참고문헌
- C. Cabassud, S. Laborie, and J. M. Laine, "How to slug flow can improve ultrafiltration flux in organic hollow fibers", J. Membr. Sci., 128, 93 (1997). https://doi.org/10.1016/S0376-7388(96)00316-X
- M. Bonin, C. Lagane, and C. Fonade, "Influence of a gas/liquid teo-phase flow on the ultrafiltration and microfiltration performances: case of a ceramic flat sheet membrane", J. Membr. Sci., 180, 93 (2000). https://doi.org/10.1016/S0376-7388(00)00520-2
- M. Mercier, C. Fonade, and C. Lafforgue-Delorme, "How to slug flow can enhance the ultrafiltration flix in mineral tubular membranes", J. Membr. Sci., 128, 103 (1997). https://doi.org/10.1016/S0376-7388(96)00317-1
- O. S. Kwon, H. S. Yoon, Y. K. Choi, and S. H. Noh, "Variation of superficial velocity of a submerged module (YEF) by module size and aerator type", Desalination, 233, 319 (2008). https://doi.org/10.1016/j.desal.2007.09.057
- T. Ueda, K. Hata, Y. Kikuoka, and O. Seino, "Effect of aeration on suction pressure in a submerged membrane bioreactor", Wat. Res., 31, 489 (1997). https://doi.org/10.1016/S0043-1354(96)00292-8
- R. Liu, C. Wang, L. Chen, and Y. Qian, "Study on hydrauric characteristics in a submerged membrane bioreactor process", Process Biochemistry, 36, 249 (2000). https://doi.org/10.1016/S0032-9592(00)00210-7
- L. Vera, R. Villarroel, S. Delgado, and S. Elmaleh, "Enhancing microfiltration through an inorganic tubulrar membrane by gas sparging", J. Membr. Sci., 165, 47 (2000). https://doi.org/10.1016/S0376-7388(99)00216-1
- A. Sofia, W. J. Ng, and S. L. Ong, "Enhancing design approaches for minimum fouling in submerged MBR", Desalination, 160, 67 (2004). https://doi.org/10.1016/S0011-9164(04)90018-5
- H. Prieske, A. Drews, and M. Kraume, "Prediction of the circulation velocity in a membrane bioreactor", Desalination, 231, 219 (2008). https://doi.org/10.1016/j.desal.2007.12.010
- I. H. Won, D. C. Kim, and K. Y. Chung, "Transmembrane Pressure of the Sinusoidal Flux Continuous Operation Mode for the Submerged Flat-sheet Membrane Bioreator in Coagulation Dosage", Membr. J., 25, 7 (2015). https://doi.org/10.14579/MEMBRANE_JOURNAL.2015.25.1.7
- J. H. Kim and F. A. DiGiano, "Defining critical flux in submerged membrane: Influence of length-distributed flux", J. Membr. Sci., 280, 752 (2006). https://doi.org/10.1016/j.memsci.2006.02.040
- S. Chang and A. G. Fane, "The effect of fiber diameter on filtration and flux distribution-relevence to submerged hollow fiber modules", J. Membr. Sci., 184, 221 (2001). https://doi.org/10.1016/S0376-7388(00)00626-8
- Z. F. Cui, S. Chang, and A. G. Fane, "The use of gas bubbling to enhance membrane process", J. Membr. Sci., 221, 1 (2003). https://doi.org/10.1016/S0376-7388(03)00246-1
- Y. K. Choi, C. S. Kim, M. S. Cho, O. S. Kwon, S. H. Noh, H. W. Hur, S. K. Park, K. H.Yeon, S. D. Yoon, and I. H. Yeo, "Effect of the aeration rate on the water velocity distribution in submerged hollow fiber modules", Proceedings of AMS5 Conference, Kobe, Japan (2009).
- C. Cabassud, S. Laborie, L. Durand-Bourlier, and J. M. Laine, "Air sparging in ultrafiltration hollow fibers: relationship between flux enhancement, cake characteristics any hydrodynamic parameters", J. Membr. Sci., 181, 57 (2001). https://doi.org/10.1016/S0376-7388(00)00538-X
- D. Pfleger, S. Gomes, N. Gibert, and H.-G. Wagner, "Hydrodynamic simulations of laboratory scale bubble columns fundamental studies of Eulerian-Eulerian modeling approach", Chem. Eng. Sci., 54, 5091 (1999). https://doi.org/10.1016/S0009-2509(99)00261-4
- P. Spicka, M. M. Dias, and J. C. B. Lopes, "Gas-liquid flow in a 2D column: Comparison between experimental data and CFD modeling", Chem. Eng. Sci., 56, 6367 (2001). https://doi.org/10.1016/S0009-2509(01)00276-7
- E. N. C. Duc, L. Fournier, C. Levecq, B. Lesjean, P. Grelier, and A. Tazi-Pain, "Local hydrodynamic investigation of the aeration in a submerged hollow fibre membrane cassette", J. Membr. Sci., 312, 264 (2008).
- M. Simmonet, C. Gentric, E. Olmos, and N. Midoux, "Experimental determination of the drag coefficient in a swarm of bubbles", Chem. Eng. Sci., 62, 858 (2007). https://doi.org/10.1016/j.ces.2006.10.012
- J. Lin, M. Han, T. Wang, T. Zhang, J. Wang, and Y. Jin, "Influence of the gas distributor on the local hydrodynamic behavior of an external loop airlift reactor", Chem. Eng. J., 102, 51 (2004). https://doi.org/10.1016/j.cej.2004.01.023
- M. Cheryan, "Ultrafiltration and Microfiltration Handbook", Technomic Publishing (1998).
- M. Mercier, C. Fonade, and C. Lafforgue-Delorme, "Influence of flow regime on the efficiency of a gas-liquid two-phase medium filtration", Biotech. Techniques, 9, 853 (1995). https://doi.org/10.1007/BF00158535
- N. V. Ndinisa, D. E. Wiley, and D. F. Fletcher, "Computational fluid dynamics simulations of taylor bubbles in tubular membrane-Model validation and application to laminar flow system", Chem. Eng. Res. & Design, 83, 40 (2005). https://doi.org/10.1205/cherd.03394
- N. V. Ndinisa, A. G. Fane, D. E. Wiley, and D. F. Fletcher, "Fouling control in a submerged flat membrane system: Part II-Two-phase flow characterization and CFD simulations", Sep. Sci. Tech., 41, 1411 (2006). https://doi.org/10.1080/01496390600633915
- J. H. Kim and F. A. DiGiano, "Particle fouling in submerged microfiltration membranes: effects of hollow-fiber length and aeration rate", AQUA, 55, 535 (2006).
- I. S. Chang, P. Le Clech, B. Jefferson, and S. Jude, "Membrane fouling in membrane bioreactors for wastewater treatment", J. Environ. Eng., 128, 1018 (2002). https://doi.org/10.1061/(ASCE)0733-9372(2002)128:11(1018)