DOI QR코드

DOI QR Code

Shear Strength of Hairpin Reinforced Cast-In-Place Anchors by Static and Seismic Qualification Tests

헤어핀 보강 선설치앵커의 정적 및 지진모의실험에 의한 전단 저항강도 평가

  • Kim, Dong Hyun (Dept. of Civil Engineering, Pusan National University) ;
  • Park, Yong Myung (Dept. of Civil Engineering, Pusan National University) ;
  • Kim, Tae Hyung (Dept. of Civil Engineering, Pusan National University) ;
  • Jo, Sung Hoon (Dept. of Civil Engineering, Pusan National University) ;
  • Kang, Choong Hyun (School of Architectural and Civil Engineering, Kyungpook National University)
  • 김동현 (부산대학교, 토목공학과) ;
  • 박용명 (부산대학교, 토목공학과) ;
  • 김태형 (부산대학교, 토목공학과) ;
  • 조성훈 (부산대학교, 토목공학과) ;
  • 강충현 (경북대학교, 건축토목공학부)
  • Received : 2015.04.02
  • Accepted : 2015.06.02
  • Published : 2015.06.27

Abstract

This study evaluated the static and dynamic shear strength of cast-in-place anchors reinforced with hairpin bars in uncracked and cracked concrete. The anchors 30mm in diameter reinforced with D10 hairpin bar were designed with an edge distance of 150mm and an embedment depth of 240mm. The cracked specimens consisted of the orthogonal and parallel cracks to the direction of shear loads, respectively. The dynamic strength was evaluated using seismic qualification tests based on the ACI 355.2 standard. The shear strength of the hairpin reinforced anchor was hardly correlated to the concrete cracks and the dynamic strength was similar to its static shear strength. Finally, a consideration on the design strength of hairpin reinforced anchors was presented.

본 연구에서는 비균열 및 균열콘크리트에 설치된 헤어핀 보강 선설치앵커의 정적 및 동적 저항강도 평가를 위한 연구를 수행하였다. 이를 위해 앵커 직경 30mm, 연단거리 150mm, 매입깊이 240mm에 D10 헤어핀 철근으로 보강한 시험체를 제작하였으며, 균열시험체는 전단하중에 직각방향과 평행방향 균열을 각각 고려하였다. 동적 강도 평가는 지진모의실험에 의하였으며 가력방법은 ACI 355.2의 기준을 적용하였다. 헤어핀 보강 앵커의 저항강도는 콘크리트 균열과는 상관성이 없었으며 동적 강도는 정적 강도와 동등한 수준을 보였다. 마지막으로 헤어핀 보강 앵커의 설계 강도에 대한 고찰을 제시하였다.

Keywords

References

  1. ACI Committee 318-02 (2002) Building Code Requirements for Structural Concrete and Commentary, ACI 318-02, Appendix D: Anchoring to Concrete, American Concrete Institute.
  2. ACI Committee 318-11 (2011) Building Code Requirements for Structural Concrete and Commentary, Appendix D: Anchoring to Concrete, American Concrete Institute.
  3. ACI Committee 318-08 (2008) Building Code Requirements for Structural Concrete and Commentary, Appendix D: Anchoring to concrete, American Concrete Institute.
  4. Klingner, R.E., Mendonca, J.A., and Malik, J.B.(1982) Effect of Reinforcing Details on the Shear Resistance of Anchor Bolts Under Reversed Cyclic Loading, ACI Journal, Title No. 79-1, pp. 3-12.
  5. Lee, N.H., Park, K.R., and Suh, Y.P. (2010) Shear behavior of headed anchors with large diameters and deep embedments, ACI Structural Journal, Vol. 107, No. 4, pp. 146-156.
  6. 박용명, 강문기, 노진경, 주호중, 강충현(2014) 선설치앵커의 동적 전단하중에 대한 저항강도: 철근보강 앵커, 한국강구조학회논문집, 한국강구조학회, 제26권, 제1호, pp.21-31. (Park, Y.M., Kang, M.K., Roh, J.K., Ju, H.J., and Kang, C.H. (2014) Shear Resistance of CIP Anchors Under Dynamic Loading: Reinforced Anchor, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.1, pp.21-31 (in Korean).)
  7. Eligehausen, R., Mallee, R., and Silva, J.F. (2006) Anchorage in Concrete Construction, Ernst & Sohn, Germany.
  8. Gross, J.H., Klingner, R.E., and Graves III, H.L. (2001) Dynamic Anchor Behavior of Single and Double Near-Edge Anchors Loaded in Shear, Connections between Steel and Concrete (Int. Conference organized by University of Stuttgart, Co-sponsored by ACI, fib, IABSE, edited by R. Eligehausen), RILEM Publications S.A.R.L., pp.498-508.
  9. CSA N287.2 (1998) Material Requirements for Concrete Containment Structures for CANDU Nuclear Power Plants, Canadian Standards Association, Rexdale, Ontario.
  10. ACI 355.2 (2000) Evaluating the Performance of Post-installed Mechanical Anchors in Concrete, Reported by ACI Committee 355.
  11. ETAG 001(2013) Guideline for European Technical Approval of Metal Anchors for Use in Concrete, European Organization for Technical Approvals (EOTA).
  12. 박용명, 김태형, 김동현, 조성훈, 이종한(2015) 지진모의실험에 의한 비균열 및 균열콘크리트에 매입된 비보강 선설치앵커의 전단 저항강도 평가, 한국강구조학회논문집, 한국강구조학회, 제27권, 제3호, pp. 347-357. (Park, Y.M., Kim, T.H., Kim, D.H., Cho, S.H. and Lee, J.H. (2015) Shear Resistance of Unreinforced Cast-In-Place Anchors in Uncracked and Cracked Concrete by Seismic Qualification Tests, Journal of Korean Society of Steel Construction, KSSC. Vol.27, No.3, pp. 347-357.)
  13. 박용명, 주호중, 김동현, 강문기, 이종한(2015) 균열콘크리트에 매입된 선설치앵커의 정적 전단하중에 대한 저항강도, 한국강구조학회논문집, 한국강구조학회, 제27권, 제1호, pp.97-97. (Park, Y.M., Ju, H.J., Kim, D.H., Kang, M.K., and Lee, J.H. (2015) Static Shear Resistance of Cast-In-Place Anchors in Cracked Concrete, Journal of Korean Society of Steel Construction, KSSC, Vol.27, No.1, pp.87-97 (in Korean).)

Cited by

  1. Dynamic Shear Strength of Stirrup-reinforced Cast-in Anchors by Seismic Qualification Tests vol.30, pp.2, 2018, https://doi.org/10.7781/kjoss.2018.30.2.067