DOI QR코드

DOI QR Code

Numerical evaluation of FRP composite retrofitted reinforced concrete wall subjected to blast load

  • Nam, Jin-Won (Baytech Korea Inc.) ;
  • Yoon, In-Seok (Department of Construction Information Engineering, Induk University) ;
  • Yi, Seong-Tae (Department of Civil & Environmental Engineering, Inha College)
  • Received : 2015.10.05
  • Accepted : 2015.12.10
  • Published : 2016.02.25

Abstract

High performance materials such as Fiber Reinforced Plastic (FRP) are often used for retrofitting structures against blast loads due to its ductility and strength. The effectiveness of retrofit materials needs to be precisely evaluated for the retrofitting design based on the dynamic material responses under blast loads. In this study, the blast resistance of Carbon Fiber Reinforced Plastic (CFRP) and Kevlar/Glass hybrid fabric (K/G) retrofitted reinforced concrete (RC) wall is analyzed by using the explicit analysis code LS-DYNA, which accommodates the high-strain rate dependent material models. Also, the retrofit effectiveness of FRP fabrics is evaluated by comparing the analysis results for non-retrofitted and retrofitted walls. The verification of the analysis is performed through comparisons with the previous experimental results.

Keywords

Acknowledgement

Supported by : NRF

References

  1. Al-Hassini, S.T.S. and Kaddour, A.S. (1998), "Strain rate effect on GFRP, KFRP and CFRP composite laminates", Key Eng. Mater., 141-143(2), 427-452. https://doi.org/10.4028/www.scientific.net/KEM.141-143.427
  2. ASCE (1999), "Structural design for physical security", State of the Practice.
  3. Biggs, J.M. (1964), Introduction to Structural Dynamics, McGraw-Hill, New York.
  4. Brena, S.F. and McGuirk, G.N. (2013), "Advances on the behavior characterization of FRP-anchored carbon fiber-reinforced polymer (CFRP) sheets used to strengthen concrete elements", Int. J. Concrete Struct. Mater., 7(1), 3-16. https://doi.org/10.1007/s40069-013-0028-1
  5. Buchan, P.A. and Chen, J.F. (2007), "Blast resistance of FRP composite and polymer strengthened concrete and masonry structures: A state-of-the-art review", Compos. Part B: Eng., 38(5-6), 509-522. https://doi.org/10.1016/j.compositesb.2006.07.009
  6. Chang, F.K. and Chang, K.Y. (1987), "A progressive damage model for laminated composite containing stress concentration", J. Compos. Mater., 21(9), 834-855. https://doi.org/10.1177/002199838702100904
  7. Chen,W.F. (1982), Plasticity in Reinforced Concrete, McGraw Hill, New York.
  8. Grelle, S.V. and Sneed, L.H. (2013), "Review of anchorage system for externally bonded FRP laminates", Int. J. Concrete Struct. Mater., 7(1), 17-33. https://doi.org/10.1007/s40069-013-0029-0
  9. Hashin, Z. (1980), "Failure criteria for unidirectional fiber composite", J. Appl. Mech., 47(2), 329-334. https://doi.org/10.1115/1.3153664
  10. Jerome, D.M. and Ross, C.A. (1997), "Simulation of the dynamic response of concrete beams externally reinforced with carbon-fiber reinforced plastic", Comput. Struct., 64(5-6), 1129-1153. https://doi.org/10.1016/S0045-7949(97)00022-9
  11. Jones, N. (1983), Structural aspects of ship collisions, Ed. Jones N, Wierzbicki T, Structural Crashworthiness, Butterworths, London.
  12. LSTC (2006), LS-DYNA Keyword User's Manual Version 9.71, Livermore Software Technology Corporation.
  13. Malvar, L.J., Morrill, K.B. and Crawford, J.E. (2004), "Numerical modeling of concrete confined by fiberreinforced composites", J. Compos. Constr., 8(4), 315-322. https://doi.org/10.1061/(ASCE)1090-0268(2004)8:4(315)
  14. Muszynski, L.C. and Purcell, M.R. (2003), "Composite reinforcement to strengthen existing concrete structures against air blast", J. Compos. Constr., 7(2), 93-97. https://doi.org/10.1061/(ASCE)1090-0268(2003)7:2(93)
  15. Park, H., Lee, K., Lee, S.W. and Kim, K. (2006), "Dynamic analysis of nonlinear composite structures under pressure wave loading", J. Compos. Mater., 40(15), 1361-1383. https://doi.org/10.1177/0021998306059718
  16. Razaqpur, A.G., Tolba, A. and Contestabile, E. (2007), "Blast loading response of reinforced concrete panels reinforced with externally bonded GFRP laminates", Compos. Part B: Eng., 38(5-6), 535-546. https://doi.org/10.1016/j.compositesb.2006.06.016
  17. Silva, P.F. and Lu, B. (2007), "Improving the blast resistance capacity of RC slabs with innovative composite materials", Compos. Part B: Eng., 38(5), 523-534. https://doi.org/10.1016/j.compositesb.2006.06.015
  18. White, T.W., Soudki, K.A. and Erki, M.A. (2001), "Response of RC beams strengthened with CFRP laminates and subjected to a high rate loading", J. Compos. Constr., 5(3), 153-162. https://doi.org/10.1061/(ASCE)1090-0268(2001)5:3(153)

Cited by

  1. Buckling of concrete columns retrofitted with Nano-Fiber Reinforced Polymer (NFRP) vol.18, pp.5, 2016, https://doi.org/10.12989/cac.2016.18.5.1053
  2. Combined effect of CFRP-TSR confinement on circular reinforced concrete columns vol.19, pp.1, 2017, https://doi.org/10.12989/cac.2017.19.1.041
  3. Numerically and empirically determination of blasting response of a RC retaining wall under TNT explosive vol.5, pp.5, 2017, https://doi.org/10.12989/acc.2017.5.5.493
  4. Ultimate strength and strain models proposed for CFRP confined concrete cylinders vol.29, pp.4, 2018, https://doi.org/10.12989/scs.2018.29.4.465
  5. Numerical investigation of a new structural configuration of a concrete barrier wall under the effect of blast loads vol.11, pp.suppl1, 2016, https://doi.org/10.1007/s40091-019-00252-8
  6. Numerical Evaluation of Reinforced Concrete Columns Retrofitted with FRP for Blast Mitigation vol.2020, pp.None, 2020, https://doi.org/10.1155/2020/8884133
  7. Blasting Response of a Two-Storey RC Building Under Different Charge Weight of TNT Explosives vol.44, pp.2, 2016, https://doi.org/10.1007/s40996-019-00256-0
  8. Uncertainties in blast simulations evaluated with Smoothed Particle Hydrodynamics method vol.74, pp.6, 2016, https://doi.org/10.12989/sem.2020.74.6.771
  9. Blast pressure analysis due to confined explosion-after effects vol.28, pp.None, 2020, https://doi.org/10.1016/j.istruc.2020.08.057