Incorporation preference for rubber-steel bearing isolation in retrofitting existing multi storied building

  • Islam, A.B.M. Saiful (Department of Civil Engineering, University of Malaya) ;
  • Jumaat, Mohd Zamin (Department of Civil Engineering, University of Malaya) ;
  • Hussain, Raja Rizwan (CoE-CRT, Department of Civil Engineering, College of Engineering, King Saud University) ;
  • Hosen, Md. Akter (Department of Civil Engineering, University of Malaya) ;
  • Huda, Md. Nazmul (Department of Civil Engineering, University of Malaya)
  • 투고 : 2014.04.08
  • 심사 : 2015.07.26
  • 발행 : 2015.10.25

초록

Traditionally, multi-story buildings are designed to provide stiffer structural support to withstand lateral earthquake loading. Introducing flexible elements at the base of a structure and providing sufficient damping is an alternative way to mitigate seismic hazards. These features can be achieved with a device known as an isolator. This paper covers the design of base isolators for multi-story buildings in medium-risk seismicity regions and evaluates the structural responses of such isolators. The well-known tower building for police personnel built in Dhaka, Bangladesh by the Public Works Department (PWD) has been used as a case study to justify the viability of incorporating base isolators. The objective of this research was to establish a simplified model of the building that can be effectively used for dynamic analysis, to evaluate the structural status, and to suggest an alternative option to handle the lateral seismic load. A finite element model was incorporated to understand the structural responses. Rubber-steel bearing (RSB) isolators such as Lead rubber bearing (LRB) and high damping rubber bearing (HDRB) were used in the model to insert an isolator link element in the structural base. The nonlinearities of rubber-steel bearings were considered in detail. Linear static, linear dynamic, and nonlinear dynamic analyses were performed for both fixed-based (FB) and base isolated (BI) buildings considering the earthquake accelerograms, histories, and response spectra of the geological sites. Both the time-domain and frequency-domain approaches were used for dynamic solutions. The results indicated that for existing multi-story buildings, RSB diminishes the muscular amount of structural response compared to conventional non-isolated structures. The device also allows for higher horizontal displacement and greater structural flexibility. The suggested isolation technique is able to mitigate the structural hazard under even strong earthquake vulnerability.

키워드

과제정보

연구 과제 주관 기관 : University of Malaya (UM)

