References
- Aaleti, S. (2009), "Behavior of rectangular concrete walls subjected to simulated seismic loading", Ph.D. thesis, Department of Civil, Construction and Environmental Engineering, Iowa State University, Ames, IA, USA.
- Aaleti, S., Brueggen, B., Johnson, B., French, C. and Sritharan, S. (2013), "Cyclic response of reinforced concrete walls with different anchorage details: experimental investigation", J. Struct. Eng., ASCE, 139(7), 1181-1191. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000732
- ACI 318 (2011), Building Code Requirements for Structural Concrete (ACI 318M-11) and Commentary, American Concrete Institute, Farmington Hills, U.S.A. ISBN 978-0-87031-745-3.
- Beyer, K., Dazio, A. and Priestley, N.M.J. (2011), "Shear deformations of slender reinforced concrete walls under seismic loading", ACI Struct. J., 108(2), 167-177.
- Birely, A., Lehman, D., Lowes, L., Kuchma, D., Hart, C. and Marley, K. (2010), "Investigation of the seismic response of planar concrete walls", 9th U.S. National Conference and 10th Canadian Conference on Earthquake Engineering, Ontario, Canada.
- Birely, A., Lehman, D., Lowes, L., Kuchma, .D, Hart, C. and Marley, K. (2008), "Investigation of the seismic behavior and analysis of reinforced concrete structural walls", 14th World Conference on Earthquake Engineering, Beijing, China.
- Dazio, A., Beyer, K. and Bachmann, H. (2009), "Quasi-static cyclic tests and plastic hinge analysis of RC structural walls", Eng. Struct., 31(7), 1556-1571. https://doi.org/10.1016/j.engstruct.2009.02.018
- EC2 (2004), BS EN 1992-1-1: Design of concrete structures-General rules and rules for buildings, European Committee for Standardization (CEN), Brussels.
- EC8-I (2004), Design of structures for earthquake resistance - Part 1: General rules seismic actions and rules for buildings, European Committee for Standardization (CEN), Brussels.
- Elnashai, A., Pilakoutas, K. and Ambraseys, N. (1990), ''Experimental behaviour of reinforced concrete walls under earthquake loading", Earthq. Eng. Struct. Dyn., 19(3), 389-407. https://doi.org/10.1002/eqe.4290190308
- Fardis, M.N., Schetakis, A. and Strepelias, E. (2013), "RC buildings retrofitted by converting frame bays into RC walls", Bull. Earthq. Eng., 11(5), 1541-1561. https://doi.org/10.1007/s10518-013-9435-6
- fib CEB-FIP (2010), fib Model Code 2010 - Final draft, Volume 1. Bulletin No. 65, International Federation for Structural Concrete, Lausanne, Switzerland.
- Hannewald, P., Beyer, K. and Mihaylov, B. (2012), "Performance based assessment of existing bridges with wall type piers and structural deficiencies", presented in the ACI341 Session: "Forming a Framework for Performance-based Seismic Design of Concrete Bridges", ACI Fall Convention, Toronto, Canada.
- Hiraishi, H. (1984), "Evaluation of shear and flexural deformations of flexural type shear walls", Bull. NZ. Soc. Earthq. Eng., 17(2), 135-44.
- Jiang, H., Wang, B. and Lu, X. (2013), "Experimental study on damage behavior of reinforced concrete shear walls subjected to cyclic loads", J. Earthq. Eng., 17(7), 958-971. https://doi.org/10.1080/13632469.2013.791895
- Johnson, B. (2010), "Anchorage detailing effects on lateral deformation components of R/C shear walls", M.Sc. Thesis, University of Minnesota, Department of Civil Engineering, 353 pp.
- Massone, L.M. and Wallace, J.W. (2004), "Load-deformation responses of slender reinforced concrete walls", ACI Struct. J., 101(1), 103-113.
- Oesterle, R.G., Aristizabal-Ochoa, J.D., Fiorato, A.E., Russell, H.G. and Corley, W.G. (1979), "Earthquake resistant structural walls - tests of isolated walls: Phase II", Report to National Science Foundation. Skokie (IL, USA): PCA Construction Technology Laboratories.
- Oesterle, R.G., Fiorato, A.E., Johal, L.S., Carpenter, J.E., Russell, H.G. and Corley, W.G. (1976), "Earthquake resistant structural walls - tests of isolated walls", Report to National Science Foundation. Skokie (IL, USA): PCA Construction Technology Laboratories.
- Priestley, M., Seible, F. and Calvi, M. (1996), Seismic Design and Retrofit of Bridges, Wiley, New York, USA.
- Syntzirma, D., Pantazopoulou, S. and Aschheim, M. (2010), "Load-history effects on deformation capacity of flexural members limited by bar buckling", J. Struct. Eng., ASCE, 136(1), 1-11. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000088
- Tastani, S.P. and Pantazopoulou, S.J. (2013a), "Yield penetration in seismically loaded anchorages: effects on member deformation capacity", Earthq. Struct., 5(5), 527-552. https://doi.org/10.12989/eas.2013.5.5.527
- Tastani, S.P. and Pantazopoulou, S.J. (2013b), "Reinforcement-concrete bond: state determination along the development length", J. Struct. Eng., ASCE, 139(9), 1567-1581. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000725
- Thomsen, J.H. and Wallace, J.W. (2004), "Displacement-based design of slender rc structural walls - experimental verification", J. Struct. Eng., ASCE, 130(4), 618-630. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:4(618)
- Thomsen, J.H. and Wallace, J.W. (1995), "Displacement-based design of rc structural walls: an experimental investigation of walls with rectangular and T-shaped cross-sections", Report. No CU/CEE-95/06 to National Science Foundation, Dep. of Civil Engineering, Clarkson University.
- Wallace, J.W., Massone, L.M., Bonelli, P., Dragovich, J., Lagos, R., Luders, C. and Moehle, J. (2012), "Damage and implications for seismic design of RC structural wall buildings", Earthq. Spectra, 28(1), 281-299. https://doi.org/10.1193/1.4000047
- Wallace, J.W. and Moehle, J. (2012) "Behavior and design of structural walls - Lessons from recent laboratory tests and earthquakes", International Symposium on Engineering Lessons Learned from the 2011 Great East Japan Earthquake, Tokyo, Japan.
Cited by
- Mechanics Model for Simulating RC Hinges under Reversed Cyclic Loading vol.9, pp.12, 2016, https://doi.org/10.3390/ma9040305
- Effect of structural features and loading parameters on bond in reinforced concrete under repeated load vol.18, pp.6, 2017, https://doi.org/10.1002/suco.201600170
- Evaluation of load–deformation behavior of reinforced concrete shear walls with continuous or lap-spliced bars in plastic hinge zone pp.2048-4011, 2018, https://doi.org/10.1177/1369433218798717