Abstract

Wind tunnel testing of a low-rise building with openings (holes) of different sizes and shapes on a roof corner is conducted to measure the internal and external pressures from the building model. Detailed analysis of the testing data is carried out to investigate the characteristics of the internal and external pressures of the building with different openings' configurations. Superimposition of the internal and external pressures makes the emergence of positive net pressures on the roof. The internal pressures demonstrate an overall uniform distribution. The probability density function (PDF) of the internal pressures is close to the Gaussian distribution. Compared with the PDF of the external pressures, the non-Gaussian characteristics of the net pressures weakened. The internal pressures exhibit strong correlation in frequency domain. There appear two humps in the spectra of the internal pressures, which correspond to the Helmholtz frequency and vortex shedding frequency, respectively. But, the peak for the vortex shedding frequency is offset for the net pressures. Furthermore, the internal pressure characteristics indirectly reflect that the length of the front edge enhances the development of the conical vortices.The objective of this study aims to further understanding of the characteristics of internal, external and net pressures for low-rise buildings in an effort to reduce wind damages to residential buildings.

Keywords

Acknowledgement

Supported by : Hunan University, National Natural Science Foundation of China, City University of Hong Kong

References

  1. Blocken, B. and Persoon, J. (2009), "Pedestrian wind comfort around a large football stadium in an urban environment: CFD simulation, validation and application of the new Dutch wind nuisance standard", J. Wind Eng. Ind. Aerod., 97(5-6), 255-270. https://doi.org/10.1016/j.jweia.2009.06.007
  2. GB50009-2012(2012), Load code for the design of building structures, China Architecture & Building Press, Beijing.
  3. Ginger, J.D., Mehta, K.C. and Yeatts, B.B. (1997), "Internal pressures in a low-rise full-scale building", J. Wind Eng. Ind. Aerod., 72, 163-174. https://doi.org/10.1016/S0167-6105(97)00241-9
  4. Guha, T.K., Sharma, R.N. and Richards, P.J. (2011), "Internal pressure dynamics of a leaky building with a dominant opening", J. Wind Eng. Ind. Aerod., 99(11), 1151-1161. https://doi.org/10.1016/j.jweia.2011.09.002
  5. Holmes, J.D. and Ginger, J.D. (2012),"Internal pressures - The dominant windward opening case - Areview", J. Wind Eng. Ind. Aerod., 100(1), 70-76. https://doi.org/10.1016/j.jweia.2011.11.005
  6. Holmes, J.D. (1979), "Mean and fluctuating internal pressures induced by wind", Proceedings of the 5th Int. Conf. Wind Eng..
  7. Huang, P. and Gu, M. (2004),"Experimental study and comparison analysis on wind load of a large span cantilever roof", J. Struct. Eng.-ASCE, 20(4), 51-55.
  8. Kawai, H. (2002), "Local peak pressureand conical vortex on building", J. Wind Eng. Ind. Aerod., 90(4-5), 251-263. https://doi.org/10.1016/S0167-6105(01)00218-5
  9. Kopp, G.A. and Morrison, M.J. (2012), "Full-scale testing of low-rise, residential buildings with realistic wind loads", J. Wind Eng. Ind. Aerod., 104-106, 25-39. https://doi.org/10.1016/j.jweia.2012.01.004
  10. Li, Q.S., Dai,Y.M. and Li, Z.N. (2010), "Wind pressures on low-rise building surface during a severe typhoon 'Hagupit'", J. Build. Struct., 31(4), 62-68.
  11. Li, Q.S., Hu, S.Y., Dai Y.M. and Li Z.N. (2010), "Analysis of the field measured suction peak pressure coefficients on a flat roof of a low-rise building", J. Hunan Univ., 37(6), 11-16.
  12. Li, Q.S., Hu, S.Y., Dai, Y.M. and He, Y.C. (2012), "Field measurements of extreme pressures on a flat roof of a low-rise building during typhoons", J. Wind Eng. Ind. Aerod., 111(12), 14-29. https://doi.org/10.1016/j.jweia.2012.08.003
