References
- Keall PJ, Mageras GS, Balter JM, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 2006;33:3874-900. https://doi.org/10.1118/1.2349696
- Wilson EM, Williams FJ, Lyn BE, Wong JW, Aird EG. Validation of active breathing control in patients with non-small-cell lung cancer to be treated with CHARTWEL. Int J Radiat Oncol Biol Phys 2003;57:864-74. https://doi.org/10.1016/S0360-3016(03)00712-0
- Stromberg JS, Sharpe MB, Kim LH, et al. Active breathing control (ABC) for Hodgkin's disease: reduction in normal tissue irradiation with deep inspiration and implications for treatment. Int J Radiat Oncol Biol Phys 2000;48:797-806. https://doi.org/10.1016/S0360-3016(00)00681-7
- Mah D, Hanley J, Rosenzweig KE, et al. Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. Int J Radiat Oncol Biol Phys 2000;48:1175-85. https://doi.org/10.1016/S0360-3016(00)00747-1
- Rosenzweig KE, Hanley J, Mah D, et al. The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 2000;48:81-7. https://doi.org/10.1016/S0360-3016(00)00583-6
- Barnes EA, Murray BR, Robinson DM, Underwood LJ, Hanson J, Roa WH. Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration. Int J Radiat Oncol Biol Phys 2001;50:1091-8. https://doi.org/10.1016/S0360-3016(01)01592-9
- Kubo HD, Hill BC. Respiration gated radiotherapy treatment: a technical study. Phys Med Biol 1996;41:83-91. https://doi.org/10.1088/0031-9155/41/1/007
- Ramsey CR, Scaperoth D, Arwood D, Oliver AL. Clinical efficacy of respiratory gated conformal radiation therapy. Med Dosim 1999;24:115-9. https://doi.org/10.1016/S0958-3947(99)00006-0
- Shimizu S, Shirato H, Ogura S, et al. Detection of lung tumor movement in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys 2001;51:304-10.
- Keall PJ, Kini VR, Vedam SS, Mohan R. Motion adaptive x-ray therapy: a feasibility study. Phys Med Biol 2001;46:1-10. https://doi.org/10.1088/0031-9155/46/1/301
- Schweikard A, Shiomi H, Adler J. Respiration tracking in radiosurgery. Med Phys 2004;31:2738-41. https://doi.org/10.1118/1.1774132
- D'Souza WD, Naqvi SA, Yu CX. Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study. Phys Med Biol 2005;50:4021-33. https://doi.org/10.1088/0031-9155/50/17/007
- Suh Y, Yi B, Ahn S, et al. Aperture maneuver with compelled breath (AMC) for moving tumors: a feasibility study with a moving phantom. Med Phys 2004;31:760-6. https://doi.org/10.1118/1.1650565
- He P, Li Q, Liu X, et al. Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery. Med Phys 2014;41:111708. https://doi.org/10.1118/1.4897391
- Pollock S, Lee D, Keall P, Kim T. Audiovisual biofeedback improves motion prediction accuracy. Med Phys 2013;40:041705. https://doi.org/10.1118/1.4794497
- Masselli GM, Silvestri S, Ramella S, Trodella L. Design and evaluation of a methodology to perform personalized visual biofeedback for reducing respiratory amplitude in radiation treatment. Med Phys 2009;36:1467-72. https://doi.org/10.1118/1.3098942
- Lim S, Park SH, Ahn SD, et al. Guiding curve based on the normal breathing as monitored by thermocouple for regular breathing. Med Phys 2007;34:4514-8. https://doi.org/10.1118/1.2795829
- Lim S, Ahn SD, Park SH, et al. Study of respiration simulating phantom using thermocouple-based respiration monitoring mask. J Korean Soc Ther Radiol Oncol 2005;23:217-22.
- Lim S, Jeung TS, Park SH, Ahn SD, Lee S, Kim CY. Determination of target motion by using a respiration monitoring mask for 4-D radiotherapy. J Korean Phys Soc 2008;53:845-50. https://doi.org/10.3938/jkps.53.845
- Ahn YC, Shimizu S, Shirato H, et al. Application of real-time tumor-tracking and gated radiotherapy system for unresectable pancreatic cancer. Yonsei Med J 2004;45:584-90. https://doi.org/10.3349/ymj.2004.45.4.584
- Shimizu S, Shirato H, Kagei K, et al. Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys 2000;46:1127-33. https://doi.org/10.1016/S0360-3016(99)00352-1
- Balter JM, Ten Haken RK, Lawrence TS, Lam KL, Robertson JM. Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. Int J Radiat Oncol Biol Phys 1996;36:167-74.
Cited by
- Intensity-modulated radiotherapy for hepatocellular carcinoma: dosimetric and clinical results vol.8, pp.35, 2017, https://doi.org/10.18632/oncotarget.19219
- Towards Exploring the Benefits of Augmented Reality for Patient Support During Radiation Oncology Interventions vol.9, pp.3, 2015, https://doi.org/10.1080/21681163.2020.1835547