참고문헌

  1. Ahmad, S., Ghani, F. and Raghib Adil, M. (2009), "Seismic friction base isolation performance using demolished waste in masonry housing", Constr. Build. Mater., 23(1), 146-152. https://doi.org/10.1016/j.conbuildmat.2008.01.012
  2. Anzani, A., Binda, L., Carpinteri, A., Invernizzi, S. and Lacidogna, G. (2010), "A multilevel approach for the damage assessment of Historic masonry towers", J. Cultur. Heritage, 11(4), 459-470. https://doi.org/10.1016/j.culher.2009.11.008
  3. Ariga, T., Kanno, Y. and Takewaki, I. (2006), "Resonant behaviour of base-isolated high-rise buildings under long-period ground motions", Struct. Des. Tall Spec. Build., 15(3), 325-338. https://doi.org/10.1002/tal.298
  4. Ates, S. (2012), "Investigation of effectiveness of double concave friction pendulum bearings", Comput. Concrete, 9(3), 195-213. https://doi.org/10.12989/cac.2012.9.3.195
  5. Ates, S. and Yurdakul, M. (2011), "Site-response effects on RC buildings isolated by triple concave friction pendulum bearings", Comput. Concrete, 8(6), 693-715. https://doi.org/10.12989/cac.2011.8.6.693
  6. Bangladesh National Building Code (1993), BNBC, Bangladesh: Housing and Building Research Institute, Bangladesh Standard and Testing Institute.
  7. Baratta, A. and Corbi, I. (2004), "Optimal design of base-isolators in multi-storey buildings", Comput. Struct., 82(23-26), 2199-2209. https://doi.org/10.1016/j.compstruc.2004.03.061
  8. Betti, M. and Vignoli, A. (2011), "Numerical assessment of the static and seismic behaviour of the basilica of Santa Maria all'Impruneta (Italy) ", Constr. Build. Mater., 25(12), 4308-4324. https://doi.org/10.1016/j.conbuildmat.2010.12.028
  9. Borzi, B., Vona, M., Masi, A., Pinho, R. and Pola, D. (2013), "Seismic demand estimation of RC frame buildings based on simplified and nonlinear dynamic analyses", Earthq. Struct., 4(2), 157-179. https://doi.org/10.12989/eas.2013.4.2.157
  10. Casciati, F. and Hamdaoui, K. (2008), "Modelling the uncertainty in the response of a base isolator", Probab. Eng. Mech., 23(4), 427-437. https://doi.org/10.1016/j.probengmech.2007.10.014
  11. Dall'Asta, A. and Ragni, L. (2006), "Experimental tests and analytical model of high damping rubber dissipating devices", Eng. Struct., 28(13), 1874-1884. https://doi.org/10.1016/j.engstruct.2006.03.025
  12. Dall'Asta, A. and Ragni, L. (2008), "Nonlinear behavior of dynamic systems with high damping rubber devices", Eng. Struct., 30(12), 3610-3618. https://doi.org/10.1016/j.engstruct.2008.06.003
  13. Dicleli, M. and Buddaram, S. (2007), "Comprehensive evaluation of equivalent linear analysis method for seismic-isolated structures represented by sdof systems", Eng. Struct., 29(8), 1653-1663. https://doi.org/10.1016/j.engstruct.2006.09.013
  14. Gursoy, S. (2014), "Investigation of nonlinear behaviour of reinforced concrete frames having different stiffening members", Comput. Concrete, 13(5), 679-694. https://doi.org/10.12989/cac.2014.13.5.679
  15. Habibullah, A. (2007), ETABS: Three Dimensional Analysis of Building Systems, Computers and Structures Inc. Berkeley, California.
  16. Hong, W. and Kim, H. (2004), "Performance of a multi-story structure with a resilient-friction base isolation system", Comput. Struct., 82(27), 2271-2283. https://doi.org/10.1016/j.compstruc.2004.06.002
  17. Iriarte, E., Sanchez, M.A., Foyo, A. and Tomillo, C. (2010), "Geological risk assessment for cultural heritage conservation in karstic caves", J. Cultur. Heritage, 11(3), 250-258. https://doi.org/10.1016/j.culher.2009.04.006
  18. Islam, A.B.M.S., Ahmad, S.I., Jameel, M. and Zamin, M. J. (2012a), "Seismic Base Isolation for Buildings in Regions of Low to Moderate Seismicity: Practical Alternative Design", Prac. Period. Struct. Des. Constr., 17(1), 13-20. https://doi.org/10.1061/(ASCE)SC.1943-5576.0000093
  19. Islam, A.B.M.S., Hussain, R.R., Jumaat, M.Z. and Darain, K.M.U. (2014), "Implication of rubber- steel bearing nonlinear models on soft storey structures", Comput. Concrete, 13(5), 603-669. https://doi.org/10.12989/cac.2014.13.5.603
