A Study of Sensing Locations for Self-fitness Clothing base on EMG Measurement

셀프 피트니스 의류 개발을 위한 근전도 센싱 위치 연구

  • 조하경 ((주)블랙야크 상품기획부) ;
  • 조상우 (호서대학교 스포츠과학부)
  • Received : 2016.11.10
  • Accepted : 2016.12.29
  • Published : 2016.12.31

Abstract

Recently, interest in monitoring health and sports is growing because of the emphasis on wellness, which is accelerating the development and commercialization of smart clothing for biosignal monitoring. In addition to exerciseeffect monitoring clothing that tracks heart rate and respiration, recently developed clothing makes it possible to monitor muscle balance using electromyogram (EMG). The electrode for EMG have to attached to an accurate location in order to obtain high-quality signals in surface EMG measurement. Therefore, this study develops monitoring clothing suitable for different types of human bodies and aims to extract suitable range of EMG according to movements in order to develop self-fitness monitoring clothing based on EMG measurement. This study identified and attached electrodes on six upper muscles and two lower muscles of ten males in their 20s. After selecting six main motions that create a load on muscles, the 8-ch wireless EMG system was used to measure amplitude value, noise, SNR and SNR (dB) in each part and statistical analysis was conducted using SPSS 20.0. As a result, the suitable range for EMG measurement to apply to clothing was identified as four parts in musculus pectoralis major; three parts in muscle rectus abdominis, two parts each in shoulder muscles, backbone erector, biceps brachii, triceps brachii, and musculus biceps femoris; and four part in quadriceps muscle of thigh. This was depicted diagrammatically on clothing, and the EMG-monitoring sensing locations were presented for development of self-fitness monitoring.

