DOI QR코드

DOI QR Code

High-order, closely-spaced modal parameter estimation using wavelet analysis

  • Le, Thai-Hoa (Department of Civil and Environmental Engineering, Northeastern University) ;
  • Caracoglia, Luca (Department of Civil and Environmental Engineering, Northeastern University)
  • 투고 : 2015.04.10
  • 심사 : 2015.10.20
  • 발행 : 2015.11.10

초록

This study examines the wavelet transform for output-only system identification of ambient excited engineering structures with emphasis on its utilization for modal parameter estimation of high-order and closely-spaced modes. Sophisticated time-frequency resolution analysis has been carried out by employing the modified complex Morlet wavelet function for better adaption and flexibility of the time-frequency resolution to extract two closely-spaced frequencies. Furthermore, bandwidth refinement techniques such as a bandwidth resolution adaptation, a broadband filtering technique and a narrowband filtering one have been proposed in the study for the special treatments of high-order and closely-spaced modal parameter estimation. Ambient responses of a 5-story steel frame building have been used in the numerical example, using the proposed bandwidth refinement techniques, for estimating the modal parameters of the high-order and closely-spaced modes. The first five natural frequencies and damping ratios of the structure have been estimated; furthermore, the comparison among the various proposed bandwidth refinement techniques has also been examined.

키워드

참고문헌

  1. Brincker, R., Ventura, C. and Andersen, P. (2001), "Damping estimation by frequency domain decomposition", Proceedings of International Modal Analysis Conference (IMAC XIX), Kissimmee, USA.
  2. Chen, S.L., Liu, J.J. and Lai, H.C. (2008), "Wavelet analysis for identification of damping ratios and natural frequency", Sound Vib., 323, 130-147.
  3. Caracoglia, L. and Velazquez, A. (2008), "Experimental comparison of the dynamic performance for steel, aluminum and glass-fiber-reinforced-polymer light poles", Eng. Struct., 30(4), 1113-1123. https://doi.org/10.1016/j.engstruct.2007.07.024
  4. Daubechies, I. (1992), Ten Lectures on Wavelets, CBMS-NSF.
  5. Kijewski, T.L. and Kareem, A. (2003), "Wavelet transforms for system identification: considerations for civil engineering applications", Comput. Aid. Civil Infrast. Eng., 18, 341-357.
  6. Kuroiwa, T. and Iemura, H. (2007), "Comparison of modal identification of output-only systems with simultaneous and nonsimultaneous monitoring", Proceedings the World Forum on Smart Materials an Smart Structures Technology (SMSST07), Chongqing & Nanjing, China.
  7. Ladies, J. and Gouttebroze, S. (2002), "Identification of modal parameters using wavelet transform", J. Mech. Sci., 44, 2263-2283. https://doi.org/10.1016/S0020-7403(02)00175-3
  8. Meo, M., Zumpano, G., Meng, X., Cosser, E., Roberts, G. and Dodson, A. (2006), "Measurement of dynamic properties of a medium span suspension bridge by using the wavelet transform", Mech. Syst. Signal Pr., 20, 1112-1133. https://doi.org/10.1016/j.ymssp.2004.09.008
  9. Peng, Z.K., Tse, P.W. and Chu, F.L. (2005), "A comparison study of improved Hilbert-Huang transform and wavelet transform: Application to fault diagnosis for rolling bearing", Mech. Syst. Signal Pr., 19, 974-988. https://doi.org/10.1016/j.ymssp.2004.01.006
  10. Ruzzene, M., Fasana, A., Garibaldi, L. and Piombo, B. (1997), "Natural frequencies and damping identification using wavelet transform: Application to real data", Mech. Syst. Signal Pr., 11(2), 207-218. https://doi.org/10.1006/mssp.1996.0078
  11. Tan, J.B., Liu, Y., Wang, L. and Yang, W.G. (2008), "Identification of modal parameters of a system with high damping and closed spaced modes by combining continuous wavelet transform with pattern search", Mech. Syst. Signal Pr., 22, 1055-1060. https://doi.org/10.1016/j.ymssp.2007.11.017
  12. Torrence, C. and Compo, G.P. (1998), "A practical guide to wavelet analysis", Bull. Am. Meteorol. Soc., 79(1), 61-78. https://doi.org/10.1175/1520-0477(1998)079<0061:APGTWA>2.0.CO;2
  13. Slavic, J., Simonovski, I. and Boltezar, M. (2003), "Damping identification using a continuous wavelet transform: application to real data", J. Sound Vib., 262, 291-307. https://doi.org/10.1016/S0022-460X(02)01032-5
  14. Staszewski, W.J. (1997), "Identification of damping in MDOF systems using time-scale decomposition", Sound Vib., 203 (2), 283-305. https://doi.org/10.1006/jsvi.1996.0864
  15. Yan, B.F., Miyamoto, A. and Bruhwiler, E. (2006), "Wavelet transform-based modal parameter identification considering uncertainty", Sound Vib., 291, 285-301. https://doi.org/10.1016/j.jsv.2005.06.005

피인용 문헌

  1. Mode identifiability of a cable-stayed bridge using modal contribution index vol.20, pp.2, 2017, https://doi.org/10.12989/sss.2017.20.2.115
  2. System Identification of Structures with Severe Closely Spaced Modes Using Parametric Estimation Algorithms Based on Complex Mode Indicator Function with Singular Value Decomposition vol.24, pp.9, 2015, https://doi.org/10.1007/s12205-020-1068-0
  3. Tracking the variation of complex mode shapes for damage quantification and localization in structural systems vol.169, pp.None, 2022, https://doi.org/10.1016/j.ymssp.2021.108731