초록

Connections are the most important regions in a structural system especially for buildings in seismic zones. In R.C. structures due to large dimensions of members and lack of cognition of the stress distribution in a connection, reaching a comprehensive understanding of the connection behaviors becomes more complicated. The shear wall-to-floor slab connections in lateral load resisting systems have a potential weakness in transferring loads from slabs to shear walls which might change the path of load transformation to shear walls. This paper tries to investigate the effects of seismic load combinations on the behavior of slabs at their connection zones with the shear walls. These connection zones naturally are the most critical regions of the slabs in RC buildings. The investigation carried on in a simulated environment by considering three different structures with different shear wall layout. The final results of our study reveal that layout of shear walls in a building significantly affects the magnification of forces developed at the shear wall-floor slab connections.

키워드

참고문헌

  1. American concrete institute (2011), Building code requirements for structural concrete (ACI 318M-11) and commentary, Farmington Hills, Michigan, USA.
  2. American Society of Civil Engineering (2010), "Minimum design loads for buildings and other structures (ASCE/SEI 7-10).
  3. Bari, M.S. (1996), "Nonlinear finite element study of shear wall-floor slab connections", J. Civil. Eng., 24(2), 137-145.
  4. Greeshma, S., Rajesh, C. and Jaya, K.P. (2012), "Seismic behavior of shear wall-slab joint under lateral cyclic loading", Asian. J. Civil. Eng., 13(4), 455-464.
  5. Javan-Hooshiar, A., Banan, Ma.R. and Banan, Mo.R. (2009), "Effect of modeling floor diaphragm flexural rigidity on seismic design of steel buildings with RC shear walls", Proceedings of the 8th ICCE 2009, Shiraz University, Shiraz, Iran.
  6. Kudzys, A., Joh, O., Goto, Y. and Kitano, A. (1995), "Behavior of R/C interior and exterior wall-slab connections under lateral out-plane loading", Japan. Concrete. Ins., 17(2), 1131-1136.
  7. Lee, D.G., Kim, H.S. and Chun, M.H. (2002), "Efficient seismic analysis of high-rise building structures with the effects of floor slabs", Eng. Struct., 24(5), 613-623. https://doi.org/10.1016/S0141-0296(01)00126-2
  8. Nakashima, M., Huang, T. and Lu, L.W. (1982), "Experimental study of beam-supported slabs under in-plane loading", ACI. J. Proc., 79(8), 59-65.
  9. Pantazopoulou, S. and Imran, I. (1992), "Slab-wall connections under lateral forces", ACI. Struct. J., 89(5), 515-527.
  10. Peer ground motion database (2012), "http://peer.berkeley.edu/peer_ground_motion_database"
  11. International Code Council, Inc. (2009), International building code (IBC 2009).
  12. Schwaighofer, J. and Collins, M.P. (1977), "Experimental study of the behavior of reinforced concrete coupling slabs", ACI. J. Proc., 74(12), 123-127.
  13. Wilson, E.L. and Habibullah, A. (2008), ETABS-extended 3D analysis of building systems, Computers and Structures Inc., Berkeley, California, USA.
  14. Wilson, E.L. and Habibullah, A. (2005), "CSI analysis reference manual for SAP2000, ETABS and SAFE", Berkeley, California, USA.

피인용 문헌

  1. Reliability assessment of RC shear wall-frame buildings subjected to seismic loading vol.20, pp.6, 2017, https://doi.org/10.12989/cac.2017.20.6.719