X-ray can be applied to obtain a projection image of an object. It is not easy to obtain an high quality image for the object composed of low and high density materials. For the object with large difference in density, it is possible to realize high contrast image using images of low and high tube voltages and image processing. The plastic and metalic parts of the electronic components can be imaged by the dual energy technique which use low and high tube voltages and by processing pixel-by-pixel using visual C++. The contrast-enhanced image can be used to detect and observe defects within the electronic components.

엑스선을 이용하면 다양한 종류의 시료에 대한 투영 영상을 얻을 수 있다. 시료가 저밀도 및 고밀도의 복합 물질로 구성되어 있는 경우는 단일 관전압 엑스선을 이용해서 두 물질을 모두 대조도가 높도록 영상화하기 어렵다. 저관전압과 고관전압을 이용하여 영상을 획득하고 영상처리하면 밀도의 차이가 큰 물질을 영상화하기에 용이하다. 크기가 작은 전자부품을 저관전압과 고관전압에서 영상을 획득하여 visual C++을 이용하여 픽셀-픽셀 영상 합성을 통하여 전자부품의 합성수지부분과 금속부분을 동시에 영상화하여 전자부품의 검사 및 관찰의 가능성을 검증하였다.

Keywords

References

  1. Zang Hee Cho, Joie P. Jones, Manbir Singh, "Foundations of Medical Imaging," John Wiley & Sons, Inc. 1993.
  2. Alex Pappachen James, Belur V. Dasarathy, "Medical image fusion: A survey of the state of the art," Information Fusion, Vol. 19, No. 4, pp.4-19, 2014. https://doi.org/10.1016/j.inffus.2013.12.002
  3. Justin G. Schneeman, "Industrial X-ray Interpretation," Intex Publishing Company, 1968.
  4. Martin Hoheisel, "Review of medical imaging with emphasis on X-ray detectors," Nuclear Instruments and Methods in Physics Research, Vol. 563, No. 1, pp.215-224, 2006. https://doi.org/10.1016/j.nima.2006.01.123
  5. Alexander Flisch, Joachim Wirth, Robert Zanini, Michael Breitenstsin, Adrian Rudin, Florian Wendt, Franz Mnich, Roland Golz, "Industrial Computed Tomography in Reverse Engineering Applications," DGZ-fP-Proceedings BB, Vol. 4, No. 7, pp.45-53, 1999.
  6. Sunil K. Mathanker, Paul R. Weckler, Timothy J. Bowser, "X-Ray Applications in Food and Agriculture: A Review," Transactions of the ASABE, Vol. 56, No. 3, pp.1227-1239, 2013.
  7. Mario Pacheco, Deepak Goyal, "New Developments in High-Resolution X-ray Computed Tomography for Non- Destructive Defect Detection in Next Generation Package Technologies," International Symposium for Testing and Failure Analysis(ISTFA), pp.30-35, 2008.
  8. S. Rooks, T. Sack, "X-ray Inspection of Flip Chip Attach Using Digital Tomosynthesis," Journal of the Circuit World, Vol. 21, No. 3, pp.51-55, 1995.
  9. David Bernard, "X-ray tube selection criteria for BGA/CSP X-ray inspection," The Proceedings of SMTA International Conference, 2002.
  10. Jerrold T. Bushberg, J. Anthony Seibert, Edsin M. Leidholdt JR, John M. Boone, "The Essential Physics of Medical Imaging," Lippincott Willians & Wilkins, 2011.
  11. Jean-Marc Dinten, Christine Robert-Coutant, Michel Darboux, "Dual-energy X-rays absorptiometry using a 2D digital radiography detector: application to bone densitometry," SPIE Medical Imaging conference, pp.459-468, 2001.
  12. E. Gingold, B. Hasegawa, "Systematic bias in basis material decomposition applied to quantitative dual-energy x-ray imaging", Medical Physics, Vol. 19, No. 1, pp.25-33, 1992. https://doi.org/10.1118/1.596889
  13. Angelo Pietrobelli, Carmelo Formica, Zimian Wang, Steven B. Heymsfield, "Dual-energy X-ray absorptiometry body composition model: review of physical concepts," American Journal of Physiology-Endocrinology And Metabolism, Vol. 271, No. 6, pp.941-951, 1996. https://doi.org/10.1152/ajpendo.1996.271.6.E941