DOI QR코드

DOI QR Code

A Study on the Flame Growth Characteristics of Household Items(Refrigerator·Washing machine·Drawer·Sofa)

생활용품(냉장고·세탁기·장롱·소파)의 화재성장 특성 연구

  • Park, Young Ju (Department of Fire & Emergency Management, Kangwon National University)
  • Received : 2015.05.20
  • Accepted : 2015.06.19
  • Published : 2015.06.30

Abstract

This study was full-scale combustion test for flame growth characteristics and temperature characteristics analysis to predict the risk of household Items fire when fire occurs. Experimental results, Refrigerator flames were the highest measured in 15 min time, and Washing machine is between 20 ~ 30 min, Drawer is 5 min, Sofa was enabled up to the size of the flame 15 min. In addition, the maximum combustion temperature was found from the time 20 min ~ 25 min, Sofa is temperature was elevated up to $1190^{\circ}C$, Refrigerator is $1,162^{\circ}C$, Drawer is $822^{\circ}C$, Washing machine appeared to be rising up to $670^{\circ}C$. Therefore, in the case of the maximum temperature of combustion Sofa it showed relatively high.

Keywords

References

  1. V. Barauskas and R. D. Peacock, "Heat Release Rate : the Single Most Important Variable in Fire Hazard", Fire Safety Journal , Vol. 18, Issue 3, pp. 255-272, 1992. https://doi.org/10.1016/0379-7112(92)90019-9
  2. ISO 5660, "Reaction to Fire Tests : Heat Release, Smoke Production and Mass Loss Rate"
  3. ISO 5660-1, "Reaction-to-fire tests : Heat Release, Smoke Production and Mass Loss Rate, Part 1: Heat Release Rate(Cone Calorimeter Method)
  4. ISO 9705, "Room Corner Tests : Full Scale Room Test for Surface Products"
  5. ISO 13784-1, "Reaction to Fire Tests for Sandwich Panel Building Systems"
  6. KS F ISO 13784, "Sandwich Panel Test"
  7. ASTM E 603, "Standard Guide for Room Fire Experiments"
  8. ASTM E 1317, "Standard Test Method for Flammability of Marine Surface Finishes"
  9. ASTM E 1354, "Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products using an Oxygen Consumption Calorimeter"
  10. ASTM E 1537, "Standard Test Method for Fire Testing of Upholstered Furniture"
  11. BS 476 part 15, "Fire Tests on Building Materials and Structures-Method for Measuring the Rate of Heat Release of Products".
  12. BS EN 13823, "Reaction to fire Tests for Building Products-Building Products Excluding Floorings Exposed to the Thermal Attack by a Single Burning Item"
  13. R. V. Petrella, "The Assessment of Full-scale Fire Hazards from Cone Calorimeter Data", Journal of Fire Sciences , Vol. 12, No. 1, pp. 68-72, 1994.
  14. PR EN 14390, "Fire Test : Full Scale Room Test for Surface Products"
  15. IEC 60332-3, "Cable Testing Rig : Ignitability and Burning Behaviors of Materials and Products"
  16. EN 45545, "Railway Applications : Fire Protection on Railway Vehicles"
  17. EN 50399, "Common Test Methods for Cables under Fire Conditions"
  18. K. O. Lee and K. J. Kim, "A Study on the Structural Reform of Urban Transit Vehicle Considering Elevation of Fire Safety", Journal of the Korean Society of Safety, Vol. 21, No. 5, pp. 22-27, 2006.
  19. J. H. Lee, "A Study on the Weighting of Fire Safety Attributes for Fire Risk Assessment in Historic Buildings -Focused on NakSansa", Journal of the Korean Society of Safety, Vol. 27, No. 3, pp. 189-196, 2012. https://doi.org/10.14346/JKOSOS.2012.27.3.189
  20. D. H. Rie, "A Study on the Development of Performance Based Fire Risk Assesment Program", Journal of the Korean Society of Safety, Vol. 23, No. 5, pp. 1-6, 2008.
  21. S. H. Hong, B. Y. Lee, S. T. Park and H. J. Yu, "An Experimental Study on the Fire Hazards in Electric Heater", Journal of the Korean Society of Safety, Vol. 22, No. 2, pp. 36-40, 2007.
  22. Y. K. Yoon et al, "Fire Dynamics", Hwasumok Publishing Group, pp. 157-186, 2015.