References
- Sonntag D, Guntermann A, Kim SK, Stachniss V. Root canal shaping with manual stainless steel files and rotary Ni-Ti files performed by students. Int Endod J 2003;36:246-255. https://doi.org/10.1046/j.1365-2591.2003.00661.x
- Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod 2000;26:161-165. https://doi.org/10.1097/00004770-200003000-00008
- Alapati SB, Brantley WA, Svec TA, Powers JM, Nusstein JM, Daehn GS. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical Use. J Endod 2005;31:40-43.
- Berutti E, Negro AR, Lendini M, Pasqualini D. Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments. J Endod 2004;30:228-230. https://doi.org/10.1097/00004770-200404000-00011
- Patino PV, Biedma BM, Liebana CR, Cantatore G, Bahillo JG. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod 2005;31:114-116.
- Ha JH, Park SS. Influence of glide path on the screwin effect and torque of nickel-titanium rotary files in simulated resin root canals. Restor Dent Endod 2012;37: 215-219. https://doi.org/10.5395/rde.2012.37.4.215
- Ruddle CJ. The ProTaper technique. Endod Top 2005;10:187-190. https://doi.org/10.1111/j.1601-1546.2005.00115.x
- West J. Endodontic update 2006. J Esthet Restor Dent 2006;18:280-300. https://doi.org/10.1111/j.1708-8240.2006.00039.x
- Ruddle CJ. Cleaning and shaping the root canal system. In: Cohen S, Burn RC, eds. Pathway of the pulp, 8th ed. St. Louis, MO: Mosby Elsevier; 2002. p231-292.
- Bahcall JK, Carp S, Miner M, Skidmore L. The causes, prevention, and clinical management of broken endodontic rotary files. Dent Today 2005;24:74-80.
- Lopes HP, Elias CN, Siqueira JF Jr, Soares RG, Souza LC, Oliveira JC, Lopes WS, Mangelli M. Mechanical behavior of pathfinding endodontic instruments. J Endod 2012; 38:1417-1421. https://doi.org/10.1016/j.joen.2012.05.005
- Yun HH, Kim SK. A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003;95:228-233. https://doi.org/10.1067/moe.2003.92
- Park H. A comparison of Greater Taper files, ProFiles, and stainless steel files to shape curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2001; 91:715-718. https://doi.org/10.1067/moe.2001.114159
- Arens FC, Hoen MM, Steiman HR, Dietz GC Jr. Evaluation of single-use rotary nickel titanium instruments. J Endod 2003;29:664-666. https://doi.org/10.1097/00004770-200310000-00013
- Cheung GSP. Instrument fracture: mechanisms, removal of fragments, and clinical outcomes. Endod Top 2007; 16:1-26. https://doi.org/10.1111/j.1601-1546.2009.00239.x
- West JD. The endodontic Glidepath: “Secrets to rotary safety”. Dent Today 2010;29:86-93.
- Blum JY, Machtou P, Ruddle C, Micallef JP. Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: value of the safety quotient. J Endod 2003;29:567-575. https://doi.org/10.1097/00004770-200309000-00007
- Peters OA, Peters CI, Schönenberger K, Barbakow F. ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by micro CT. Int Endod J 2003;36:86-92. https://doi.org/10.1046/j.1365-2591.2003.00626.x
- Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G, Pasqualini D. Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Endod 2009;35:408-412. https://doi.org/10.1016/j.joen.2008.11.021
- Wu MK, Roris A, Bakis D, Wesselink PR. Prevalence and extent of long oval canals in the apical third. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000;89:739-743. https://doi.org/10.1067/moe.2000.106344
- Burklein S, Tsotsis P, Schafer E. Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation. J Endod 2013;39:501-504 https://doi.org/10.1016/j.joen.2012.11.045
Cited by
- Effective Establishment of Glide-Path to Reduce Torsional Stress during Nickel-Titanium Rotary Instrumentation vol.12, pp.3, 2019, https://doi.org/10.3390/ma12030493