  20. Islam, A.B.M.S., Hussain, R.R., Jumaat, M.Z. and Rahman, M.A. (2013a), "Nonlinear dynamically automated excursions for rubber-steel bearing isolation in multi-storey construction", Auto. Construct., 30, 265-275. https://doi.org/10.1016/j.autcon.2012.11.010
  21. Islam, A.B.M.S., Jameel, M., Ahmad, S.I., Salman, F.A. and Jumaat, M.Z. (2011), "Engendering earthquake response spectra for Dhaka region usable in dynamic analysis of structures", Scie. Res. Essay., 6(16), 3519-3530. https://doi.org/10.5897/SRE11.218
  22. Islam, A.B.M.S., Jameel, M., Jumaat, M.Z. and Rahman, M.M. (2013b), "Optimization in structural altitude for seismic base isolation at medium risk earthquake disaster region", Disast. Adv., 6(1), 23-34.
  23. Islam, A.B.M.S., Jameel, M., Uddin, M.A. and Jumaat, M.Z. (2012b), "Competent building elevation for incorporating base isolation in aseismic structure", Procedia Eng., 50(0), 882-892. https://doi.org/10.1016/S1877-7058(14)00002-2
  24. Islam, A.B.M.S., Jumaat, M.Z., Hussain, R. and Alam, M.A. (2013c), "Incorporation of rubber-steel bearing isolation in multi-storey building", J. Civil Eng. Manag., 19(sup1), S33-S49. https://doi.org/10.3846/13923730.2013.801904
  25. Ismail, M., Rodellar, J. and Ikhouane, F. (2010), "An innovative isolation device for aseismic design", Eng. Struct., 32(4), 1168-1183. https://doi.org/10.1016/j.engstruct.2009.12.043
  26. Khan, A.A. and Hossain, M.S. (2005), "Recurrence of 1885 Bengal earthquake and hazard vulnerability status of Dhaka Metropolitan City, Bangladesh", Orient. Geograp., 49(2), 205-216.
  27. Kilar, V. and Koren, D. (2009), "Seismic behaviour of asymmetric base isolated structures with various distributions of isolators", Eng. Struct., 31(4), 910-921. https://doi.org/10.1016/j.engstruct.2008.12.006
  28. Lee, S.J., Lee, D.H., Kim, K.S., Oh, J.Y., Park, M.K. and Yang, I.S. (2013), "Seismic performances of RC columns reinforced with screw ribbed reinforcements connected by mechanical splice", Comput. Concrete, 12(2), 131-149 https://doi.org/10.12989/cac.2013.12.2.131
  29. Lu, L.Y. and Lin, G.L. (2008), "Predictive control of smart isolation system for precision equipment subjected to near-fault earthquakes", Eng. Struct., 30(11), 3045-3064. https://doi.org/10.1016/j.engstruct.2008.04.016
  30. Olsen, A., Aagaard, B. and Heaton, T. (2008), "Long-period building response to earthquakes in the San Francisco Bay Area", Bul. Seismol. Soc. Am., 98(2), 1047. https://doi.org/10.1785/0120060408
  31. Ozmen, H.B., Inel, M. and Cayci, B.T. (2013), "Engineering implications of the RC building damages after 2011 Van Earthquakes", Earthq. Struct., 5(3), 297-319. https://doi.org/10.12989/eas.2013.5.3.297
  32. Pocanschi, A. and Phocas, M.C. (2007), "Earthquake isolator with progressive nonlinear deformability", Eng. Struct., 29(10), 2586-2592. https://doi.org/10.1016/j.engstruct.2006.12.016
  33. Providakis, C.P. (2008), "Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations", Eng. Struct., 30(5), 1187-1198. https://doi.org/10.1016/j.engstruct.2007.07.020
  34. Roy, B.K. and Chakraborty, S. (2013), "Optimal design of Base isolation System considering uncertain bounded system parameters", Struct. Eng. Mech., 46(1), 19-37. https://doi.org/10.12989/sem.2013.46.1.019
  35. Xue, X. and Yang, X. (2014), "Earthquake safety assessment of an arch dam using an anisotropic damage model for mass concrete", Comput. Concrete, 13(5), 633-648. https://doi.org/10.12989/cac.2014.13.5.633

피인용 문헌

  1. Potential Design of Seismic Vulnerable Buildings Incorporating Lead Rubber Bearing vol.9, pp.2, 2019, https://doi.org/10.3390/buildings9020037
  2. Seismic response variation of multistory base-isolated buildings applying lead rubber bearings vol.21, pp.5, 2015, https://doi.org/10.12989/cac.2018.21.5.495
  3. Computer aided failure prediction of reinforced concrete beam vol.25, pp.1, 2020, https://doi.org/10.12989/cac.2020.25.1.067