of Thrust Force on the Vitality of Bone Chips Harvested for Autologous Augmentation during Dental Implantation vol.12, pp.22, 2016, https://doi.org/10.3390/ma12223695
- 폭이 좁은 치조골에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 식립한 narrow implant의 방사선학적 평가 vol.58, pp.4, 2016, https://doi.org/10.4047/jkap.2020.58.4.306
- Effect of Surgical Instrumentation Variables on the Osseointegration of Narrow- and Wide-Diameter Short Implants vol.79, pp.2, 2016, https://doi.org/10.1016/j.joms.2020.09.041
- The Assessment of the Maximum Heat Production and Cooling Effectiveness of Three Different Drill Types (Conical vs. Cylindrical vs. Horizontal) during Implant Bed Preparation-An In Vitro Study vol.11, pp.21, 2016, https://doi.org/10.3390/app11219961