  13. Liu, H. and Saathoff, P.J. (1981), "Building internal pressure: sudden change", J. Eng. Mech. Div., 107(2), 309-321.
  14. Mahmood, M. (2011), "Experiments to study turbulence and flow past a low-rise building at oblique incidence", J. Wind Eng. Ind. Aerod., 99(5), 560-572. https://doi.org/10.1016/j.jweia.2011.02.005
  15. Matsumoto, M., Shirato, H., Aaraki, K., Haramura, T. and Hashimoto, T. (2003), "Spanwise coherence characteristic of surface pressure field on 2D bluff bodies", J. Wind Eng. Ind. Aerod., 91(1-2), 155-163. https://doi.org/10.1016/S0167-6105(02)00342-2
  16. Pan, F., Cai, C.S. and Zhang, W. (2013), "Wind-induced internal pressures of buildings with multiple openings", J. Eng. Mech - ASCE., 139, 376-385. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000464
  17. Sharma, R.N. (2013), "Internal and net proof pressures for a dynamically flexible building with a dominant wall opening", Wind Struct., 16(1), 93-115. https://doi.org/10.12989/was.2013.16.1.093
  18. Sharma, R.N. and Richards, P.J. (2003), "The influence of Helmholtz resonance on internal pressures in a low-rise building", J. Wind Eng. Ind. Aerod., 91(6), 807-828 https://doi.org/10.1016/S0167-6105(03)00005-9
  19. Stathopoulos, T. and Luchian, H.D. (1989), "Transient wind-induced internal pressure", J Eng. Mech.-ASCE, 115(7), 1501-1513. https://doi.org/10.1061/(ASCE)0733-9399(1989)115:7(1501)
  20. Tecle, A.S., Bitsuamlak, G.T. and Aly, A.M., (2013), "Internal pressure in a low-rise building with existing envelope openings and sudden breaching", Wind Struct, 16(1), 25-46. https://doi.org/10.12989/was.2013.16.1.025
  21. Tecle, A.S., Bitsuamlak, G.T., Suskawang, N., Chowdury, A.G. and Fuez, S. (2013), "Ridge and field tile aerodynamics for a low-rise building: a full-scale study", Wind Struct., 16(4), 301-322. https://doi.org/10.12989/was.2013.16.4.301
  22. Van de Lindt, J.W., Graettinger, A., Gupta, R., Skaggs, T., Pryor, S. and Fridley, K.J. (2007), "Performance of wood-frame structures during Hurricane Katrina", J. Perf. Constr. Facil., 21(2), 108-116. https://doi.org/10.1061/(ASCE)0887-3828(2007)21:2(108)
  23. Vickery, B.J. and Bloxham, C. (1992), "Internal pressure dynamics with a dominant opening", J. Wind Eng. Ind. Aerod., 41(1-3), 193-204. https://doi.org/10.1016/0167-6105(92)90409-4
  24. Woods, A.R. and Blackmore, P.A. (1995), "The effect of dominant openings and porosity on internal pressures", J. Wind Eng. Ind. Aerod., 57(2-3), 167-177. https://doi.org/10.1016/0167-6105(95)00003-A
  25. Wu, F.Q. (2000), Full-scale study of conical vortices and their effects near roof corners, PhD Thesis, Texas Tech University, Texas.
  26. Zhao, Z.S. (1997), Wind flow characteristics and their effects on low-rise buildings, PhD Thesis, Texas Tech University, Texas.

Cited by

  1. A review of wood-frame low-rise building performance study under hurricane winds vol.141, 2017, https://doi.org/10.1016/j.engstruct.2017.03.036
  2. Fragility Assessment of Roof-to-Wall Connection Failures for Wood-Frame Houses in High Winds vol.3, pp.4, 2017, https://doi.org/10.1061/AJRUA6.0000916
  3. Wind pressures on different roof shapes of a finite height circular cylinder vol.24, pp.1, 2015, https://doi.org/10.12989/was.2017.24.1.025
  4. An engineering-based assessment methodology on the loss of residential buildings under wind hazard vol.30, pp.1, 2015, https://doi.org/10.12989/was.2020.30.1.001
  5. Natural wind impact analysis of transiting test method to measure wind pressure coefficients vol.30, pp.2, 2020, https://doi.org/10.12989/was.2020.30.2.199
  6. Steady-state and transient wind characteristics of low-rise building roofs with openings in vulnerable areas vol.23, pp.11, 2015, https://doi.org/10.1177/1369433220911116
  7. Experimental and theoretical study on the internal pressure induced by the transient local failure of low-rise building roofs vol.24, pp.14, 2015, https://doi.org/10.1177/13694332211022069