A compactly integrated cooling system of a combination dual 1.5-MW HTS motors for electric propulsion

  • Le, T.D. (Department of Electrical Engineering, Jeju National University) ;
  • Kim, J.H. (Department of Electrical Engineering, Jeju National University) ;
  • Hyeon, C.J. (Department of Electrical Engineering, Jeju National University) ;
  • Kim, D.K. (Faculty of Wind Energy Engineering, Jeju National University) ;
  • Yoon, Y.S. (Department of Electrical Engineering, Shin Ansan University) ;
  • Lee, J. (Department of Electrical and Electronic Engineering, Yonsei University) ;
  • Park, Y.G. (Department of Electrical and Electronic Engineering, Yonsei University) ;
  • Jeon, H. (Department of Electrical and Electronic Engineering, Yonsei University) ;
  • Quach, H.L. (Department of Electrical, Electronic and Telecommunication Engineering, Can Tho University of Technology) ;
  • Kim, H.M. (Department of Electrical Engineering, Jeju National University)
  • Received : 2016.10.12
  • Accepted : 2016.12.17
  • Published : 2016.12.31

Abstract

The high temperature superconducting (HTS) contra-rotating propulsion (CRP) systems comprise two coaxial propellers sited on behind the other and rotate in opposite directions. They have the hydrodynamic advantage of recovering the slipstream rotational energy which would otherwise be lost to a conventional single-screw system. However, the cooling systems used for HTS CRP system need a high cooling power enough to maintain a low temperature of 2G HTS material operating at liquid neon (LNe) temperature (24.5 - 27 K). In this paper, a single thermo-syphon cooling approach using a Gifford-McMahon (G-M) cryo-cooler is presented. First, an optimal thermal design of a 1.5 MW HTS motor was conducted varying to different types of commercial 2G HTS tapes. Then, a mono-cryogenic cooling system for an integration of two 1.5 MW HTS motors will be designed and analyzed. Finally, the 3D finite element analysis (FEA) simulation of thermal characteristics was also performed.

Keywords

References

  1. D. Laskos, 'Design and cavitation performance of contra-rotating propeller', Ph.D. thesis, Massachusetts Institute of Technology, 2010.
  2. D. Zhou, Mitsuru, M. Miki, B. Felder, T. Ida, and M. Kitan, "An overview of rotating machine systems with high-temperature bulk superconductors," Supercond. Sci. Technol., vol 25, p. 103001, 2012. https://doi.org/10.1088/0953-2048/25/10/103001
  3. I. Whitelegg, R. Bucknall, "Electrical propulsion in the low carbon economy," Low Carbon Shipping Conference, London, 2013.
  4. A. T. A. M. de Waele, "Basic operation of cryocooler and related thermal machines," Journal of Low Temperature Physics, vol. 164, no. 5-6, p. 179236, 2011.
  5. R. Radebaugh, "Cryocoolers: the state of the art and recent developments," Journal of Physis-Condensed Matter, vol. 21, pp. 1-9, 2009.
  6. T. Zhang, K. Haran, E. T. Laskaris, and J. W. Bray, "Design and test of a simplified and reliable cryogenic system for high-speed superconducting generator applications," Cryogenics, vol. 51, pp. 380-383, 2011. https://doi.org/10.1016/j.cryogenics.2011.03.004
  7. B. Felder, M. Miki, K. Tsuzuki, N. Shinohara, H. Hayakawa, and M. Izumi, "A 100-W grade closed-cycle Thermosyphon cooling system used in HTS rotating machines," Advances in Cryogenic Engineering, vol. 57, pp. 417-424, 2012.
  8. A. R. Kim, K. M. Kim, H. Park, G. H. Kim, T. J. ark, M. Park, S. Kim, S. Lee, H. Ha, S. Yoon, and H. Lee, "Performance analysis of a 10-kW superconducting synchronous generator," IEEE Trans. Appl. Supercond. vol. 25, no. 3, p. 5202004, 2015.
  9. T. D. Le, J. H. Kim, S. I. Park, and H. M. Kim, "Conceptual design of current lead for large scale high temperature superconducting rotating machine," Prog Supercond and Cryo, vol. 16, no. 2, pp. 54-58, 2014. https://doi.org/10.9714/psac.2014.16.2.054
  10. T. D. Le, J. H. Kim, S. I. Park, D. H. Kang, H. G. Lee, Y. S. Jo, Y. S. Yoon, and H. M. Kim, "Thermal design of a cryogenics cooling system for a 10 MW class high-temperature superconducting rotating machine," IEEE Trans. Appl. Supercond. vol. 25, no. 3, p. 3800305, 2015.
  11. Y. Iwasa, Case Studies in Superconducting Magnets, 2nd ed., Springer, New York, pp. 248-250, 2009.
  12. 2G HTS Wire Specification Overview, http://www.superpower-inc.com/content/wire-specification.
  13. Y. Iwasa, Case Studies in Superconducting Magnets, 2nd ed., Springer, New York, pp. 370-373, 2009.
  14. K. Berger, J. Leveque, D. Netter, B. Douine, and A. Rezzoug, "Influence of temperature and/or field dependences of the E-J power law on trapped magnetic field in bulk YBaCuO," IEEE Trans. Appl. Supercond. vol. 17, no. 2, pp. 3028-3031, 2007. https://doi.org/10.1109/TASC.2007.902095
  15. N. Schonborg and S. P. Hornfeldt, "Model of the flux flow losses in a high-temperature superconducting tape exposed to both AC and DC transport currents and magnetic field," IEEE Trans. Appl. Supercond., vol. 11, no. 3, pp. 4078-4085, 2001. https://doi.org/10.1109/TASC.2001.962258
  16. T. Qu, Q. Wu, F. Feng, P. Song, Z. Hong, R. Sun, C. Gu, and Z. Han, "Design and test of a novel thermal insulated torque coupling for a 15-kW fully HTS synchronous generator," IEEE Trans. Appl. Supercond., vol. 26, no. 3, p. 5203105, 2016.