Keywords

References

  1. Athos gear. (n.d.). Athos. Retrieved November 15, 2016, from http://www.liveathos.com
  2. Catherwood, P. A., Donnelly, N., Anderson, J., & McLaughlin, J. (2010). ECG motion artefact reduction improvements of a chest-based wireless patient monitoring system. In Computing in Cardiology (pp. 557-560). IEEE.
  3. Cho, G. S., Yang, Y. J., & Sung, M. S. (2008). Development and its present status of bio-monitoring smart clothing and e-textiles. Fashion & Textile Research Journal, 10(1), 1-10.
  4. Cho, H. K., & Cho, S. W. (2015). A study of sensing locations for ECG monitoring clothing based on the skin change rate. Fashion & Textile Research Journal, 17(5), 844-853. doi:10.5805/SFTI.2015.17.5.844
  5. Guerreiro, T. J. V., Jorge, J. A. P., Jo, T., Armando, J., & Jorge, P. (2006). EMG as a daily wearable interface. In GRAPP (pp. 216-223).
  6. Han, H. Y., & Kim, J. (2010). Prediction of the upper limb motion based on a geometrical muscle changes for physical human machine interaction. Journal of Institute of Control, Robotics and Systems, 16(10), 927-932. doi:10.5302/J.ICROS.2010.16.10.927
  7. Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000). Development of recommendations for SEMG sensors and sensor placement procedures. Journal of Electromyography and Kinesiology, 10(5), 361-74. doi:10.1016/S1050-6411(00)00027-4
  8. Hong, H. S., Park, S., & Hong, S. D. (2010). The technology forecasting for the biometrics systems by using delphi method. The Korea Academia-Industrial Cooperation Society, 11(9), 3204-3209. doi:10.5762/KAIS.2010.11.9.3204
  9. Huang, H. Y., Lin, J. J., Guo, Y. L., Wang, T. J., & Chen, Y. J. (2013). EMG biogeedback effectiveness to alter muscle activity pattern and scapular kinematics in subjects with and without shoulder impingement. Journal of Electromyography and Kinesiology, 23(1), 267-274. doi:10.1016/j.jelekin.2012.09.007
  10. Hwang, Y. M., & Lee, J. R. (2013). Development and evaluation of smart foundation with heating devices. Fashion & Textile Research Journal, 15(2), 231-239. doi:10.5805/SFTI.2013.15.2.231
  11. Kang, H. J., Lee, B. K., & Kim, K. H. (2014). Effects of functional elastic stocking application on repetition and EMG response during squats. The Official Journal of the Korean Association of Certified Exercise Professionals, 16(3), 49-58. doi:10.15758/jkak.2014.16.3.49
  12. Kim, K. C., Kang, M. S., Ji, C. U., Ha, J. W., Sun, D. I., Xue, G., & Shin, K. S. (2016). A research for interface based on EMG pattern combinations of commercial gesture controller. Journal of Engineering Education Research, 19(1), 31-36. https://doi.org/10.18108/jeer.2016.19.1.31
  13. Koo, H. R., Lee Y. J., Gi, S. O., Lee, S. P., Kim, K. N., Kang, S. J., Lee, J. W., & Lee, J. H. (2015). Effect of module design for a garment-type heart activity monitoring wearable system based on non-contact type sensing. Journal of the Korean Society of Clothing and Textiles, 39(3), 369-378. doi:10.5850/JKSCT.2015.39.3.369
  14. Kundu, A. S., Mazumder, O., & Bhaumik, S. (2011). Design of wearable, low power, single supply surface EMG extractor unit for wireless monitoring. 2011 International Conference on Nanotechnology and Biosensors IPCBEE, 25, pp. 69-74. Singapore: IACSIT Press.
  15. Lee, J. H., & Jeong, K. S. (2016). A study on the commercialization technology development model of U-health smart clothing - Focused on the ECG measuring smart clothing for people in 40s to 60s -. Journal of the Korean Society of Fashion Design, 16(2), 49-63.
  16. Lee, J. W., Kim, D. H., Ryoo, H. Y., & Shin, B. S. (2016). Sustainable wearables: Wearable technology for enhancing the quality of human life. Sustainability, 8(5), 466. doi:10.3390/su8050466
  17. Lee, H. K. (2014). Compare on the iEMG and MDF according to performance of the 3 different ways during back squat exercising. Journal of Physical Growth and Motor Development, 22(4), 349-354.
  18. Mbody. (n.d.). Myontec. Retrieved November 15, 2016, from http://www.myontec.com/products/mbody/
  19. Min, B. C., Kim, J. H., Jeon, K. J., Lee, D. H., & Kim, J. S. (2005). EMG Fatigue comparative study of stair ascending and descending. The Society of Korea Industrial and Systems Engineering, 10, 60-63.
  20. Min, S. D., Yun, Y. H., Lee, C. K., Shin, H. S., Cho, H. K., Hwang, S. C., & Lee, M. H. (2010). Respiration measurement system using textile capacitive pressure sensor. The Transactions of the Korean Institute of Electrical Engineers P, 59(1), 58-63.
  21. Peak, K. J., & Lee, J. R. (2014). Draft proposal of smart outdoor wear upon the outdoor wear functionality demand. Fashion & Textile Research Journal, 16(3), 446-455. doi:10.5805/SFTI.2014.16.3.446
  22. Park, J. M. (2013). Technological issues for body information monitoring. The Journal of Korea Information and Communications Society, 38(2), 105-114. doi:10.7840/kics.2013.38B.2.105
  23. Sornmo, L., & Laguna, P. (2006). Electrocardiogram (ECG) signal processing. Wiley Encyclopedia of Biomedical Engineering. doi:10.1002/9780471740360.ebs1482
  24. Song, H. Y., Lee, J. H., Kang, D., Cho, H., Cho, H. S., Lee, J. W., & Lee, Y. J. (2010). Textile electrodes of jacquard woven fabrics for biosignal measurement. The Journal of the Textile Institute, 101(8), 758-770. https://doi.org/10.1080/00405000903442086
  25. Suh, S. E., & Roh, J. S. (2015). A study on smart fashion product development trends. The Research Journal of the Costume Culture, 23(6), 1097-1115. doi:10.7741/rjcc.2015.23.6.1097
  26. Yu, H. J., Lee, H. C., & Choi, Y. J. (2007). Biomedical EMG sensor development and its application. The 2st Korea Robotics Society Conference on Advanced Intelligent Robots, pp. 201-206.
  27. Won, N. S., & Yun, J. H. (2015). Smart clothes and efficient method supporting health using EMG sensors. Conference of the Korea Institute of Information Scientists and Engneers, 12, pp. 999-1001.

Cited by

  1. Evaluation of Muscle Activity as Influenced by Shape and Arrangement of the EMG Electrodes in the Musculature of the Upper and Lower Extremities vol.26, pp.5, 2017, https://doi.org/10.5934/kjhe.2017.26.5.445