참고문헌
- Ng YL, Mann V, Rahbaran S, Lewsey J, Gulabivala K. Outcome of primary root canal treatment: systematic review of the literature - Part 2. Influence of clinical factors. Int Endod J 2008;41:6-31.
- Ng YL, Mann V, Rahbaran S, Lewsey J, Gulabivala K. Outcome of primary root canal treatment: systematic review of the literature - part 1. Effects of study characteristics on probability of success. Int Endod J 2007;40:921-939. https://doi.org/10.1111/j.1365-2591.2007.01322.x
- Smith CS, Setchell DJ, Harty FJ. Factors influencing the success of conventional root canal therapy-a five-year retrospective study. Int Endod J 1993;26:321-333. https://doi.org/10.1111/j.1365-2591.1993.tb00765.x
- ElAyouti A, Weiger R, Lost C. Frequency of overinstrumentation with an acceptable radiographic working length. J Endod 2001;27:49-52.
- Kim E, Lee SJ. Electronic apex locator. Dent Clin North Am 2004;48:35-54. https://doi.org/10.1016/j.cden.2003.10.005
- Sunada I. New method for measuring the length of the root canal. J Dent Res 1962;41:375-387. https://doi.org/10.1177/00220345620410020801
- Inoue N, Skinner DH. A simple and accurate way to measuring root canal length. J Endod 1985;11:421-427. https://doi.org/10.1016/S0099-2399(85)80079-0
- Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J Endod 1994;20: 111-114. https://doi.org/10.1016/S0099-2399(06)80053-1
- Nekoofar MH, Ghandi MM, Hayes SJ, Dummer PM. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 2006;39:595-609. https://doi.org/10.1111/j.1365-2591.2006.01131.x
- Gomes S, Oliver R, Macouzet C, Mercadé M, Roig M, Duran-Sindreu F. In vivo evaluation of the Raypex 5 by using different irrigants. J Endod 2012;38:1075-1077. https://doi.org/10.1016/j.joen.2012.05.018
- Stober EK, Duran-Sindreu F, Mercade M, Vera J, Bueno R, Roig M. An evaluation of root ZX and iPex apex locators: an in vivo study. J Endod 2011;37:608-610. https://doi.org/10.1016/j.joen.2011.02.002
- Stober EK, de Ribot J, Mercade M, Vera J, Bueno R, Roig M, Duran-Sindreu F. Evaluation of the Raypex 5 and the Mini Apex Locator: an in vivo study. J Endod 2011;37: 1349-1352. https://doi.org/10.1016/j.joen.2011.06.021
- Duran-Sindreu F, Stober E, Mercade M, Vera J, Garcia M, Bueno R, Roig M. Comparison of in vivo and in vitro readings when testing the accuracy of the Root ZX apex locator. J Endod 2012;38:236-239. https://doi.org/10.1016/j.joen.2011.10.008
- Meredith N, Gulabivala K. Electrical impedance measurements of root canal length. Endod Dent Traumatol 1997;13:126-131. https://doi.org/10.1111/j.1600-9657.1997.tb00025.x
- Krizaj D, Jan J, Valencic V. Modeling AC current conduction through a human tooth. Bioelectromagnetics 2004;25:185-195. https://doi.org/10.1002/bem.10189
- Al-bulushi A, Levinkind M, Flanagan M, Ng YL, Gulabivala K. Effect of canal preparation and residual root filling material on root impedance. Int Endod J 2008;41:892-904. https://doi.org/10.1111/j.1365-2591.2008.01450.x
- Levinkind M. A dental application of neural network computing: classification of complex electrical impedance measurements to aid root canal treatment. Neural Comput Applic 1994;2:209-215. https://doi.org/10.1007/BF01414809
- Huang JH, Yen SC, Lin CP. Impedance characteristics of mimic human tooth root canal and its equivalent circuit model. J Electrochem Soc 2008;155:51-56.
- Pilot TF, Pitts DL. Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant. J Endod 1997;23:719-724. https://doi.org/10.1016/S0099-2399(97)80341-X
- Perdikaris GA. Computer controlled systems: theory and applications. Netherlands: Kluwer Academic Publisher; 1991. p116-118.
- Oishi A, Yoshioka T, Kobayashi C, Suda H. Electronic detection of root canal constrictions. J Endod 2002;28: 361-364. https://doi.org/10.1097/00004770-200205000-00003
- Lee SJ, Kim DW, Nam KC. Development of new frequency-dependent type apex locator: voltage difference compensating type. J Korean Acad Conserv Dent 1997; 22:809-819.
- Gordon MP, Chandler NP. Electronic apex locators. Int Endod J 2004;37:425-437. https://doi.org/10.1111/j.1365-2591.2004.00835.x
- Nilsson JW, Riedel SA. Electric circuits. 5th ed. Reading, MA: Addison-Wesley; 1996. p221-222.
- Nelson-Filho P, Romualdo PC, Bonifacio KC, Leonardo MR, Silva RA, Silva LA. Accuracy of the iPex multifrequency electronic apex locator in primary molars: an ex vivo study. Int Endod J 2011;44:303-306. https://doi.org/10.1111/j.1365-2591.2010.01827.x
- Rambo MV, Gamba HR, Ratzke AS, Schneider FK, Maia JM, Ramos CA. In vivo determination of the frequency response of the tooth root canal impedance versus distance from the apical foramen. Conf Proc IEEE Eng Med Biol Soc 2007;2007:570-573.
- Rambo MV, Gamba HR, Borba GB, Maia JM, Ramos CA. In vivo assessment of the impedance ratio method used in electronic foramen locators. Biomed Eng Online 2010;9:46. https://doi.org/10.1186/1475-925X-9-46
- Jan J, Krizaj D. Accuracy of root canal length determination with the impedance ratio method. Int Endod J 2009;42:819-826. https://doi.org/10.1111/j.1365-2591.2009.01589.x
피인용 문헌
- evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files vol.41, pp.1, 2016, https://doi.org/10.5395/rde.2016.41.1.6