Abstract

Stainless steel wire mesh (SSWM) is an alternative material for strengthening of structural elements similar to fiber reinforced polymer (FRP). Finite element (FE) method based Numerical investigation for evaluation of axial strength of SSWM strengthened plain cement concrete (PCC) and reinforced cement concrete (RCC) columns is presented in this paper. PCC columns of 200 mm diameter with height 400 mm, 800 mm and 1200 mm and RCC columns of diameter 200 mm with height of 1200 mm with different number of SSWM wraps are considered for study. The effect of concrete grade, height of column and number of wraps on axial strength is studied using finite element based software ABAQUS. The results of numerical simulation are compared with experimental study and design guidelines specified by ACI 440.2R-08 and CNR-DT 200/2004. As per numerical analysis, an increase in axial capacity of 15.69% to 153.95% and 52.39% to 109.06% is observed for PCC and RCC columns respectively with different number of SSWM wraps.

Keywords

References

  1. ABAQUS User's Manual, Ver. 6.10, Hibbit, Karlsson and Sorensen, Inc., Paw-tucket, Rhode Island.
  2. ACI 440.2R (2008), Guide for the Design and Construction of Externally Bonded FRP Systems for strengthening Concrete Structures, American Concrete Institute, Country Club Drive, Farmington Hills, MI 48331, U.S.A.
  3. Allam, S., Shoukry, M., Rashad, G. and Hassan, A. (2013), "Evaluation of tension stiffening effect on the crack width calculation of flexural RC members", Alexan. Eng. J., 52, 163-173. https://doi.org/10.1016/j.aej.2012.12.005
  4. CNR-DT 200 (2004), Guide for the design and construction of Externally Bonded FRP systems for strengthening existing structures, CNR-Advisory Committee on Technical Recommendations for Construction.
  5. Coronado, C.A. and Lopez, M. (2007), "Damage approach for the prediction of Debonding failure on concrete elements strengthened with FRP", J. Compos. Construct., 11, 391-400. https://doi.org/10.1061/(ASCE)1090-0268(2007)11:4(391)
  6. Gambarelli, S., Nistico, N. and Ozbolt, J. (2014), "Numerical analysis of compressed concrete columns confined with CFRP: Microplane-based approach", Compos. Part B, 67, 303-312. https://doi.org/10.1016/j.compositesb.2014.06.026
  7. Hu, B. (2013), "An improved criterion for sufficiently/insufficiently FRP-confined concrete derived from ultimate axial stress", Eng. Struct., 46, 431-446. https://doi.org/10.1016/j.engstruct.2012.08.001
  8. Hu, D. and Barbato, M. (2014), "Simple and efficient finite element modelling of reinforced concrete columns confined with fiber-reinforced polymers", Eng. Struct., 72, 113-122. https://doi.org/10.1016/j.engstruct.2014.04.033
  9. Hu, H.T., Lin, F.M., Liu H.T, Huang Y.F and Pan T.C. (2010), "Constitutive modelling of reinforced concrete and prestressed concrete structures strengthened by fiber-reinforced plastics", J. Compos. Struct., 92, 1640-1650. https://doi.org/10.1016/j.compstruct.2009.11.030
  10. IRC:112 (2011), Code of practice for concrete road bridges, Indian Road Congress, New Delhi, India.
  11. IS 456 (2000), Plain and Reinforced concrete code of practice, Bureau of Indian Standards, New Delhi, India.
  12. Karabinis, A.I., Rousakis, T.C. and Manolitsi, G.E. (2008), "3D Finite-element analysis of substandard RC columns strengthened by fiber-reinforced polymer sheets", J. Compos. Construct., 12, 531-540. https://doi.org/10.1061/(ASCE)1090-0268(2008)12:5(531)
  13. Kumar, V. and Patel, P.V. (2016), "Strengthening of axially loaded circular concrete columns using stainless steel wire mesh (SSWM)-Experimental Investigations", Constr. Build. Mater., 124, 186-198. https://doi.org/10.1016/j.conbuildmat.2016.06.109
  14. Massicotte, B., Elwi, A. and MacGregor, J. (1990), "Tension-stiffening model for planar reinforced concrete members", J. Struct. Eng., ASCE, 116, 3039-3058. https://doi.org/10.1061/(ASCE)0733-9445(1990)116:11(3039)
  15. Obaidat, Y., Heyden, S. and Dahlblom, O. (2010), "The effect of CFRP and CFRP/concrete interface models when modelling retrofitted RC beams with FEM", J. Compos. Struct., 92, 1391-1398. https://doi.org/10.1016/j.compstruct.2009.11.008
  16. Ozbakkaloglu, T., Lim, J. and Vincent, T. (2013), "FRP-confined concrete in circular sections: Review and assessment of stress-strain models", Eng. Struct., 49, 1068-1088. https://doi.org/10.1016/j.engstruct.2012.06.010
  17. Rocca, S., Galati, N. and Nanni, A. (2008), "Review of design guidelines for FRP confinement of reinforced concrete columns of noncircular cross sections", J. Compos. Construct., 12(1), 80-92. https://doi.org/10.1061/(ASCE)1090-0268(2008)12:1(80)
  18. Saenz, L.P. (1964), "Equation for the stress-strain curve of concrete", ACI Struct. J., 61, 1229-1235.
  19. Tao, Y. and Chen, J. (2014), "Concrete damage plasticity model for modelling FRP-to-concrete bond behaviour", J. Compos. Construct., ASCE, 19(1), 04014026. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000482
  20. Turon, A., Davila, C., Camanho, P. and Costa, J. (2007), "An engineering solution for mesh size effects in the simulation of delamination using cohesive zone models", Eng. Fract. Mech., 74, 1665-1682. https://doi.org/10.1016/j.engfracmech.2006.08.025
  21. Zare, A. and Janghorban, M. (2013), "Shock factor investigation in a 3-D finite element model under shock loading", Latin Am. J. Solid. Struct., 10, 941-952, https://doi.org/10.1590/S1679-78252013000500005

Cited by

  1. Seismic response of concrete columns with nanofiber reinforced polymer layer vol.20, pp.3, 2016, https://doi.org/10.12989/cac.2017.20.3.361
  2. Experimental and FE simulations of ferrocement columns incorporating composite materials vol.64, pp.2, 2016, https://doi.org/10.12989/sem.2017.64.2.155
  3. Torsional strengthening of RC beams using stainless steel wire mesh -Experimental and numerical study vol.67, pp.4, 2016, https://doi.org/10.12989/sem.2018.67.4.391
  4. Compressive behavior of galvanized steel wire mesh (GSWM) strengthened RC short column of varying shapes vol.7, pp.3, 2020, https://doi.org/10.12989/smm.2020.7.3.215