DOI QR코드

DOI QR Code

A Study on the Current Status and Improvement in Performing Flush-out in Multi-family Residential Buildings

공동주택에서의 플러쉬아웃 현황 및 개선방향을 위한 연구

  • Received : 2015.05.07
  • Accepted : 2015.08.17
  • Published : 2015.08.30

Abstract

Volatile organic compounds in buildings from finishing materials, adhesives, built-in furniture, etc. can cause headaches, atopic dermatitis, etc. for occupants in the buildings. To mitigate this, the Korean government has obligated to flush out the buildings after new construction and before occupancy since 2011. In this study, the current status of performing flush-out in multi-family residential buildings in Korea were analyzed, and its improvement would be proposed. At first, a questionnaire survey was conducted to figure out the current status of flush-out performances targeting a number of construction companies who have already constructed multi-family residential buildings with compliance of the obligation. Through the analysis of this survey, several conditions that need to be improved for flush-out were identified. Secondly, the identified conditions were evaluated in varying conditions using a simulation program to figure out an effective way of performing flush-out rather than as it is. As a result, a flush-out performance period with an appropriate supply air volume, and indoor temperature and humidity were identified to be improved through the survey, and it revealed through the simulation that the flush-out should be performed at least 14 days to reduce the indoor air pollution more than a half.

Keywords

Acknowledgement

Supported by : 국토교통과학기술진흥원

References

  1. ASHRAE. (2009). ASHRAE Standard 189.1-2009. American Society of Heating, Refrigerating and Air-Conditioning Enigeers.
  2. Choi, E. S., Kwon, K. W., & Park, J. S. (2008). The effect of temperature on VOCs' effective diffusion coefficients of building materials, Journal of Architectural Institute of Korea, 24(6), 371-378.
  3. HK-BEAM. (2004). Hong Kong Building Environmental Assessment Method Version 4/04. HK-BEAM Society.
  4. Jung, S. Y., Yoon, C. H., & Park, J. S. (2007). Long term variations of Formaldehyde and VOC's concentrations in an apartment finished by HB Mark Labelling building materials, Journal of Architectural Institute of Korea, 23(7), 277-287.
  5. KACA. Certification Criteria for HB Mark, Korea Air Cleaning Association.
  6. Kang, D. H., Choi, D. H., Kim, S. S., Kim, Y. D., Yeo, M. S., & Kim, K. W. (2006). A prediction of VOCs emission rate with temperature variation in floor heating space by numerical analysis, Korean Journal of Air-conditioning and Refrigeration Engineering, 18(6), 468-476.
  7. Kwon, K. W. (2007). A Study on Development of Indoor Air Quality Prediction Program for Multi-Zone. Thesis, Hanyang University.
  8. Kwon, K. W., Yoon, C. H., & Park, J. S. (2007). Prediction of VOCs emission rate from multi-layers finishing by using effective diffusion coefficients of single materials, Journal of Architectural Institute of Korea, 23(7), 269-276.
  9. Lee, Y. G. (2014). Highlights commentary on health-friendly housing construction standards, Journal of the Korean Association of Air Conditioning, refrigerating and Sanitary Engineers, 31(2), 65-74.
  10. ME. (2014). Indoor Air Regulation, Legislation No. 553, Ministry of Environment.
  11. MOLIT. (2013). Criteria for Health-friendly Housing Construction, Notice No. 2013-612, Ministry of Land, Infrastructure and Transport.
  12. USGBC. (2013). LEED Building Design and Construction v4.0. U.S. Green Building Council.