DOI QR코드

DOI QR Code

Design Optimization of Valve Support with Enhanced Seismic Performance

내진성능 향상을 위한 밸브지지대 최적형상 설계

  • Kim, Hyoung Eun (Department of Mechanical Engineering, Andong National University) ;
  • Keum, Dong Yeop (Department of Mechanical Engineering, Andong National University) ;
  • Kim, Dea Jin (Department of Mechanical Engineering, Andong National University) ;
  • Kim, Jun Ho (Department of Research and Development, Korea Gas Cooperation) ;
  • Hong, Seong Kyeong (Department of Research and Development, Korea Gas Cooperation) ;
  • Choi, Won Mok (Department of Research and Development, Korea Gas Cooperation) ;
  • Kim, Sang Yeong (School of Mechanical and Automobile Engineering, Kunsan National University) ;
  • Seok, Chang Seong (Department of Mechanical Engineering, Sungkyunkwan University)
  • 김형은 (안동대학교 기계공학과) ;
  • 금동엽 (안동대학교 기계공학과) ;
  • 김대진 (안동대학교 기계공학과) ;
  • 김준호 (한국가스공사 연구개발원) ;
  • 홍성경 (한국가스공사 연구개발원) ;
  • 최원목 (한국가스공사 연구개발원) ;
  • 김상영 (군산대학교 기계자동차공학부) ;
  • 석창성 (성균관대학교 기계공학과)
  • Received : 2015.03.26
  • Accepted : 2015.09.07
  • Published : 2015.11.01

Abstract

In this study, modal analysis and equivalent static load analysis for valve supports of 26" gas piping in gas stations were conducted and the existing straight and inclined types of valve supports were compared using seismic performance testing. Also, a new valve support shape was suggested by optimizing position of fastener holes, width and thickness of the support, and size of bracket. Improvement in seismic performance by design optimization was verified through equivalent static load analysis. The seismic performance of the newly proposed valve support was greatly improved and the maximum displacement and maximum stress of the seismic load was about 20% lower than those of the existing valve support.

Keywords

References

  1. Nam, M.-J., Park, S.-H., Kim, D.-J., and Choi, J.-S., "Seismic Response Estimation of Water Extinguishing Facilities Using Shaking Table Tests," Journal of the Earthquake Engineering Society of Korea, Vol. 16, No. 4, pp. 9-18, 2012. https://doi.org/10.5000/EESK.2012.16.4.009
  2. Lee, D.-H., Cho, K.-S., Chung, T.-Y., and Kong, J.-S., "Earthquake Response Analysis of a Buried Gas Pipeline," Journal of the Earthquake Engineering Society of Korea, Vol. 11, No. 6, pp. 41-52, 2007. https://doi.org/10.5000/EESK.2007.11.6.041
  3. Koh, J. P., Lim, Y. M., and Lee, K., "Seismic Analysis of Gas Pipelines Subjected to Permanent Ground Deformation," Journal of the Korean Institute of Gas, Vol. 5, No. 3, pp. 9-14, 2001.
  4. Koh, J. P., Hong, S. K., Jung, S. Y., and Kim, J. H., "Assessment of Aseismatic Capability of Electricity Panel in the Governer Station," Proc. of the Korean Institute of Gas Autumn Conference, p. 106, 2013.
  5. Koh, J., Hong, S., Kim, J., and Jeong, S., "The Estimation of Earthquake-Resistance for Gas Utility Using Equivalent Static Analysis," Journal of the Korean Institute of Gas, Vol. 6, No. 4, pp. 23-32, 2002.
  6. Kim, H. E., Keum, Y. D., Park, S. R., Kim, D. J., Kim., J. H., et al., "Evaluation of Seismic Safety for Valve Supporter Using the Equivalent Static Load Method," Proc. of KSPE Spring Conference, pp. 153-154, 2014.
  7. Lee, D. K., "Structural Mechanics for the Seismic Design of Buildings(I, II)," The Korean Structural Engineers Association, Vol. 13, No. 1, 2006.
  8. Kim, Y.-G., Kwon, T.-H., Jeong, Y.-J., Kim, H.-T., and Kim, Y.-J., "Study on Seismic Analysis and Test for Seismic Qualification of 245kV Gis," Transaction of the Korean Society of Mechanical Engineers: A, Vol. 37, No. 5, 2013.
  9. Chirag, S., "Types of Contacts in ANSYS," https://sites.google.com/site/mechanicalengineeringforlife/FEA/typesofcontactsinansys (Accessed 15 October 2015)