DOI QR코드

DOI QR Code

Amplitude dependency of damping of tall structures by the random decrement technique

  • Xu, An (State Key Laboratory of Subtropical Building Science, South China University of Technology) ;
  • Xie, Zhuangning (State Key Laboratory of Subtropical Building Science, South China University of Technology) ;
  • Gu, Ming (State Key Laboratory of Subtropical Building Science, South China University of Technology) ;
  • Wu, Jiurong (Engineering Technology Research and Development Center for Structural Wind Resistance and Health Monitoring in Guangdong Province, Guangzhou University)
  • Received : 2014.12.23
  • Accepted : 2015.05.25
  • Published : 2015.08.25

Abstract

This study focuses on the amplitude dependency of damping of tall structures by the random decrement technique (RDT). Many researchers have adopted RDT to establish the amplitude dependency of damping ratios in super-tall buildings under strong wind loads. In this study, a series of simulated examples were analyzed to examine the reliability of this method. Results show that damping ratios increase as vibration amplitudes increase in several cases; however, the damping ratios in the simulated signals were preset as constants. This finding reveals that this method and the derived amplitude-dependent damping ratio characteristics are unreliable. Moreover, this method would obviously yield misleading results if the simulated signals contain Gaussian white noise. Full-scale measurements on a super-tall building were conducted during four typhoons, and the recorded data were analyzed to observe the amplitude dependency of damping ratio. Relatively wide scatter is observed in the resulting damping ratios, and the damping ratios do not appear to have an obvious nonlinear relationship with vibration amplitude. Numerical simulation and field measurement results indicate that the widely-used method for establishing the amplitude-dependent damping characteristics of super-tall buildings and the conclusions derived from it might be questionable at the least. More field-measured data must be collected under strong wind loads, and the damping characteristics of super-tall buildings should be investigated further.

