Abstract

This paper presents a current control strategy in the synchronous reference frame for a single-phase PWM converter, which ensures sinusoidal input current control under the distorted source voltage and frequency condition. Given that the distorted source voltage distorts the phase angle for PWM converter control, the input current contains the same harmonics as the source voltage. Aside from the distorted voltage, the variation in source frequency reduces the performance of input current control. To achieve sinusoidal input current control under the distorted source voltage and frequency condition, this paper proposes a compensation strategy of current reference with the distortion component extracted from the phase angle and a detection strategy of frequency variation from the output of a synchronous reference frame phase-lock loop. The experimental results confirm the validity of the proposed method under the distorted source voltage and frequency condition.

Keywords

References

  1. N. C. Park, H. S. Mok, J. K. Ji, and S. H. Kim, "Current compensation method of a three phase PWM converter under distorted source voltages," Transactions of Korean Institute of Power Electronics, Vol, 13, No. 5, pp. 352-359, Aug. 2008.
  2. N. C. Park, H. S. Mok, and S. H. Kim, "Reduction of input current harmonics for three phase PWM converter systems under a distorted utility voltage," Journal of Power Electronics, Vol. 10, No. 4, pp. 428-433, Jul. 2010. https://doi.org/10.6113/JPE.2010.10.4.428
  3. Liebert(R)GXT3TM 5000 & 6000VA RT230 Rack-Tower models Guide Specifications, Design Requirements, pp. 4-5, 2013.
  4. C. H. Ann and S. H. Kim, "The control of a single-phase PWM converter under a frequency variation in a power grid," Journal of Telecommunications and Information, Vol. 19, pp. 11-14, 2015.
  5. R. Zhang, M. Cardinal, P. Szczesny, and M. Dame, "A grid simulator with control of single-phase power converters in dq rotating frame," in Conf. Rec. IEEE PESC, pp. 1431-1436, 2002.
  6. S. H. Kim, Motor Control - DC, AC, BLDC, Ch. 7, Bogdoo, Aug. 2014.
  7. U. A. Miranda, L. Rolim, and M. Aredes, "A DQ synchronous reference frame current control for single-phase converters," in Conf. Rec. IEEE PESC, pp. 1377-1381, 2005.
  8. H. H. Hwang and J. W. Choi, "Performance improvement of single-phase PLL control using state observer," Transactions of Korean Institute of Power Electronics, Vol. 14, No. 2 pp. 96-104, Apr. 2009.
  9. S. J. Lee, J. G. Kang, and S. K. Sul, "A new phase detecting method for power conversion systems considering distorted conditions in power system," in Conf. Rec. IEEE IAS, pp. 2167-2172, 1999.