Keywords

References

  1. Aquino, R.E. and Tamura, Y. (2013), "Framework for structural damping predictor models based on stick-slip mechanism for use in wind-resistant design of buildings", J. Wind Eng. Ind. Aerod., 117, 25-37. https://doi.org/10.1016/j.jweia.2013.04.001
  2. Cele, M. (1996), "Comparison of damping in buildings under low-amplitude and strong motions", J. Wind Eng. Ind. Aerod., 59, 309-323. https://doi.org/10.1016/0167-6105(96)00014-1
  3. Cole, H.A. (1971), Method and apparatus for measuring the damping characteristics of a structure, United States Patent No. 3, 620, 069.
  4. Cole, H.A. (1968), "On-the-line analysis of random vibrations", AIAA Paper No. 68-288, AIAA/ASME Structures, Structural Dynamics and Material Conference, Palm Springs.
  5. Duda, K., Satake, N., Ono, J. and Sasaki, A. (1996), "Damping properties of buildings in Japan", J Wind Eng. Ind. Aerod., 59(2-3), 383-392. https://doi.org/10.1016/0167-6105(96)00018-9
  6. Davenport, A.G. and Carroll, H. (1986), Damping in tall buildings: its variability and treatment in design. ASCE Spring Convention, Seattle, 42-57.
  7. Fu, J.Y., Li, Q.S., Wu, J.R., Xiao, Y.Q. and Song, L.L. (2008), "Field measurements of Boundary layer wind characteristics and wind-induced responses of super-tall buildings", J. Wind Eng. Ind. Aerod., 96(8-9), 1332-1358. https://doi.org/10.1016/j.jweia.2008.03.004
  8. Fu, J.Y., Wu, J.R., Xu, A., Li, Q.S. and Xiao YQ. (2012), "Full-scale measurements of wind effects on Guangzhou West Tower", Eng. Struct., 35, 120-139. https://doi.org/10.1016/j.engstruct.2011.10.022
  9. Fukuwa, N., Nishizaka, R., Yagi, S., Tanaka, K. and Tamura, Y. (1996), "Field measurement of damping and natural frequency of an actual steel-framed building over a wide range of amplitudes", J. Wind Eng. Ind. Aerod., 59(2-3), 325-347. https://doi.org/10.1016/0167-6105(96)00015-3
  10. Holmes, J.D. (1978), "Computer simulation of multiple, correlated wind records using the inverse Fast Fourier Transform", Civil Eng. Trans., Institution of Engineers, Australia, 20(1), 67-74.
  11. AP. (1986), "Damping in tall buildings, a mechanism and a predictor", Earthq. Eng. Struct. D., 14(5), 750-773.
  12. Jeary, A.P. (1996), "The description and measurement of nonlinear damping in structures", J. Wind Eng. Ind. Aerod., 59(2-3), 103-114. https://doi.org/10.1016/0167-6105(96)00002-5
  13. Jeary, A.P. (1997), "Damping in structures", J. Wind Eng. Ind. Aerod., 72, 345-355. https://doi.org/10.1016/S0167-6105(97)00263-8
  14. Kareem, A. and Gurley, K. (1996), "Damping in structures: its evaluation and treatment of uncertainty", J. Wind Eng. Ind. Aerod., 59(2-3), 131-157. https://doi.org/10.1016/0167-6105(96)00004-9
  15. Li, Q.S., Fang, J.Q., Jeary, A.P. and Wong, C.K. (1998), "Full scale measurement of wind effects on tall buildings", J. Wind Eng. Ind. Aerod., 74-76, 741-750. https://doi.org/10.1016/S0167-6105(98)00067-1
  16. Li, Q.S., Liu, D.K., Fang, J.Q., Jeary, A.P. and Wong, C.K. (2000), "Damping in buildings: its neural network and AR model", Eng. Struct., 22(9), 1216-1223. https://doi.org/10.1016/S0141-0296(99)00050-4
  17. Li, Q.S., Yang, K., Wong, C.K. and Jeary, A.P. (2003), "The effect of amplitude-dependent damping on wind-induced vibrations of a super tall building", J. Wind Eng. Ind. Aerod., 91(9), 1175-1198. https://doi.org/10.1016/S0167-6105(03)00080-1
  18. Li, Q.S., Xiao, Y.Q., Wong, C.K. and Jeary, A.P. (2004), "Field measurements of typhoon effects on a super tall building", Eng. Struct., 26(2), 233-244. https://doi.org/10.1016/j.engstruct.2003.09.013
  19. Li, Q.S., Xiao, Y.Q., Fu, J.Y. and Li, Z.N. (2007), "Full-scale measurements of wind effects on the Jin Mao Building", J. Wind Eng. Ind. Aerod., 95(6), 445-466. https://doi.org/10.1016/j.jweia.2006.09.002
  20. Li, Q.S., Xiao, Y.Q., Wu, J.R., Fu, J.Y. and Li, Z.N. (2008), "Typhoon effects on super-tall buildings", J Sound Vib., 313(3-5), 581-602. https://doi.org/10.1016/j.jsv.2007.11.059
  21. Li, Q.S., Wu, J.R., Fu, J.Y., Li, Z.N. and Xiao, Y.Q. (2009), "Wind effects on the world's tallest reinforced concrete building", Struct. Build., 163(2), 97-110.
  22. Tamura, Y. and Suganuma, K. (1996), "Evaluation of amplitude-dependent damping and natural frequency of buildings during strong winds", J Wind Eng. Ind. Aerod., 59(2-3), 115-130 https://doi.org/10.1016/0167-6105(96)00003-7
  23. Tamura, Y. (2012), "Amplitude dependency of damping in buildings and critical tip drift ratio", Int. J. High-Rise Build., 1, 1-13.
  24. Wu, J.R., Liu, P.F. and Li, Q.S. (2007), "Effects of amplitude-dependent damping and time constant on wind-induced responses of super tall building", Comput. Struct., 85(15-16), 1165-1176 https://doi.org/10.1016/j.compstruc.2007.01.012
  25. Yi, J, Zhang, J.W., and Li, Q.S. (2013), "Dynamic characteristics and wind-induced responses of a super-tall building during typhoons", J Wind Eng. Ind. Aerod., 121, 116-130. https://doi.org/10.1016/j.jweia.2013.08.006

Cited by

  1. Lateral drift constrained structural optimization of an actual supertall building acted by wind load vol.26, pp.6, 2017, https://doi.org/10.1002/tal.1344
  2. Wind effects on Shenzhen Zhuoyue Century Center: Field measurement and wind tunnel test vol.26, pp.13, 2017, https://doi.org/10.1002/tal.1376
  3. Experimental study of wind effects on two neighboring super-tall buildings vol.21, pp.3, 2018, https://doi.org/10.1177/1369433217723411
  4. Evaluation of Wind-Induced Response Bounds of High-Rise Buildings Based on a Nonrandom Interval Analysis Method vol.2018, pp.1875-9203, 2018, https://doi.org/10.1155/2018/3275302
  5. Model shape correction method for high-frequency force balance technique vol.19, pp.3, 2015, https://doi.org/10.21595/jve.2017.17938
  6. Impact of a Fifty-Year-Recurrence Super Typhoon on Skyscrapers in Hong Kong: Large-Scale Field Monitoring Study vol.147, pp.3, 2021, https://doi.org/10.1061/(asce)st.1943-541x.0002930
  7. Investigation of time-varying structural dynamic properties of high-rise buildings under typhoon conditions vol.46, pp.None, 2022, https://doi.org/10.1016/j.jobe.2021.103796